Fibrous capsule formation around titanium and copper
The DOI matches its Crossref record.
Abstract
Previous studies suggest that implant material properties influence the quality and quantity of fibrous capsule around the implant. However, the precise relation between material surface chemistry, early inflammatory response, and fibrous subsequent repair outcome is still unknown. Titanium (Ti) and copper (Cu), surfaces with different inflammatory potential, were implanted subcutaneously in rats and retrieved fibrous capsules were analyzed after 28 and 56 days. Histological examinations show pronounced differences in capsule morphology. The fibrous capsule around Ti was thinner than that around Cu, with less number of the inflammatory cells in the layer close to the implant surface, and less and smaller blood vessels. The capsule around Cu was thick, with a large number of the inflammatory cells, particularly macrophages and giant cells, and increased number of blood vessels. Our study suggests that material surface properties, which initiate early, multiple cellular inflammatory events, are also associated with increased fibrosis and angiogenesis during repair phase. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanotopographical modification: a regulator of cellular function through focal adhesions
Biggs, M. J. P., Richards, R. G., & Dalby, M. J. (2010) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2010.01.009 · Cited by 466
On osseointegration in relation to implant surfaces
Albrektsson, T., & Wennerberg, A. (2019) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12742 · Cited by 361
Chronic interfacing with the autonomic nervous system using carbon nanotube (CNT) yarn electrodes
McCallum, G. A., Sui, X., Qiu, C., Marmerstein, J., Zheng, Y., Eggers, T. E., Hu, C., Dai, L., & Durand, D. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-10639-w · Cited by 102
Ben Amara, H., Martinez, D. C., Shah, F. A., Loo, A. J., Emanuelsson, L., Norlindh, B., Willumeit-Römer, R., Plocinski, T., Swieszkowski, W., Palmquist, A., et al. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.02.014 · Cited by 42
“area and distance to the tissue/implant interface were measured on the superficial, deep and lateral sides of the implant as previously described [41]; 3-Mast cells were identified in the fascia underneath the panniculus carnosus on the superficial, deep, and lateral sides of the implants.”
BackgroundMethodSelf-citationKundu, A., Wirenfeldt, M., Harreby, K. R., & Jensen, W. (2014) · The International Journal of Artificial Organs · doi:10.5301/ijao.5000342 · Cited by 15
Metadata
- Authors
- Suska, F., Emanuelsson, L., Johansson, A., Tengvall, P., & Thomsen, P.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-09-26
- Volume
- 85A
- Issue
- 4
- Pages
- 888-896
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2095285720
- Cited by
- 68
- References
- 0
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.