A human‐like collagen/chitosan electrospun nanofibrous scaffold from aqueous solution: Electrospun mechanism and biocompatibility
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Novel human‐like collagen (HLC)/chitosan blended with poly(ethylene oxide) (PEO) nanofibrous meshes of different ratios were fabricated by electrospinning from aqueous solutions. Through studying the effects of the three composition on the solution rheological properties and the morphology of electrospun meshes, the mechanism of electrospinning was explored at the molecular level, and the ratio of PEO/(HLC & chitosan) (w/w) should be controlled below 1/4 as a plasticizer and HLC/chitosan maintained 4/3 w/w. Obtained meshes were treated by 0.2% glutaraldehyde solution (95% ethanol) for crosslinking and 0.2 M glycine solution for blocking unreacted aldehyde groups and became insoluble with fiber diameters of 151 ± 33 to 278 ± 46 nm, PEO was leached out after crosslinking and rinsing. HLC/chitosan scaffolds (4/3, w/w) could mimic native ECM in both chemical component and structure and support cellular in‐growth in vivo while exhibited proper degradation rate in vivo. Bone marrow stromal cells adopted a flattened shape with filopodia‐ and lamellipodia‐like extensions in the scaffolds and grew as a confluent layer after 7 days of culture in vitro. This study indicated the feasibility of electrospun nanofabrious HLC/chitosan scaffold from aqueous solution for tissue engineering application. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part A:, 2011.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The application of recombinant human collagen in tissue engineering
Yang, C., Hillas, P. J., B??ez, J. A., Nokelainen, M., Balan, J., Tang, J., Spiro, R., & Polarek, J. W. (2004) · BioDrugs · doi:10.2165/00063030-200418020-00004 · Cited by 385
Cited by
Emerging chitin and chitosan nanofibrous materials for biomedical applications
Ding, F., Deng, H., Du, Y., Shi, X., & Wang, Q. (2014) · Nanoscale · doi:10.1039/c4nr02814g · Cited by 342
Applications of chitin and chitosan nanofibers in bone regenerative engineering
Tao, F., Cheng, Y., Shi, X., Zheng, H., Du, Y., Xiang, W., & Deng, H. (2020) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2019.115658 · Cited by 341
Advances in self-assembled chitosan nanomaterials for drug delivery
Yang, Y., Wang, S., Wang, Y., Wang, X., Wang, Q., & Chen, M. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.07.007 · Cited by 301
Krishnakumar, G. S., Sampath, S., Muthusamy, S., & John, M. A. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2018.11.081 · Cited by 114
Collagen and its modifications—crucial aspects with concern to its processing and analysis
Rýglová, Š., Braun, M., & Suchý, T. (2017) · Macromolecular Materials and Engineering · doi:10.1002/mame.201600460 · Cited by 106
Metadata
- Authors
- Chen, L., Zhu, C., Fan, D., Liu, B., Ma, X., Duan, Z., & Zhou, Y.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2011-08-23
- Volume
- 99A
- Issue
- 3
- Pages
- 395-409
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2005845270
- Cited by
- 49
- References
- 1
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.