The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Chronic interfacing with the autonomic nervous system using carbon nanotube (CNT) yarn electrodes
Open accessAbstract
The ability to reliably and safely communicate chronically with small diameter (100–300 µm) autonomic nerves could have a significant impact in fundamental biomedical research and clinical applications. However, this ability has remained elusive with existing neural interface technologies. Here we show a new chronic nerve interface using highly flexible materials with axon-like dimensions. The interface was implemented with carbon nanotube (CNT) yarn electrodes to chronically record neural activity from two separate autonomic nerves: the glossopharyngeal and vagus nerves. The recorded neural signals maintain a high signal-to-noise ratio (>10 dB) in chronic implant models. We further demonstrate the ability to process the neural activity to detect hypoxic and gastric extension events from the glossopharyngeal and vagus nerves, respectively. These results establish a novel, chronic platform neural interfacing technique with the autonomic nervous system and demonstrate the possibility of regulating internal organ function, leading to new bioelectronic therapies and patient health monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Figure 1 Chronic autonomic nerve recording using CNT yarns. (a) CNT forest being pulled and spun to form CNT yarns that are 10 microns in diameter. (b) CNT yarns wound around the tip of a Tungsten microneedle used to implant the yarn into the nerve. (c) Two CNT yarns implanted in the rat vagus nerve separated by ~2 mm for differential recording of the neural activity [scale bar = 2 mm]. (d) Percutaneous plug with electrical connector that directly mates to the neural amplifier recording circuit board for signal amplification, filtering and acquisition. (e) Schematic of the complete recording assembly from the CNT yarn implants, lead wire connections, percutaneous plug, the external neural recording amplifier board and evaluation system board for data storage. (f) Post processed, spontaneous neural activity from the vagus nerve, 16-weeks post implant (blue). Trigger signal (green trace) indicating the hypoxia event administered to the anesthetized rat. Also shown are the markers for each identified neural spike and cluster grouping for activity identification and classification. Evaluation system board photo used with permission courtesy of Intan Technologies, LLC.](https://figures.cochat.ai/paper-figures/0210f535445841d6af84fb52b4b79e3e/chronic-interfacing-with-the-autonomic-nervous-system-using-carbon-nanotube-cnt-figure-1.jpg)







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Faradic electrodes based on oxides of iridium (IrOx) tend to have a higher charge capacity compared to titanium-derived electrodes due to their excellent electrochemical properties.[532,533]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [533]
Experimental — accuracy not yet measuredIn the citing paper
“In addition, neural signals from the glossopharyngeal and vagus nerves were chronically recorded using carbon nanotube (CNT) yarn electrodes [Fig.4(i)].109”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [109]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The American Journal of Physiology
(1899) · The American Naturalist · doi:10.1086/277182 · Cited by 5,654
A review of methods for spike sorting: the detection and classification of neural action potentials
Lewicki, M. S. (1998) · Network Computation in Neural Systems · doi:10.1088/0954-898x/9/4/001 · Cited by 1,370
Strong, Light, Multifunctional Fibers of Carbon Nanotubes with Ultrahigh Conductivity
Behabtu, N., Young, C. C., Tsentalovich, D. E., Kleinerman, O., Wang, X., Ma, A. W. K., Bengio, E. A., ter Waarbeek, R. F., de Jong, J. J., Hoogerwerf, R. E., et al. (2013) · Science · doi:10.1126/science.1228061 · Cited by 1,354
Functional and chemical anatomy of the afferent vagal system
Berthoud, H.-R., & Neuhuber, W. L. (2000) · Autonomic Neuroscience · doi:10.1016/s1566-0702(00)00215-0 · Cited by 1,280
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Carbon Nanotube Arrays with Strong Shear Binding-On and Easy Normal Lifting-Off
Qu, L., Dai, L., Stone, M., Xia, Z., & Wang, Z. L. (2008) · Science · doi:10.1126/science.1159503 · Cited by 745
Self-citationKozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Rush, A. J., George, M. S., Sackeim, H. A., Marangell, L. B., Husain, M. M., Giller, C., Nahas, Z., Haines, S., Simpson, R. K., & Goodman, R. (2000) · Biological Psychiatry · doi:10.1016/s0006-3223(99)00304-2 · Cited by 688
Groves, D. A., & Brown, V. J. (2005) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2005.01.004 · Cited by 675
Quantitative measures of cluster quality for use in extracellular recordings
Schmitzer-Torbert, N., Jackson, J., Henze, D., Harris, K., & Redish, A. D. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2004.09.066 · Cited by 662
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Zhang, X., Lu, W., Zhou, G., & Li, Q. (2020) · Advanced Materials · doi:10.1002/adma.201902028 · Cited by 408
Niu, Y., Liu, H., He, R., Li, Z., Ren, H., Gao, B., Guo, H., Genin, G. M., & Xu, F. (2020) · Materials Today · doi:10.1016/j.mattod.2020.10.004 · Cited by 224
Xue, Y., Chen, X., Wang, F., Lin, J., & Liu, J. (2023) · Advanced Materials · doi:10.1002/adma.202304095 · Cited by 183
Metadata
- Authors
- McCallum, G. A., Sui, X., Qiu, C., Marmerstein, J., Zheng, Y., Eggers, T. E., Hu, C., Dai, L., & Durand, D. M.
- Affiliations
- Case Western Reserve University (US)
- Shanghai Jiao Tong University (CN)
- Corresponding author
- Durand, Dominique M.
- ORCID
- Venue
- Scientific Reports
- Published
- 2017-09-15
- Volume
- 7
- Issue
- 1
- Pages
- 11723-11723
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC5601469
- OpenAlex
- W2755841351
- Semantic Scholar
- a4f3fc27204f81d22cde256d11e27c2f0ed369a5
- Cited by
- 102
- References
- 57
- Citations by year
- 2026: 6 · 2025: 13 · 2024: 10 · 2023: 11 · 2022: 9 · 2021: 21 · 2020: 14 · 2019: 11 · 2018: 6 · 2017: 1
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- UNSWorks (UNSW Sydney) (submittedVersion, cc-by-nc-nd)
- Funders
- GlaxoSmithKline
- Case Western Reserve University
- Scheme for Promotion of Academic and Research Collaboration
- National Institutes of Health (1s10od016164-01, 1u18eb021759-01)
- National Institute of Neurological Disorders and Stroke (R01NS032845)
- National Institute of Biomedical Imaging and Bioengineering (U18 EB021759)
- Office of Research Infrastructure Programs, National Institutes of Health (S10 OD016164)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- autonomic nervous system, glossopharyngeal nerve, vagus nerve, hypoxia detection, bioelectronic medicine, implantable neural interfaces
- MeSH terms
- Animals, Autonomic Nervous System, Biotechnology, Electric Stimulation, Electrodes, Implanted, Glossopharyngeal Nerve, Humans, Microelectrodes, Software, Vagus Nerve, Nanotubes, Carbon, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic interfacing with the autonomic nervous system using carbon nanotube (CNT) yarn electrodes. https://app.cochat.ai/papers/10.1038/s41598-017-10639-w
- The paper
- McCallum, G. A., Sui, X., Qiu, C., Marmerstein, J., Zheng, Y., Eggers, T. E., Hu, C., Dai, L., & Durand, D. M. (2017). Chronic interfacing with the autonomic nervous system using carbon nanotube (CNT) yarn electrodes. Scientific Reports. https://doi.org/10.1038/s41598-017-10639-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.