CoChat

Development of hydroxyapatite bone scaffold for controlled drug release via poly(ϵ‐caprolactone) and hydroxyapatite hybrid coatings

Kim, Hae‐Won, Knowles, Jonathan C., Kim, Hyoun‐Ee · 2004 · Journal of Biomedical Materials Research Part B: Applied Biomaterials
Cited by 124

The DOI matches its Crossref record.

Abstract

A scaffold‐coating design, the hydroxyapatite (HA) porous bone scaffold coated with poly(ϵ‐)caprolactone (PCL) and HA powder hybrids, was developed for use as tissue‐regeneration and controlled‐release system. An antibiotic drug, tetracycline hydrochloride (TCH), was encapsulated within the hybrid coating layer through a dip‐coating and solvent‐casting method. Coating cycle and drug loading amount differed to control the level of drug‐release rate. The HA scaffold framework, obtained by a polymeric foam reticulate method, exhibited a highly porous structure, with porosity and pore size of approximately 87% and 180 μm, respectively. The hybrid layer, consisting of PCL sheet and HA fine powders, was uniformly coated on the scaffold surface. The coating layer exhibited only PCL and HA phases and structures, revealing no chemical interaction among the coating components, as observed by X‐ray diffraction (XRD) and Fourier‐transform infrared (FTIR) analyses. The coated‐HA scaffolds showed an effective stress distribution behavior in response to an applied load, as confirmed by the compressive stress–strain curve. The mechanical properties of the coated scaffolds were improved highly with coatings; the compressive strength and elastic modulus of the cyclic coated scaffolds were ∼3–4 times, and the energy absorption were ∼8 times, higher than those without coating. These improvements were attributed mainly to the shielding of framework flaws by a flexible coating layer and partially to the thicker stems (porosity reduction). The dissolution of the coated scaffolds in a phosphate‐buffered saline (PBS) solution increased with incubation time. The drug was released sharply within the initial several hours (∼2 h), but the rate decreased further, showing a sustained release. The release amount was well controlled via coating‐cycle and initial drug loading amount, suggesting the effectiveness of the coating‐scaffold design as a drug‐delivery system. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 70B: 240–249, 2004

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.b.30038

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 124

Metadata

Authors
Kim, H., Knowles, J. C., & Kim, H.
Venue
Journal of Biomedical Materials Research Part B: Applied Biomaterials
Publisher
Wiley
Published
2004-04-27
Volume
70B
Issue
2
Pages
240-249
ISSN
  • 1552-4973 (ISSN-L)
  • 1552-4981
OpenAlex
W2141845204
Cited by
124
References
0
FWCI
5.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of hydroxyapatite bone scaffold for controlled drug release via poly(ϵ‐caprolactone) and hydroxyapatite hybrid coatings. https://app.cochat.ai/papers/10.1002/jbm.b.30038
The paper
Kim, H., Knowles, J. C., & Kim, H. (2004). Development of hydroxyapatite bone scaffold for controlled drug release via poly(ϵ‐caprolactone) and hydroxyapatite hybrid coatings. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.30038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.