Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording

Venkatraman, Subramaniam, Hendricks, Jeffrey, King, Zachary A., Sereno, Andrew J., Richardson-Burns, Sarah, Martin, David, Carmena, Jose M. · 2011 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Cortical neural prostheses require chronically implanted small-area microelectrode arrays that simultaneously record and stimulate neural activity. It is necessary to develop new materials with low interface impedance and large charge transfer capacity for this application and we explore the use of conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) for the same. We subjected PEDOT coated electrodes to voltage cycling between -0.6 and 0.8 V, 24 h continuous biphasic stimulation at 3 mC/cm² and accelerated aging for four weeks. Characterization was performed using cyclic voltammetry, electrochemical impedance spectroscopy, and voltage transient measurements. We found that PEDOT coated electrodes showed a charge injection limit 15 times higher than Platinum Iridium (PtIr) electrodes and electroplated Iridium Oxide (IrOx) electrodes when using constant current stimulation at zero voltage bias. In vivo chronic testing of microelectrode arrays implanted in rat cortex revealed that PEDOT coated electrodes show higher signal-to-noise recordings and superior charge injection compared to PtIr electrodes.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2011.2109399

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Research works printed but not linked: 2

  1. 0, Standard Practice for Accelerated Aging of Ultra-High Molecular Weight Polyethylene after Gamma Irradiation in Air
  2. 0, Standard Guide for Accelerated Aging of Sterile Barrier Systems for Medical Devices

Cited by

See all 342

Metadata

Authors
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M.
Affiliations
  • Qualcomm (United States) (US)
  • University of Michigan (US)
  • University of Delaware (US)
  • University of California, Berkeley (US)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2011-06
Volume
19
Issue
3
Pages
307-316
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2154453638
Cited by
319
References
39
Citations by year
2026: 16 · 2025: 22 · 2024: 14 · 2023: 30 · 2022: 28 · 2021: 24 · 2020: 35 · 2019: 24 · 2018: 24 · 2017: 27 · 2016: 16 · 2015: 20 · 2014: 12 · 2013: 14 · 2012: 11
FWCI
5.16
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
Keywords
PEDOT, conducting polymers, neural microelectrodes, neurostimulation, neural recording, neural prostheses, charge injection limit, electrode impedance, chronic implantation, cortical implants, platinum-iridium electrodes, iridium oxide electrodes, signal-to-noise ratio, voltage cycling, accelerated aging
MeSH terms
Animals, Electric Stimulation, Electrodes, Electrodes, Implanted, Electronics, Female, Iridium, Microelectrodes, Neurons, Polymers, Prosthesis Design, Rats, Sprague-Dawley, Bridged Bicyclo Compounds, Heterocyclic, Rats, Neural Prostheses

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording. https://app.cochat.ai/papers/10.1109/tnsre.2011.2109399
The paper
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011). In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2011.2109399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.