The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fibrinogen adsorption to biomaterials
Open accessAbstract
Fibrinogen (Fg) adsorption is an important mechanism underlying cell adhesion to biomaterials and was the major focus of the author's research career. This article summarizes our work on Fg adsorption, with citations of related work as appropriate. The molecular properties of Fg that promote adsorption and cell adhesion will be described. In addition, the adsorption behavior of Fg from buffer, binary solutions with other proteins, and blood plasma will be discussed, including the Vroman effect. Studies of platelet adhesion to surfaces preadsorbed with blood plasmas selectively deficient in Fg, vitronectin (Vn), fibronectin (Fn), or von Willebrand's factor (vWf) will be reviewed. These studies clearly showed a major role for Fg in platelet adhesion under static conditions and both Fg and vWf for adhesion from flowing suspensions, but no significant role for Vn or Fn. However, it was also shown that platelet adhesion was poorly correlated with the total amount of adsorbed Fg, but very well correlated with the binding of antibodies specific to the cell binding domains of Fg. A brief overview of nonfouling surfaces for prevention of Fg adsorption will be given. A more extensive discussion of structural changes in Fg after its adsorption is included, including changes detected with both physicochemical and biological methods. A short discussion of the state of the art of structural determination of adsorbed proteins with computational methods is also given. A final section identifies Fg adsorption as the single most important event determining the biocompatibility of implants in soft tissue and in blood. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2777–2788, 2018.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zwitterionic hydrogels implanted in mice resist the foreign-body reaction
Zhang, L., Cao, Z., Bai, T., Carr, L., Ella-Menye, J.-R., Irvin, C., Ratner, B. D., & Jiang, S. (2013) · Nature Biotechnology · doi:10.1038/nbt.2580 · Cited by 1,035
Complement activation on poly(ethylene oxide)‐like radiofrequency glow discharge–deposited surfaces
Szott, L. M., Stein, M. J., Ratner, B. D., & Horbett, T. A. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32954 · Cited by 27
Self-citation
Cited by
The blood compatibility challenge. Part 2: Protein adsorption phenomena governing blood reactivity
Brash, J. L., Horbett, T. A., Latour, R. A., & Tengvall, P. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.022 · Cited by 282
Self-citationBioadhesion in the oral cavity and approaches for biofilm management by surface modifications
Sterzenbach, T., Helbig, R., Hannig, C., & Hannig, M. (2020) · Clinical Oral Investigations · doi:10.1007/s00784-020-03646-1 · Cited by 212
Metadata
- Authors
- Horbett, T. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2018-09-08
- Volume
- 106
- Issue
- 10
- Pages
- 2777-2788
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2808680438
- Cited by
- 187
- References
- 2
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fibrinogen adsorption to biomaterials. https://app.cochat.ai/papers/10.1002/jbm.a.36460
- The paper
- Horbett, T. A. (2018). Fibrinogen adsorption to biomaterials. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.36460
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.