Controlled drug delivery through a novel PEG hydrogel encapsulated silica aerogel system
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A novel composite material consisting of a silica aerogel core coated by a poly(ethylene) glycol (PEG) hydrogel was developed. The potential of this novel composite as a drug delivery system was tested with ketoprofen as a model drug due to its solubility in supercritical carbon dioxide. The results indicated that both drug loading capacity and drug release profiles could be tuned by changing hydrophobicity of aerogels, and that drug loading capacity increased with decreased hydrophobicity, while slower release rates were achieved with increased hydrophobicity. Furthermore, higher concentration of PEG diacrylate in the prepolymer solution of the hydrogel coating delayed the release of the drug which can be attributed to the lower permeability at higher PEG diacrylate concentrations. The novel composite developed in this study can be easily implemented to achieve the controlled delivery of various drugs and/or proteins for specific applications. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A:, 2012.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels in pharmaceutical formulations
Peppas, N. (2000) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(00)00090-4 · Cited by 4,011
Biodegradable polymeric nanoparticles as drug delivery devices
Soppimath, K. S., Aminabhavi, T. M., Kulkarni, A. R., & Rudzinski, W. E. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(00)00339-4 · Cited by 3,549 · cited 1×
“Recent advances in polymers and materials have improved design possibilities for nanostructured composites tremendously.(1,2) Porous silica aerogels are sol–gel derived nanostructured materials with high surface areas, high pore volumes, and low densities.”
Background
Cited by
Zhao, F., Yao, D., Guo, R., Deng, L., Dong, A., & Zhang, J. (2015) · Nanomaterials · doi:10.3390/nano5042054 · Cited by 400
Synthesis and biomedical applications of aerogels: Possibilities and challenges
Maleki, H., Durães, L., García-González, C. A., del Gaudio, P., Portugal, A., & Mahmoudi, M. (2016) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2016.05.011 · Cited by 386
An emerging platform for drug delivery: Aerogel based systems
Ulker, Z., & Erkey, C. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.12.033 · Cited by 346
Self-citationAerogels in drug delivery: From design to application
García-González, C. A., Sosnik, A., Kalmár, J., De Marco, I., Erkey, C., Concheiro, A., & Alvarez-Lorenzo, C. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.02.012 · Cited by 305
Self-citationReview of aerogel-based materials in biomedical applications
Stergar, J., & Maver, U. (2016) · Journal of Sol-Gel Science and Technology · doi:10.1007/s10971-016-3968-5 · Cited by 256
Metadata
- Authors
- Giray, S., Bal, T., Kartal, A. M., Kızılel, S., & Erkey*, C.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2012-02-28
- Volume
- 100A
- Issue
- 5
- Pages
- 1307-1315
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2060925585
- Cited by
- 85
- References
- 2
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.