The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Calcium phosphate‐based composites as injectable bone substitute materials
Abstract
A major weakness of current orthopedic implant materials, for instance sintered hydroxyapatite (HA), is that they exist as a hardened form, requiring the surgeon to fit the surgical site around an implant to the desired shape. This can cause an increase in bone loss, trauma to the surrounding tissue, and longer surgical time. A convenient alternative to harden bone filling materials are injectable bone substitutes (IBS). In this article, recent progress in the development and application of calcium phosphate (CP)‐based composites use as IBS is reviewed. CP materials have been used widely for bone replacement because of their similarity to the mineral component of bone. The main limitation of bulk CP materials is their brittle nature and poor mechanical properties. There is significant effort to reinforce or improve the mechanical properties and injectability of calcium phosphate cement (CPC) and this review resumes different alternatives presented in this specialized literature. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Cited by
Fernandez de Grado, G., Keller, L., Idoux-Gillet, Y., Wagner, Q., Musset, A.-M., Benkirane-Jessel, N., Bornert, F., & Offner, D. (2018) · Journal of Tissue Engineering · doi:10.1177/2041731418776819 · Cited by 912
How smart do biomaterials need to be? A translational science and clinical point of view
Holzapfel, B. M., Reichert, J. C., Schantz, J.-T., Gbureck, U., Rackwitz, L., Nöth, U., Jakob, F., Rudert, M., Groll, J., & Hutmacher, D. W. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.009 · Cited by 552
Hannink, G., & Arts, J. J. C. (2011) · Injury · doi:10.1016/j.injury.2011.06.008 · Cited by 444
Zhou, H., Liang, B., Jiang, H., Deng, Z., & Yu, K. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.03.004 · Cited by 377
Chai, Y. C., Carlier, A., Bolander, J., Roberts, S. J., Geris, L., Schrooten, J., Van Oosterwyck, H., & Luyten, F. P. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.07.002 · Cited by 305
Metadata
- Authors
- Low, K. L., Tan, S. H., Zein, S. H. S., Roether, J. A., Mouriño, V., & Boccaccini, A. R.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2010-03-24
- Volume
- 94B
- Issue
- 1
- Pages
- 273-286
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W1555194482
- Cited by
- 212
- References
- 1
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calcium phosphate‐based composites as injectable bone substitute materials. https://app.cochat.ai/papers/10.1002/jbm.b.31619
- The paper
- Low, K. L., Tan, S. H., Zein, S. H. S., Roether, J. A., Mouriño, V., & Boccaccini, A. R. (2010). Calcium phosphate‐based composites as injectable bone substitute materials. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.31619
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.