CoChat

Targeting to carcinoma cells with chitosan‐ and starch‐coated magnetic nanoparticles for magnetic hyperthermia

Open access
Kim, Dong‐Hyun, Kim, Kyoung‐Nam, Kim, Kwang‐Mahn, Lee, Yong‐Keun · 2009 · Journal of Biomedical Materials Research Part A
Cited by 124

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The delivery of hyperthermic thermoseeds to a specific target site with minimal side effects is an important challenge in targeted hyperthermia, which employs magnetic method and functional polymers. An external magnetic field is used to control the site‐specific targeting of the magnetic nanoparticles. Polymer‐coated magnetic nanoparticles can confer a higher affinity to the biological cell membranes. In this study, uncoated, chitosan‐coated, and starch‐coated magnetic nanoparticles were synthesized for use as a hyperthermic thermoseed. Each sample was examined with respect to their applications to hyperthermia using XRD, VSM, and FTIR. In addition, the temperature changes under an alternating magnetic field were observed. As in vitro tests, the magnetic responsiveness of chitosan‐ and starch‐coated magnetite was determined by a simple blood vessel model under various intensities of magnetic field. L929 normal cells and KB carcinoma cells were used to examine the cytotoxicity and affinity of each sample using the MTT method. The chitosan‐coated magnetic nanoparticles generated a higher Δ T of 23°C under an AC magnetic field than the starch‐coated magnetite, and the capturing rate of the particles was 96% under an external magnetic field of 0.4 T. The highest viability of L929 cells was 93.7%. Comparing the rate of KB cells capture with the rate of L929 cells capture, the rate of KB cells capture relatively increased with 10.8% in chitosan‐coated magnetic nanoparticles. Hence, chitosan‐coated magnetic nanoparticles are biocompatible and have a selective affinity to KB cells. The targeting of magnetic nanoparticles in hyperthermia was improved using a controlled magnetic field and a chitosan‐coating. Therefore, chitosan‐coated magnetic nanoparticles are expected to be promising materials for use in magnetic targeted hyperthermia. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.31775

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Kim, D., Kim, K., Kim, K., & Lee, Y.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2008-02-06
Volume
88A
Issue
1
Pages
1-11
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2020720736
Cited by
124
References
1
FWCI
6.40
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.