The development of a micro‐shunt made from poly(styrene‐block‐isobutylene‐block‐styrene) to treat glaucoma
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Glaucoma is the second leading cause of blindness with ∼70 million people worldwide who are blind from this disease. The currently practiced trabeculectomy surgery, the gold standard treatment used to stop the progression of vision loss, is rather draconian, traumatic to the patient and requires much surgical skill to perform. This article summarizes the more than 10‐year development path of a novel device called the InnFocus MicroShunt®, which is a minimally invasive glaucoma drainage micro‐tube used to shunt aqueous humor from the anterior chamber of the eye to a flap formed under the conjunctiva and Tenon's Capsule. The safety and clinical performance of this device approaches that of trabeculectomy. The impetus to develop this device stemmed from the invention of a new biomaterial called poly(styrene‐block‐isobutylene‐block‐styrene), or “SIBS.” SIBS is ultra‐stable with virtually no foreign body reaction in the body, which manifests in the eye as clinically insignificant inflammation and capsule formation. The quest for an easier, safer, and more effective method of treating glaucoma led to the marriage of SIBS with this glaucoma drainage micro‐tube. This article summarizes the development of SIBS and the subsequent three iterations of design and four clinical trials that drove the one‐year qualified success rate of the device from 43% to 100%. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 211–221, 2017.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00538-9 · Cited by 2,780 · cited 2×
“Data from the AGIS study suggested that IOP must be reduced to the mid to low teens to stop the progression of vision loss.(33) In addition, the literature suggested that flow from the suprachoroidal space invariably ended up in the same episcleral and intrascleral veins as conventional flow via Schlemm’s Canal and if…”
MethodResultFluid Mechanics with Engineering Applications
Daugherty, R. L., & Franzini, J. B. (1965) · CERN Document Server (European Organization for Nuclear Research) · Cited by 911
Polyurethanes in Biomedical Applications
(2017) · Polyurethanes in Biomedical Applications · doi:10.1201/9780203742785-9 · Cited by 413
Three-Year Follow-up of the Tube Versus Trabeculectomy Study
Gedde, S. J., Schiffman, J. C., Feuer, W. J., Herndon, L. W., Brandt, J. D., & Budenz, D. L. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.06.018 · Cited by 380
Biodegradable Polymers and Plastics
(2003) · Springer eBooks · doi:10.1007/978-1-4419-9240-6 · Cited by 337
Medical applications of poly(styrene-block-isobutylene-block-styrene) (“SIBS”)
Pinchuk, L., Wilson, G. J., Barry, J. J., Schoephoerster, R. T., Parel, J.-M., & Kennedy, J. P. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.09.041 · Cited by 315 · cited 3×
“A more comprehensive description of SIBS and various applications were published by Pinchuk et al.25”
MethodSelf-citationJasty, M., Goetz, D. D., Bragdon, C. R., Lee, K. R., HANSON, A. E., Elder, J. R., & Harris, W. H. (1997) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199703000-00005 · Cited by 278
Pinchuk, L. (1995) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856294x00347 · Cited by 252
Self-citationThe UHMWPE Handbook: Ultra-High Molecular Weight Polyethylene in Total Joint Replacement
Kurtz, S. M. (2004) · Cited by 219
Hydrostatic pressure of the suprachoroidal space.
Emi, K., Pederson, J. E., & Toris, C. B. (1989) · PubMed · Cited by 195
An FTIR–ATR investigation of in vivo poly(ether urethane) degradation
Wu, Y., Sellitti, C., Anderson, J. M., Hiltner, A., Lodoen, G. A., & Payet, C. R. (1992) · Journal of Applied Polymer Science · doi:10.1002/app.1992.070460202 · Cited by 118
Final 5-Year Results of the TAXUS II Trial
Silber, S., Colombo, A., BANNING, A. P., Hauptmann, K. E., Drzewiecki, J., Grube, E., Dudek, D., & Baim, D. S. (2009) · Circulation · doi:10.1161/circulationaha.109.849877 · Cited by 108 · cited 1×
“The first medical use of SIBS was for Boston Scientific Corporation’s (Natick, MA) TAXUSVR stent.(25,26) TAXUS is a small balloon-expandable metallic stent (2–3 mm in diameter and 10–20 mm long), with a SIBS coating that slowly releases the antiproliferative drug, paclitaxel, into the wall of the coronary artery to pr…”
MethodBiocompatibility of implant materials: A review and scanning electron microscopic study
Apple, D. J., Mamalis, N., Brady, S. E., Loftfield, K., Norman, D. K., & Olson, R. J. (1984) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0146-2776(84)80079-8 · Cited by 107
Zhao, Q., Casas‐Bejar, J., Urbanski, P., & Stokes, K. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290406 · Cited by 77
Biostability of medical elastomers: a review
Vondráček, P., & Doležel, B. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90017-6 · Cited by 67
From thermoplastic elastomers to designed biomaterials
Kennedy, J. P. (2005) · Journal of Polymer Science Part A Polymer Chemistry · doi:10.1002/pola.20844 · Cited by 53 · cited 2×
“Living cationic polymerization, a seminal discovery in polymer science, led not only to SIBS but also to many novel compositions useful for a variety of industrial and medical applications.(18) The synthesis of SIBS (Figure 2) begins with a bifunctional initiator, which becomes part of the polymer.”
BackgroundKrohn, J., & Bertelsen, T. (1998) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.1998.760502.x · Cited by 43 · cited 1×
“In addition, the literature suggested that flow from the suprachoroidal space invariably ended up in the same episcleral and intrascleral veins as conventional flow via Schlemm’s Canal and if these downstream scleral veins were the source of high resistance, then they needed to be bypassed.(34) The option of draining…”
BackgroundHuang, C., Wang, H., Pan, J., Zhou, D., Chen, W., Li, W. S., Chen, Y., & Liu, Z. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-14504 · Cited by 25 · cited 1×
“available, with similar efficacy to trabeculectomy and with a better safety profile, it would be used earlier in the treatment paradigm for glaucoma, before the cornea and conjunctiva were irreversibly damaged by the preservatives in glaucoma medications.(30) Trabeculectomy is a surgical procedure where the conjunctiv…”
Method
Metadata
- Authors
- Pinchuk, L., Riss, I., Batlle, J. F., Kato, Y. P., Martin, J. B., Arrieta, E., Palmberg, P., Parrish, R. K., Weber, B. A., Kwon, Y., & Parel, J.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2015-09-18
- Volume
- 105
- Issue
- 1
- Pages
- 211-221
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W1893203835
- Cited by
- 160
- References
- 18
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.