The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
PEEK biomaterials in trauma, orthopedic, and spinal implants
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Encyclopedia of polymer science and engineering
Mark, H., & Kroschwitz, J. I. (1985) · Wiley eBooks · Cited by 5,898
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642
HUISKES, R., WEINANS, H., & RIETBERGEN, B. V. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199201000-00014 · Cited by 1,213
The morphology of poly(aryl-ether-ether-ketone)
Blundell, D. J., & Osborn, B. N. (1983) · Polymer · doi:10.1016/0032-3861(83)90144-1 · Cited by 1,064
Kurtz, S. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00053-8 · Cited by 847
Self-citationCrystallization behaviour of poly(ether-ether-ketone)
Cebe, P., & Hong, S.-D. (1986) · Polymer · doi:10.1016/0032-3861(86)90006-6 · Cited by 714
The measurement of the crystallinity of polymers by DSC
Kong, Y., & Hay, J. N. (2002) · Polymer · doi:10.1016/s0032-3861(02)00235-5 · Cited by 634
Tan, K. H., Chua, C. K., Leong, K. F., Cheah, C. M., Cheang, P., Abu Bakar, M. S., & Cha, S. W. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00131-5 · Cited by 625
Internal plate fixation of fractures: short history and recent developments
Uhthoff, H. K., Poitras, P., & Backman, D. S. (2006) · Journal of Orthopaedic Science · doi:10.1007/s00776-005-0984-7 · Cited by 438
Cheng, S. Z. D., Cao, M. Y., & Wunderlich, B. (1986) · Macromolecules · doi:10.1021/ma00161a015 · Cited by 434
Cited by
Polyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prostheses
Alqurashi, H., Khurshid, Z., Syed, A. U. Y., Rashid Habib, S., Rokaya, D., & Zafar, M. S. (2021) · Journal of Advanced Research · doi:10.1016/j.jare.2020.09.004 · Cited by 300
Performance of biocompatible PEEK processed by fused deposition additive manufacturing
Arif, M. F., Kumar, S., Varadarajan, K. M., & Cantwell, W. J. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.03.015 · Cited by 296
Fused filament fabrication of peek: A review of process-structure-property relationships
Zanjanijam, A. R., Major, I., Lyons, J. G., Lafont, U., & Devine, D. M. (2020) · Polymers · doi:10.3390/polym12081665 · Cited by 240
Yuan, B., Cheng, Q., Zhao, R., Zhu, X., Yang, X., Yang, X., Zhang, K., Song, Y., & Zhang, X. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.014 · Cited by 204
A lung/liver-on-a-chip platform for acute and chronic toxicity studies
Bovard, D., Sandoz, A., Luettich, K., Frentzel, S., Iskandar, A., Marescotti, D., Trivedi, K., Guedj, E., Dutertre, Q., Peitsch, M. C., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc01029c · Cited by 195
Metadata
- Authors
- Kurtz, S. M., & Devine, J. N.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2007-11
- Volume
- 28
- Issue
- 32
- Pages
- 4845-4869
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2084594392
- Cited by
- 2,388
- References
- 61
- FWCI
- 16.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: PEEK biomaterials in trauma, orthopedic, and spinal implants. https://app.cochat.ai/papers/10.1016/j.biomaterials.2007.07.013
- The paper
- Kurtz, S. M., & Devine, J. N. (2007). PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials. https://doi.org/10.1016/j.biomaterials.2007.07.013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.