Preparation of fibrin gel scaffolds containing MWCNT/PU nanofibers for neural tissue engineering
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Compared to the peripheral nervous system, in the central nervous system (CNS) disorders, neurons are less able to regenerate and reconstruct the neural tissue. Tissue engineering is considered as a promising approach for neural regeneration and restoring neurologic function after CNS injuries. Nanofibrous hydrogels have been recently used as three‐dimensional (3D) scaffolds for tissue engineering applications. In this kind of composites, hydrogels are incorporated with fibers to enhance their poor mechanical properties. Furthermore, introducing meshes within hydrogels can result in composites associated with advantages of both components. In the present study, we have prepared 3D nanofibrous hydrogel scaffolds based on fibrin/polyurethane/multiwall carbon nanotube (fibrin/PU/MWCNT), for application as composite scaffolds for neural tissue engineering. The fabricated fibrin/PU/MWCNT hydrogel scaffolds were characterized and their ability to support cell attachment and viability was assessed in comparison with fibrin hydrogel. Scanning electron microscopy (SEM) analysis was performed to examine the microstructural features of scaffolds. The rate of biodegradation and rheological properties of scaffolds were also investigated. After isolation of human endometrial stem cells (hEnSCs), they were cultured into the scaffolds, then their attachment and viability were assessed through SEM analysis, MTT assay and DAPI staining. Based on the results, the viability and proliferation of hEnSCs in the fibrin/PU/MWCNT hydrogels were higher than those in fibrin hydrogels. Therefore, our novel fabricated fibrin/PU/MWCNT hydrogel is able to support cell proliferation and can be used as a scaffold to provide an appropriate microenvironment for enhancing cell viability. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 802–814, 2019.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Prabhakaran, M. P., Venugopal, J. R., & Ramakrishna, S. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.05.057 · Cited by 311
Cited by
Krishani, M., Shin, W. Y., Suhaimi, H., & Sambudi, N. S. (2023) · Gels · doi:10.3390/gels9020100 · Cited by 328
Recent advances in tissue engineering scaffolds based on polyurethane and modified polyurethane
Naureen, B., Haseeb, A. S. M. A., Basirun, W. J., & Muhamad, F. (2021) · Materials Science and Engineering: C · doi:10.1016/j.msec.2020.111228 · Cited by 200
Rational design of biodegradable thermoplastic polyurethanes for tissue repair
Xu, C., & Hong, Y. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.11.029 · Cited by 109
Mirshekar, M., Afkhami, H., Razavi, S., Masjedian Jazi, F., Darban-Sarokhalil, D., Ohadi, E., Nezhad, M. M., & Karimi, R. (2023) · Burns · doi:10.1016/j.burns.2023.01.005 · Cited by 39
Metadata
- Authors
- Hasanzadeh, E., Ebrahimi‐Barough, S., Mirzaei, E., Azami, M., Tavangar, S. M., Mahmoodi, N., Basiri, A., & Ai, J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2019-01-11
- Volume
- 107
- Issue
- 4
- Pages
- 802-814
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2905778960
- Cited by
- 86
- References
- 2
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preparation of fibrin gel scaffolds containing MWCNT/PU nanofibers for neural tissue engineering. https://app.cochat.ai/papers/10.1002/jbm.a.36596
- The paper
- Hasanzadeh, E., Ebrahimi‐Barough, S., Mirzaei, E., Azami, M., Tavangar, S. M., Mahmoodi, N., Basiri, A., & Ai, J. (2019). Preparation of fibrin gel scaffolds containing MWCNT/PU nanofibers for neural tissue engineering. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.36596
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.