Evaluation of magnesium ions release, biocorrosion, and hemocompatibility of MAO/PLLA‐modified magnesium alloy WE42
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Magnesium alloys may potentially be applied as biodegradable metallic materials in cardiovascular stent. However, the high corrosion rate hinders its clinical application. In this study, a new approach was adopted to control the corrosion rate by fabricating a biocompatible micro‐arc oxidation/poly‐L‐lactic acid (MAO/PLLA) composite coating on the magnesium alloy WE42 substrate and the biocompatibility of the modified samples was investigated. The scanning electronic microscope (SEM) images were used to demonstrate the morphology of the samples before and after being submerged in hanks solution for 4 weeks. The degradation was evaluated through the magnesium ions release rate and electrochemical impedance spectroscopy (EIS) test. The biocompatibility of the samples was demonstrated by coagulation time and hemolysis behavior. The result shows that the poly‐L‐lactic acid (PLLA) effectively improved the corrosion resistance by sealing the microcracks and microholes on the surface of the MAO coating. The modified samples had good compatibility. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Road to Bioabsorbable Stents: Reaching Clinical Reality?
Erne, P., Schier, M., & Resink, T. J. (2006) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-004-0341-9 · Cited by 249
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Sankara Narayanan, T. S. N., Park, I. S., & Lee, M. H. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.08.002 · Cited by 639
Plasma electrolytic oxidation of magnesium and its alloys: Mechanism, properties and applications
Barati Darband, G., Aliofkhazraei, M., Hamghalam, P., & Valizade, N. (2017) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2017.02.004 · Cited by 594
Li, X., Liu, X., Wu, S., Yeung, K. W. K., Zheng, Y., & Chu, P. K. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.09.005 · Cited by 428
Magnesium biomaterials for orthopedic application: A review from a biological perspective
Walker, J., Shadanbaz, S., Woodfield, T. B. F., Staiger, M. P., & Dias, G. J. (2014) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33113 · Cited by 352
Metadata
- Authors
- Lu, P., Cao, L., Liu, Y., Xu, X., & Wu, X.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2010-11-04
- Volume
- 96B
- Issue
- 1
- Pages
- 101-109
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2117216274
- Cited by
- 108
- References
- 1
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.