CoChat

Incorporation of growth factor loaded microspheres into polymeric electrospun nanofibers for tissue engineering applications

Selcan Gungor‐Ozkerim, P., Balkan, Timucin, Kose, Gamze T., Sezai Sarac, A., Kok, Fatma N. · 2014 · Journal of Biomedical Materials Research Part A
Cited by 58

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Nanofibrous double‐layer matrices were prepared by electrospinning technique with the bottom layer formed from PCL (poly‐ε‐caprolactone)/PLLA (poly‐l‐lactic acid) nanofibers and the upper layer from PCL/Gelatin nanofibers. Bottom layer was designed to give mechanical strength to the system, whereas upper layer containing gelatin was optimized to improve the cell adhesion. Gelatin microspheres were incorporated in the middle of two layers for controlled growth factor delivery. Successful fabrication of the blend nanofibers were shown by spectroscopy. Scanning electron microscopy results demonstrated that bead‐free nanofibers with uniform morphology could be obtained by 10% w/v concentrations of PCL/PLLA and PCL/Gelatin solutions. Microspheres prepared by 15% gelatin concentration and cross‐linked with 7.5% glutaraldehyde solution were chosen after in vitro release studies for the incorporation to the double‐layer matrices. The optimized conditions were used to prepare fibroblast growth factor‐2 (FGF‐2) loaded microspheres. Preliminary cell culture studies showed that the FGF‐2 could be actively loaded into the microspheres and enhanced the cell attachment and proliferation. The complete system had a slow degradation rate in saline (18% weight loss in 2 months) and it could meanwhile preserve its integrity. This sandwich system prevented microsphere leakage from the scaffold, and the hydrophilic and bioactive nature of the fibers at the upper layer promoted cell attachment to the surface. PLLA/PCL layer, on the other hand, improved the mechanical properties of the system and enabled better handling. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 1897–1908, 2014.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.34857

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 58

Metadata

Authors
Selcan Gungor‐Ozkerim, P., Balkan, T., Kose, G. T., Sezai Sarac, A., & Kok, F. N.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2013-07-30
Volume
102
Issue
6
Pages
1897-1908
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W1537953328
Cited by
58
References
3
FWCI
1.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.