Effects of dopants on the biomechanical properties of conducting polymer films on platinum electrodes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Conducting polymers have often been described in literature as a coating for metal electrodes which will dampen the mechanical mismatch with neural tissue, encouraging intimate cell interactions. However, there is very limited quantitative analysis of conducting polymer mechanics and the relation to tissue interactions. This article systematically analyses the impact of coating platinum (Pt) electrodes with the conducting polymer poly(ethylene dioxythiophene) (PEDOT) doped with a series of common anions which have been explored for neural interfacing applications. Nanoindentation was used to determine the coating modulus and it was found that the polymer stiffness increased as the size of the dopant ion was increased, with PEDOT doped with polystyrene sulfonate (PSS) having the highest modulus at 3.2 GPa. This was more than double that of the ClO 4 doped PEDOT at 1.3 GPa. Similarly, the electrical properties of these materials were shown to have a size dependent behavior with the smaller anions producing PEDOT films with the highest charge transfer capacity and lowest impedance. Coating stiffness was found to have a negligible effect on in vitro neural cell survival and differentiation, but rather polymer surface morphology, dopant toxicity and mobility is found to have the greatest impact. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 2743–2754, 2014.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Abidian, M. R., Corey, J. M., Kipke, D. R., & Martin, D. C. (2010) · Small · doi:10.1002/smll.200901868 · Cited by 405
Cited by
Conjugated Polymers in Bioelectronics
Inal, S., Rivnay, J., Suiu, A.-O., Malliaras, G. G., & McCulloch, I. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00624 · Cited by 551
Conducting Polymers for Neural Prosthetic and Neural Interface Applications
Green, R., & Abidian, M. R. (2015) · Advanced Materials · doi:10.1002/adma.201501810 · Cited by 392
Self-citationOrganic electrode coatings for next-generation neural interfaces
Aregueta-Robles, U. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 254
Self-citationNeural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Yin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
Metadata
- Authors
- Baek, S., Green, R. A., & Poole‐Warren, L. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2013-09-25
- Volume
- 102
- Issue
- 8
- Pages
- 2743-2754
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1877702050
- Cited by
- 100
- References
- 3
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.