Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 272

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Highly porous titanium scaffolds for orthopaedic applications

Dabrowski, Bogdan, Swieszkowski, Wojciech, Godlinski, Dirk, Kurzydlowski, Krzysztof J.·2010·Journal of Biomedical Materials Research Part B: Applied Biomaterials

Abstract

For many years, the solid metals and their alloys have been widely used for fabrication of the implants replacing hard human tissues or their functions. To improve fixation of solid implants to the surrounding bone tissues, the materials with porous structures have been introduced. By tissue ingrowing into a porous structure of metallic implant, the bonding between the implant and the bone has been obtained. Substantial pore interconnectivity, in metallic implants, allows extensive body fluid transport through the porous implant. This can provoke bone tissue ingrowth, consequently, leading to the development of highly porous metallic implants, which could be used as scaffolds in bone tissue engineering. The goal of this study was to develop and then investigate properties of highly porous titanium structures received from powder metallurgy process. The properties of porous titanium samples, such as microstructure, porosity, Young's modulus, strength, together with permeability and corrosion resistance were investigated. Porous titanium scaffolds with nonhomogeneous distribution of interconnected pores with pore size in the range up to 600 μm in diameter and a total porosity in the range up to 75% were developed. The relatively high permeability was observed for samples with highest values of porosity. Comparing to cast titanium, the porous titanium was low resistant to corrosion. The mechanical parameters of the investigated samples were similar to those for cancellous bone. The development of high‐porous titanium material shows high potential to be modern material for creating a 3D structure for bone regeneration and implant fixation. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.b.31682

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 272

Metadata

Authors
Dabrowski, B., Swieszkowski, W., Godlinski, D., & Kurzydlowski, K. J.
Venue
Journal of Biomedical Materials Research Part B: Applied Biomaterials
Publisher
Wiley
Published
2010-08-05
Volume
95B
Issue
1
Pages
53-61
ISSN
  • 1552-4973 (ISSN-L)
  • 1552-4981
OpenAlex
W1985147143
Cited by
272
References
19
FWCI
5.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly porous titanium scaffolds for orthopaedic applications. https://app.cochat.ai/papers/10.1002/jbm.b.31682
The paper
Dabrowski, B., Swieszkowski, W., Godlinski, D., & Kurzydlowski, K. J. (2010). Highly porous titanium scaffolds for orthopaedic applications. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.31682

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).