The DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.
Alkalization is responsible for antibacterial effects of corroding magnesium
Abstract
Magnesium alloys are presently investigated as potential medical implant materials for temporary applications. Magnesium has been reported to have antibacterial activities and could therefore be used to prevent antibiotic treatment-resistant bacterial implant infections. For characterizing the effects of magnesium on infectious bacteria, bioluminescent S. aureus or P. aeruginosa were employed. The proliferation of both types of bacteria was suppressed in the presence of metallic magnesium and also in aqueous magnesium corrosion extracts. Of the two soluble corrosion products, magnesium ions were well tolerated while antibacterial activities correlated with increased pH levels of the supernatants. The alkaline pH alone was sufficient for the antibacterial effects which were completely abolished when the pH of the corrosion supernatants was neutralized. These results demonstrate that pH increases are necessary and sufficient for the antibacterial activity of metallic magnesium. In an animal model magnesium implants showed an enhanced but variable resistance to bacterial colonization.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Uncoated Mg also reduced microbial adhesion significantly, likely owing to the release of corrosion products (Zn2+/H2/OH−) during rapid corrosion [[29], [30], [31]].”
From Nanocatalytic magnesium osteoimplants with biodegradable self-adaptive interfaces for therapeutic repair of infected bone defects (2026) · cites this paper as [30]
In the citing paper
“Crystal violet staining demonstrated significantly reduced biofilm biomass on TNE@AHAC versus Control and bare Mg (Fig. 3c and d), with the latter's partial suppression aligning with known antibacterial/antibiofilm effects derived from corroding Mg [29,30].”
From Nanocatalytic magnesium osteoimplants with biodegradable self-adaptive interfaces for therapeutic repair of infected bone defects (2026) · cites this paper as [30]
Citations
Cites
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer‐Lindenberg, A., Wirth, C. J., & Windhagen, H. J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,403
In vitro and in vivo corrosion measurements of magnesium alloys
Witte, F., Fischer, J., Nellesen, J., Crostack, H. ‐., Kaese, V., Pisch, A., Beckmann, F., & Windhagen, H. J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.037 · Cited by 1,389
The anodic dissolution of magnesium in chloride and sulphate solutions
Song, G., Atrens, A., John, D. S., Wu, X., & Nairn, J. (1997) · Corrosion Science · doi:10.1016/s0010-938x(97)00090-5 · Cited by 892
Makar, G. L., & Kruger, J. (1993) · International Materials Reviews · doi:10.1179/imr.1993.38.3.138 · Cited by 786
General and Localized Corrosion of Magnesium Alloys: A Critical Review
GHALI, E. L., Dietzel, W., & Kainer, K. U. (2004) · Journal of Materials Engineering and Performance · doi:10.1361/10599490417533 · Cited by 478
Biodegradable magnesium scaffolds: Part 1: Appropriate inflammatory response
Witte, F., Ulrich, H., Rudert, M., & Willbold, E. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31170 · Cited by 411
Robinson, D. A., Griffith, R. W., Shechtman, D., Evans, R. B., & Conzemius, M. G. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.10.007 · Cited by 351
Novel magnesium phosphate cements with high early strength and antibacterial properties
Mestres, G., & Ginebra, M. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.12.008 · Cited by 309
Titanium oral implants: surface characteristics, interface biology and clinical outcome
Palmquist, A., Omar, O., Esposito, M. A., Lausmaa, J., & Thomsen, P. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0118.focus · Cited by 259
In vivo evaluation of biodegradable magnesium alloy bone implant in the first 6 months implantation
Zhang, E., Xu, L., Yu, G., Pan, F. M., & Yang, K. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32132 · Cited by 257
Flagged first, then by citations
1 of the 43 references couldn’t be matched to a known paper.
Research works printed but not linked: 2
- 10.1128/AAC.03936-14 · DOI
- Sambrook J, 2001, Molecular Cloning: A Laboratory Manual
Cited by
Sorted by citations
Items 101–111 of 111
Widyasrini, D. A., Annisa, M., Sunarintyas, S., Samaranayake, L. P., & Siswomihardjo, W. (2025) · European Journal of Dentistry · doi:10.1055/s-0045-1806958 · Cited by 3
Degradation, cytotoxicity, and antibacterial properties of Fe-Mg powders in simulated body fluids
Estrada, R. G., Fagali, N., Multigner, M., Lozano, R. M., Pacha‐Olivenza, M. A., González-Martín, M. L., & Lieblich, M. (2025) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2025.115213
Biological bioadaptability of biodegradable metals
Zheng, Y. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-22133-0.00012-6
Lü, P., Huang, Y., Yang, J., Li, Y., Zhang, X., Wei, P., Wei, J., Yu, X., Zhao, B., & Xu, R. (2025) · Materials & Design · doi:10.1016/j.matdes.2025.115123
Preparation and Properties of Mg-based Metal Hydrogel Composites for Frostbite RewarmingPreprint
Yu, X., Hou, D., Wang, X., Xi, Y., Li, D., & Guo, J. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5984418
Surfactant-driven microtopographies on the surface of PLA-Mg films for antibacterial applications
Hierro‐Oliva, M., Escudero-Duch, C., Casares-López, J. M., Fernández-Grajera, M., Serrano-Yamba, R., Gallardo-Moreno, A. M., González-Martín, M. L., & Vilaboa, N. E. (2026) · Surfaces and Interfaces · doi:10.1016/j.surfin.2026.109306
Bulk Ag addition reduces biodegradation and enhances antibacterial properties of Mg-2Zn-0.2Ca alloy
Yi, F., Wu, M.-Z., Chen, Y., Yang, L., Guo, J., & Gao, Y. (2026) · npj Materials Degradation · doi:10.1038/s41529-026-00805-9
Agourrame, H., Amor, F., Ait-Ouakrim, E., Dahhou, M., Khachani, N., & Zarrouk, A. M. (2026) · RSC Advances · doi:10.1039/d6ra04417d
Zhang, M., Xue, X., Luo, T., Wang, Y., Bo, W., Wang, X., Xin, X., Wang, X., Yang, K., Wang, Y., et al. (2026) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6c00607
Optimized Ag enhances antibacterial activity and corrosion resistance of extruded Mg-2Zn-0.2Ca alloy
yi, F. R., Chen, Y., Guan, D., Yang, L., Li, J., & Gao, Y. (2026) · iScience · doi:10.1016/j.isci.2026.117220
Microbial Influence on Magnesium Alloy Corrosion: Mechanisms and Challenges in Biomedical Implants
Alansy, A. S., Xiaoting, S., Wang, Q., & Wang, W. (2026) · Biomedical Materials & Devices · doi:10.1007/s44174-026-00760-8
Metadata
- Authors
- Rahim, M. I., Eifler, R., Rais, B., & Mueller, P. P.
- Affiliations
- Helmholtz Centre for Infection Research (DE)
- Leibniz University Hannover (DE)
- Corresponding author
- Mueller, Peter P.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2015-05-24
- Volume
- 103
- Issue
- 11
- Pages
- 3526-3532
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2131108244
- Cited by
- 111
- References
- 43
- Citations by year
- 2026: 11 · 2025: 13 · 2024: 12 · 2023: 13 · 2022: 13 · 2021: 13 · 2020: 7 · 2019: 7 · 2018: 6 · 2017: 7 · 2016: 9
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research Part A (publishedVersion)
- PubMed (publishedVersion)
- Funders
- German Research Foundation (DFG) (SFB 599, projects D1, R8, and DR1)
- Joint stipend of the Higher Education Commission of Pakistan; German Academic Exchange Service (DAAD), Germany
- Topics
- Physical Sciences › Materials Science › Biomaterials › Magnesium Alloys: Properties and Applications
- Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
- Physical Sciences › Materials Science › Materials Chemistry › Titanium Alloys Microstructure and Properties
- Keywords
- magnesium corrosion, antibacterial activity, alkalization, pH, magnesium alloys, biomedical implants, implant-associated infection, Staphylococcus aureus, Pseudomonas aeruginosa, corrosion products, magnesium ions, bacterial colonization
- MeSH terms
- Alkalies, Animals, Anti-Bacterial Agents, Corrosion, Disease Models, Animal, Female, Hydrogen-Ion Concentration, Ions, Magnesium, Mice, Inbred BALB C, Microbial Sensitivity Tests, Pseudomonas aeruginosa, Solubility, Staphylococcus aureus, Prosthesis-Related Infections, Imaging, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review