The degradation profile of novel, bioresorbable PCL–TCP scaffolds: An in vitro and in vivo study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Degradation studies of scaffolds are important in bone tissue engineering. Previously, novel poly(ε‐caprolactone)–20% tricalcium phosphate (PCL–TCP) based scaffolds were developed and proven useful for bone regeneration. In this study in vitro degradation analyses were carried out with the PCL–TCP scaffolds immersed in standard culture medium for 24 weeks. In vivo degradation was performed with the scaffolds implanted in the abdomen of rats for the same period of time. Results demonstrated greater degradation of PCL–TCP scaffolds in vivo than in vitro. At 24 weeks, the increase of average porosity of the scaffolds in vivo was 29.2% compared to 2.65% in vitro. Gel permeation chromatography (GPC) analysis revealed a decrease of 29% and 20% respectively in the Mn and Mw values after 24 weeks in vitro. However, a significant decrease in Mn and Mw values (79.6% and 88.7% respectively) were recorded in vivo. The mechanical properties however, were relatively similar and closely match those of cancellous bone even at 24 weeks. The results showed that the scaffold can be used for dentoalveolar reconstruction and PCL–TCP scaffolds have shown to possess the potential to degrade within the desired time period of 5–6 months and favorable mechanical properties. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis
Sung, H.-J., Meredith, C., Johnson, C., & Galis, Z. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.066 · Cited by 804
Cited by
Bone tissue engineering: A review in bone biomimetics and drug delivery strategies
Porter, J. R., Ruckh, T. T., & Popat, K. C. (2009) · Biotechnology Progress · doi:10.1002/btpr.246 · Cited by 809
Degradation mechanisms of polycaprolactone in the context of chemistry, geometry and environment
Bartnikowski, M., Dargaville, T. R., Ivanovski, S., & Hutmacher, D. W. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.05.004 · Cited by 769
Chuenjitkuntaworn, B., Inrung, W., Damrongsri, D., Mekaapiruk, K., Supaphol, P., & Pavasant, P. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32657 · Cited by 197
Bruyas, A., Lou, F., Stahl, A. M., Gardner, M., Maloney, W., Goodman, S., & Yang, Y. P. (2018) · Journal of Materials Research · doi:10.1557/jmr.2018.112 · Cited by 173
“degradation protocol.(16,23,24) It is thought that polyester degradation under these conditions mimics typical degradation under aqueous conditions where ester–ester linkages are hydrolytically severed, breaking apart the bulk material.”
BackgroundMethodVyas, C., Zhang, J., Øvrebø, Ø., Huang, B., Roberts, I., Setty, M., Allardyce, B., Haugen, H., Rajkhowa, R., & Bartolo, P. (2021) · Materials Science and Engineering: C · doi:10.1016/j.msec.2020.111433 · Cited by 111
Metadata
- Authors
- Yeo, A., Rai, B., Sju, E., Cheong, J. J., & Teoh, S. H.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-07-02
- Volume
- 84A
- Issue
- 1
- Pages
- 208-218
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2011412003
- Cited by
- 135
- References
- 1
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.