Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 268

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Stress shielding and fatigue limits of poly‐ether‐ether‐ketone dental implants

Lee, Woo‐Taek, Koak, Jai‐Young, Lim, Young‐Jun, Kim, Seong‐Kyun, Kwon, Ho‐Beom, Kim, Myung‐Joo·2012·Journal of Biomedical Materials Research Part B: Applied Biomaterials

Abstract

The poly‐ether‐ether‐ketone (PEEK) polymer is of great interest as an alternative to titanium in orthopedics because of its biocompatibility and low elastic modulus. This study evaluated the fatigue limits of PEEK and the effects of the low elastic modulus PEEK in relation to existing dental implants. Compressive loading tests were performed with glass fiber‐reinforced PEEK (GFR‐PEEK), carbon fiber‐reinforced PEEK (CFR‐PEEK), and titanium rods. Among these tests, GFR‐PEEK fatigue tests were performed according to ISO 14801. For the finite element analysis, three‐dimensional models of dental implants and bone were constructed. The implants in the test groups were coated with a 0.5‐mm thick and 5‐mm long PEEK layer on the upper intrabony area. The strain energy densities (SED) were calculated, and the bone resorption was predicted. The fatigue limits of GFR‐PEEK were 310 N and were higher than the static compressive strength of GFR‐PEEK. The bone around PEEK‐coated implants showed higher levels of SED than the bone in direct contact with the implants, and the wider diameter and stiffer implants showed lower levels of SED. The compressive strength of the GFR‐PEEK and CFR‐PEEK implants ranged within the bite force of the anterior and posterior dentitions, respectively, and the PEEK implants showed adequate fatigue limits for replacing the anterior teeth. Dental implants with PEEK coatings and PEEK implants may reduce stress shielding effects. Dental implant application of PEEK polymer—fatigue limit and stress shielding. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2012

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.b.32669

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 268

Metadata

Authors
Lee, W., Koak, J., Lim, Y., Kim, S., Kwon, H., & Kim, M.
Venue
Journal of Biomedical Materials Research Part B: Applied Biomaterials
Publisher
Wiley
Published
2012-02-14
Volume
100B
Issue
4
Pages
1044-1052
ISSN
  • 1552-4973 (ISSN-L)
  • 1552-4981
OpenAlex
W2025765018
Cited by
268
References
21
FWCI
4.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stress shielding and fatigue limits of poly‐ether‐ether‐ketone dental implants. https://app.cochat.ai/papers/10.1002/jbm.b.32669
The paper
Lee, W., Koak, J., Lim, Y., Kim, S., Kwon, H., & Kim, M. (2012). Stress shielding and fatigue limits of poly‐ether‐ether‐ketone dental implants. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.32669

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.