Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 182

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Addressing thrombogenicity in vascular graft construction

Sarkar, Sandip, Sales, Kevin M., Hamilton, George, Seifalian, Alexander M.·2007·Journal of Biomedical Materials Research Part B: Applied Biomaterials

Abstract

Thrombosis is a major cause of poor patency in synthetic vascular grafts for small diameter vessel (<6 mm) bypass. Arteries have a host of structural mechanisms by which they prevent triggering of platelet activation and the clotting cascade. Many of these are present in vascular endothelial cells. These mechanisms act together with perpetual feedback at different levels, providing a constantly fine‐tuned non‐thrombogenic environment. The arterial wall anatomy also serves to promote thrombosis as a healing mechanism when it has been severely injured. Surface modification of synthetic graft surfaces to attenuate the coagulation cascade has reduced thrombosis levels and improved patency in vitro and in animal models. Success in this endeavor is critically dependent on the methods used to modify the surface. Platelets adhere to positively charged surfaces due to their own negative charge. They also preferentially attach to hydrophobic surfaces. Therefore synthetic graft development is concerned with hydrophilic materials with negative surface charge. However, fibrinogen has both hydrophilic and hydrophobic binding sites–amphiphilic materials reduce its adhesion and subsequent platelet activation. The self‐endothelializing synthetic graft is an attractive proposition as a confluent endothelial layer incorporates many of the anti‐thrombogenic properties of arteries. Surface modification to promote this has shown good results in animal models. The difficulties experienced in achieving spontaneous endothelialisation in humans have lead to the investigation of pre‐implantation in vitro endothelial cell seeding. These approaches ultimately aim to result in novel synthetic grafts which are anti‐thrombogenic and hence suitable for coronary and distal infrainguinal bypass. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.b.30710

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 182

Metadata

Authors
Sarkar, S., Sales, K. M., Hamilton, G., & Seifalian, A. M.
Venue
Journal of Biomedical Materials Research Part B: Applied Biomaterials
Publisher
Wiley
Published
2007-06-06
Volume
82B
Issue
1
Pages
100-108
ISSN
  • 1552-4973 (ISSN-L)
  • 1552-4981
OpenAlex
W2057151607
Cited by
182
References
2
FWCI
2.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.