Cited by 15

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Effects of iron oxide nanoparticles on biological responses and MR imaging properties in human mammary healthy and breast cancer epithelial cells

Zhang, Qin, Rajan, Sunder S., Tyner, Katherine M., Casey, Brendan J., Dugard, Christopher K., Jones, Yvonne, Paredes, Angel M., Clingman, Chekesha S., Howard, Paul C., Goering, Peter L.·2016·Journal of Biomedical Materials Research Part B: Applied Biomaterials

Abstract

Superparamagnetic iron oxide nanoparticles (SPIONs, diameters >50 nm) have received great attention due to their promising use as magnetic resonance imaging (MRI) contrast agents. In this study, we evaluated the cellular uptake and biological responses in vitro of ultrasmall SPIONs (USPIONs, diameters < 50 nm). We compared the cellular responses between breast epithelia isolated from healthy and breast cancer donors after exposure to carboxy‐terminated USPIONs (10 and 30 nm PEG‐coated, 10 and 30 nm non‐PEG‐coated). The particles were characterized using transmission electron microscopy (TEM), dynamic light scattering (DLS) and gel electrophoresis. Cellular interactions with USPIONs were assessed by confocal microscopy and TEM. Cellular uptake of USPIONs was quantified using ICP‐MS. Cell viability was measured by MTT and neutral red uptake assays. T2* weighted MRI scans were performed using a 7T scanner. Results demonstrated that cell association/internalization of USPIONs was size‐ and surface coating‐dependent (PEG vs. non‐PEG), and higher cellular uptake of 10 and 30 nm non‐coated particles was observed in both cell types compared with PEG‐coated particles. Cell uptake for 10 and 30 nm non‐coated particles was higher in cancer cells from two of three tested donors compared to healthy cells from three donors. There was no significant cytotoxicity observed for all tested particles. Significantly enhanced MRI contrast was observed following exposure to 10 and 30 nm non‐coated particles compared to PEG‐coated particles in both cell types. In comparison, cancer cells showed more enhanced MRI signals when compared to normal cells. The data indicate that cell responses following exposure to USPIONs are dependent on particle properties. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1032–1042, 2016.

Overview

Integrity signals

Registry

Crossref · 10.1002/jbm.b.33450

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 2 references

Research works printed but not linked: 37

  1. 10.1158/0008-5472.CAN-10-3021 · DOI
  2. 10.1016/j.addr.2006.09.013 · DOI
  3. 10.1021/nn800034w · DOI
  4. 10.1002/nbm.924 · DOI · Paper page
  5. 10.1016/j.nano.2011.08.017 · DOI
  6. 10.1007/s10439-005-9002-7 · DOI
  7. 10.1007/s00330-004-2405-2 · DOI
  8. 10.1148/radiol.2432060120 · DOI
  9. 10.1002/wnan.36 · DOI
  10. 10.3109/09687688.2010.481640 · DOI
  11. 10.1158/1078-0432.CCR-10-3420 · DOI
  12. 10.2217/17435889.2.1.23 · DOI · Paper page
  13. 10.1021/ar2000277 · DOI
  14. Dvorak HF, 1988, Identification and characterization of the blood vessels of solid tumors that are leaky to circulating macromolecules, Am J Pathol, 133, 95
  15. Sevick EM, 1991, Measurement of capillary filtration coefficient in a solid tumor, Cancer Res, 51, 1352
  16. Gerlowski LE, 1985, Effect of hyperthermia on microvascular permeability to macromolecules in normal and tumor tissues, Int J Microcirc Clin Exp, 4, 363
  17. 10.1016/0026-2862(86)90018-X · DOI
  18. 10.1016/S1040-8428(86)80023-3 · DOI
  19. 10.1186/1477-3155-10-10 · DOI
  20. Yuan F, 1994, Microvascular permeability and interstitial penetration of sterically stabilized (stealth) liposomes in a human tumor xenograft, Cancer Res, 54, 3352
  21. 10.1002/jbm.a.30781 · DOI
  22. 10.2217/17435889.4.2.145 · DOI
  23. 10.1016/j.biomaterials.2008.05.015 · DOI
  24. 10.1016/j.biomaterials.2004.05.022 · DOI
  25. 10.1007/s12013-012-9367-9 · DOI
  26. Thorek DL, 2011, Superparamagnetic iron oxide‐enhanced magnetic resonance imaging of neuroinflammation in a rat model of radicular pain, Mol Imaging, 10, 206, 10.2310/7290.2010.00042 · DOI
  27. 10.1109/TNB.2003.820277 · DOI
  28. 10.1023/B:JMSM.0000021126.32934.20 · DOI
  29. 10.1166/jnn.2010.2488 · DOI
  30. 10.1021/ja104683w · DOI
  31. 10.1517/17425247.2012.682726 · DOI
  32. 10.1073/pnas.0914140107 · DOI
  33. 10.1038/nmat2992 · DOI
  34. 10.1016/j.nano.2011.01.002 · DOI
  35. 10.1371/journal.pone.0070072 · DOI
  36. 10.1038/srep02534 · DOI
  37. 10.1016/j.biomaterials.2011.12.043 · DOI

Cited by

Sorted by citations

See all 15

Metadata

Authors
Zhang, Q., Rajan, S. S., Tyner, K. M., Casey, B. J., Dugard, C. K., Jones, Y., Paredes, A. M., Clingman, C. S., Howard, P. C., & Goering, P. L.
Affiliations
  • Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration Silver Spring Maryland 20993
  • Office of Pharmaceutical Quality, Center for Drug Evaluation and Research, U.S. Food and Drug Administration Silver Spring Maryland 20993
  • Office of Scientific Coordination, National Center for Toxicological Research, U.S. Food and Drug Administration Jefferson Arkansas 72079
  • Office of Translational Sciences, Center for Drug Evaluation and Research, U.S. Food and Drug Administration Silver Spring Maryland 20993
Venue
Journal of Biomedical Materials Research Part B: Applied Biomaterials
Publisher
Wiley
Published
2015-05-26
Volume
104
Issue
5
Pages
1032-1042
ISSN
  • 1552-4973
  • 1552-4981
Cited by
15
References
2
Language
en
Funders
US Food and Drug Administration Office of Women's Health (750412CDH)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of iron oxide nanoparticles on biological responses and MR imaging properties in human mammary healthy and breast cancer epithelial cells. https://app.cochat.ai/papers/10.1002/jbm.b.33450
The paper
Zhang, Q., Rajan, S. S., Tyner, K. M., Casey, B. J., Dugard, C. K., Jones, Y., Paredes, A. M., Clingman, C. S., Howard, P. C., & Goering, P. L. (2016). Effects of iron oxide nanoparticles on biological responses and MR imaging properties in human mammary healthy and breast cancer epithelial cells. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.33450