Stability of poly(3,4‐ethylene dioxythiophene) materials intended for implants
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This study presents experiments designed to study the stability of the conducting polymer poly(3,4‐ethylene dioxythiophene) (PEDOT), under simulated physiological conditions using phosphate‐buffered saline (PBS) and hydrogen peroxide (H 2 O 2) (0.01 M) at 37°C over a 5‐ to 6‐week period. Voltage pulsing in PBS was used as an additional test environment. The influence of switching the counter ion used in electropolymerization from polystyrene sulphonate (PSS) to heparin was investigated. Absorbance spectroscopy and cyclic voltammetry were used to evaluate the material properties. Most of the samples in H 2 O 2 lost both electroactivity and optical absorbance within the study period, but PEDOT:PSS was found slightly more stable than PEDOT:heparin. Polymers were relatively stable in PBS throughout the study period, with around 80% of electroactivity remaining after 5 weeks, disregarding delamination, which was a significant problem especially for polymer on indium tin oxide substrates. Voltage pulsing in PBS did not increase degradation. The counter ion influenced the time course of degradation in oxidizing agents. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 2×
“All of these studies, apart from experiments by Ludwig et al.,14 have a study period of less than 15 days.”
Background
Cited by
Soft and elastic hydrogel-based microelectronics for localized low-voltage neuromodulation
Liu, Y., Liu, J., Chen, S., Lei, T., Kim, Y., Niu, S., Wang, H., Wang, X., Foudeh, A. M., Tok, J. B.-H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0335-6 · Cited by 811
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Organic Bioelectronics: Bridging the Signaling Gap between Biology and Technology
Simon, D. T., Gabrielsson, E. O., Tybrandt, K., & Berggren, M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00146 · Cited by 568
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
“Similar substrate dependent mechanical delamination of PEDOT has been reported in other studies [20], [31].”
BackgroundResultBoehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 308
Self-citation
Metadata
- Authors
- Thaning, E. M., Asplund, M. L. M., Nyberg, T. A., Inganäs, O. W., & von Holst, H.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2010-04-02
- Volume
- 93B
- Issue
- 2
- Pages
- 407-415
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2088561873
- Cited by
- 92
- References
- 3
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stability of poly(3,4‐ethylene dioxythiophene) materials intended for implants. https://app.cochat.ai/papers/10.1002/jbm.b.31597
- The paper
- Thaning, E. M., Asplund, M. L. M., Nyberg, T. A., Inganäs, O. W., & von Holst, H. (2010). Stability of poly(3,4‐ethylene dioxythiophene) materials intended for implants. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.31597
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.