Formulation and evaluation of in situ forming PLA implant containing tinidazole for the treatment of periodontitis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Periodontitis is caused by periodontopathic bacteria and antibacterial agents are placed in a periodontal pocket with the intention of enhancing the local effect. To maximize the therapeutic effects while reducing the adverse effects, tinidazole was delivered by in situ forming system. One approach for reducing burst release rate was to testify in situ forming effect. The effect of 0%–10% (w/w) polyethylene glycol 400 and 3% (w/w) glycerol on the tinidazole release from a poly(DL‐lactide) (PLA) injectable implant was evaluated. The results showed that the in vitro initial burst release rate was decreased in the presence of poly(ethyleneglycol) PEG 400 and glycerol. A formulation containing 30% (w/w) PLA (Mw 7300) dissolved in 62% (w/w) N‐methyl‐2‐pyrrolidone, 5% (w/w) PEG 400, and 3%(w/w) glycerol with 5% (w/w) tinidazole was shown to be optimum. Twelve adult beagle dogs were used in the periodontitis model. The treatment group I, II, and positive control group was administrated with gel containing 5%(w/w) tinidazole, 2.5%(w/w) tinidazole, and periocline, respectively. Dog studies revealed that periocline and the developed formulation could significantly decrease symptoms of periodontitis, and they were better than gel containing 2.5% (w/w) tinidazole. The developed formulation could sustain the release of tinidazole for local delivery over 7 days. These findings suggested that the developed formulation was a viable alternative to conventional drug to cure periodontitis. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2012.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Research progress in toughening modification of poly(lactic acid)
Liu, H., & Zhang, J. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22283 · Cited by 767
Cited by
Parent, M., Nouvel, C., Koerber, M., Sapin, A., Maincent, P., & Boudier, A. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.08.024 · Cited by 263
Smart stimuli-responsive hydrogels for drug delivery in periodontitis treatment
Wang, Y., Li, J., Tang, M., Peng, C., Wang, G., Wang, J., Wang, X., Chang, X., Guo, J., & Gui, S. (2023) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2023.114688 · Cited by 100
Advances in Local Drug Delivery for Periodontal Treatment: Present Strategies and Future Directions
Nakajima, M., Yanagawa, M., Takikawa, H., Thien, T. T., Zegarra-Caceres, L., Yan, C., & Tabeta, K. (2025) · Biomolecules · doi:10.3390/biom15060903 · Cited by 40
“A burst drug release remains a major concern, even in smart systems [29].”
Wang, N., Huang, Z., Wang, S., Lang, M., & Zhang, X. (2021) · Journal of Bioactive and Compatible Polymers · doi:10.1177/0883911521992795 · Cited by 3
Metadata
- Authors
- Qin, Y., Yuan, M., Li, L., Li, W., & Xue, J.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2012-08-09
- Volume
- 100B
- Issue
- 8
- Pages
- 2197-2202
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2091787859
- Cited by
- 35
- References
- 1
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Formulation and evaluation of in situ forming PLA implant containing tinidazole for the treatment of periodontitis. https://app.cochat.ai/papers/10.1002/jbm.b.32788
- The paper
- Qin, Y., Yuan, M., Li, L., Li, W., & Xue, J. (2012). Formulation and evaluation of in situ forming PLA implant containing tinidazole for the treatment of periodontitis. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.32788
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.