The DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Plasma electrolytic oxidation of magnesium and its alloys: Mechanism, properties and applications
Open accessAbstract
Plasma Electrolyte Oxidation (PEO) process has increasingly been employed to improve magnesium surface properties by fabrication of an MgO-based coating. Originating from conventional anodizing procedures, this high-voltage process produces an adhesive ceramic film on the surface. The present article provides a comprehensive review around mechanisms of PEO coatings fabrication and their different properties. Due to complexity of PEO coatings formation, a complete explanation regarding fabrication mechanisms of PEO coatings has not yet been proposed; however, the most important advancements in the field of fabrication mechanisms of PEO coatings were gathered in this work. Mechanisms of PEO coatings fabrication on magnesium were reviewed considering voltage–time plots, optical spectrometry, acoustic emission spectrometry and electronic properties of the ceramic film. Afterwards, the coatings properties, affecting parameters and improvement strategies were discussed. In addition, corrosion resistance of coatings, important factors in corrosion resistance and methods for corrosion resistance improvement were considered. Tribological properties (important factors and improvement methods) of coatings were also studied. Since magnesium and its alloys are broadly used in biological applications, the biological properties of PEO coatings, important factors in their biological performance and existing methods for improvement of coatings were explained. Addition of ceramic based nanoparticles and formation of nanocomposite coatings may considerably influence properties of plasma electrolyte oxidation coatings. Nanocomposite coatings properties and nanoparticles adsorption mechanisms were included in a separate sector. Another method to improve coatings properties is formation of hybrid coatings on PEO coatings which was discussed in the end.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bioceramics: From Concept to Clinic
Hench, L. L. (1991) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1991.tb07132.x · Cited by 4,977
Antimicrobial effects of silver nanoparticles
Kim, J. S., Kuk, E., Yu, K. N., Kim, J.-H., Park, S. J., Lee, H. J., Kim, S. H., Park, Y. K., Park, Y. H., Hwang, C.-Y., et al. (2007) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2006.12.001 · Cited by 4,918
Protective coatings on magnesium and its alloys — a critical review
Gray, J. E., & Luan, B. (2002) · Journal of Alloys and Compounds · doi:10.1016/s0925-8388(01)01899-0 · Cited by 2,525
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395
Corrosion Mechanisms of Magnesium Alloys
Song, G. L., & Atrens, A. (1999) · Advanced Engineering Materials · doi:10.1002/(sici)1527-2648(199909)1:1<11::aid-adem11>3.0.co;2-n · Cited by 2,365
The history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,860
Electrochemistry at Semiconductor and Oxidized Metal Electrodes
Morrison, S. R. (1980) · Springer eBooks · doi:10.1007/978-1-4613-3144-5 · Cited by 1,665
Development of new metallic alloys for biomedical applications
Niinomi, M., Nakai, M., & Hieda, J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.037 · Cited by 1,623
The development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593
Control of biodegradation of biocompatable magnesium alloys
Song, G. (2007) · Corrosion Science · doi:10.1016/j.corsci.2007.01.001 · Cited by 1,514
Cited by
Barati Darband, G., Aliofkhazraei, M., Khorsand, S., Sokhanvar, S., & Kaboli, A. (2020) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2018.01.013 · Cited by 482
Self-citationRakoch, A. G., Monakhova, E. P., Khabibullina, Z. V., Serdechnova, M., Blawert, C., Zheludkevich, M. L., & Gladkova, A. A. (2020) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2020.06.002 · Cited by 134
Zhang, D., Cheng, S., Tan, J., Xie, J., Zhang, Y., Chen, S., Du, H., Qian, S., Qiao, Y., Peng, F., et al. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.01.032 · Cited by 79
Metadata
- Authors
- Barati Darband, G., Aliofkhazraei, M., Hamghalam, P., & Valizade, N.
- Venue
- Journal of Magnesium and Alloys
- Publisher
- Elsevier BV
- Published
- 2017-03
- Volume
- 5
- Issue
- 1
- Pages
- 74-132
- ISSN
- 2213-9567 (ISSN-L)
- OpenAlex
- W2601764143
- Cited by
- 594
- References
- 103
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plasma electrolytic oxidation of magnesium and its alloys: Mechanism, properties and applications. https://app.cochat.ai/papers/10.1016/j.jma.2017.02.004
- The paper
- Barati Darband, G., Aliofkhazraei, M., Hamghalam, P., & Valizade, N. (2017). Plasma electrolytic oxidation of magnesium and its alloys: Mechanism, properties and applications. Journal of Magnesium and Alloys. https://doi.org/10.1016/j.jma.2017.02.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.