Peripheral nerve regeneration using composite poly(lactic acid‐caprolactone)/nerve growth factor conduits prepared by coaxial electrospinning
The DOI matches its Crossref record.
Abstract
Many neurotrophic factors have been shown to promote neurite outgrowth by improving the microenvironment that is required for nerve regeneration. However, the delivery of these bioactive agents to the nerve injury site, as well as effective and local release, remains a challenging problem. We have developed a novel composite nerve conduit comprised of poly(lactic acid‐caprolactone) (P(LLA‐CL)) and nerve growth factor (NGF). This was developed from core‐shell structured biodegradable nanofibers, which were fabricated by coaxial electrospinning of P(LLA‐CL) for the shell and bovine serum albumin (BSA) or BSA/NGF for the core. In rats, gaps of 10‐mm long sciatic nerves were bridged using an autograft, an empty P(LLA‐CL) conduit, a NGF injection P(LLA‐CL) conduit, a P(LLA‐CL)/NGF composite conduit, respectively. Regenerated nerve fibers were harvested and morphological and functional evaluation of nerve regeneration was performed at 12 weeks postsurgery. Although partial biodegradation and small cracks in the conduits were observed, the conduit outlines remained intact for 12 weeks after surgery. Based on functional and histological observations, the number and arrangement of regenerated nerve fibers, myelination, and nerve function reconstruction was similar in the P(LLA‐CL)/NGF conduit group to that of the nerve autograft group (p > 0.05), but was significantly greater to the empty P(LLA‐CL) and injection NGF P(LLA‐CL) conduit groups (both p < 0.05). Therefore, the composite P(LLA‐CL)/NGF conduit, which exhibited favorable mechanical properties and biocompatibility, could effectively promote sciatic nerve regeneration in rats. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Neural tissue engineering options for peripheral nerve regeneration
Gu, X., Ding, F., & Williams, D. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.064 · Cited by 630
“outcomes of peripheral nerve repair [184].”
Daly, W., Yao, L., Zeugolis, D., Windebank, A., & Pandit, A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0438 · Cited by 551
Electrospinning of polymer nanofibers for tissue regeneration
Jiang, T., Carbone, E. J., Lo, K. W.-H., & Laurencin, C. T. (2015) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.12.001 · Cited by 487
Designing electrospun nanofiber mats to promote wound healing – a review
Rieger, K. A., Birch, N. P., & Schiffman, J. D. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20795a · Cited by 479
Metadata
- Authors
- Liu, J., Wang, C., Wang, J., Ruan, H., & Fan, C.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2010-10-14
- Volume
- 96A
- Issue
- 1
- Pages
- 13-20
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2044588215
- Cited by
- 133
- References
- 0
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Peripheral nerve regeneration using composite poly(lactic acid‐caprolactone)/nerve growth factor conduits prepared by coaxial electrospinning. https://app.cochat.ai/papers/10.1002/jbm.a.32946
- The paper
- Liu, J., Wang, C., Wang, J., Ruan, H., & Fan, C. (2011). Peripheral nerve regeneration using composite poly(lactic acid‐caprolactone)/nerve growth factor conduits prepared by coaxial electrospinning. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.32946
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.