CoChat

Quality control of bone densitometry in a national health survey (NHANES III) using three mobile examination centers

Wahner, Heinz W., Looker, Anne, Dunn, William L., Walters, Lana C., Hauser, Mary F., Novak, Catherine · 1994 · Journal of Bone and Mineral Research
Cited by 146

The DOI matches its Crossref record.

Abstract

A quality control (QC) program for bone mineral measurements at the proximal femur by dual-energy x-ray absorptiometry (DXA) was designed for the osteoporosis component of the Third National Health and Nutrition Examination Survey (NHANES III). Major elements of the QC program are (1) a QC center for review of all scans, (2) setup procedures for and continuous monitoring of daily QC procedures, (3) reference standards for cross-calibration, (4) longitudinal studies for assessment of instrument stability, (5) monitoring of technologist performance, and (6) training. This report describes the results of the QC program of the first half of this 6 year study, which began in 1988. Measurements were performed on 7376 subjects in three mobile examination centers, which traveled to a new location about every 3 months, a total of 44 locations. A small percentage (3.5%) of all scans were rejected, mostly because of patient motion during scanning, but 33% of the remaining scans required reanalysis at the QC center to refine the location of the regions of interest. Precision in spine and hip phantoms was below 1% at all ROIs. In 535 subjects with duplicate scans, age 20–91 of both sexes, examined in a blinded review, precision for BMD at the femur neck ROI was 3.2% (CV) and 5.1% for Ward's triangle BMD. The central review improved scan quality, increased the number of usable scans, and reduced significantly the range of the mean percentage difference in the duplicate scans. Minor alterations in machine function were observed and corrected. QC results on phantoms were similar to those obtained with stationary instruments in dedicated laboratories. Retrospective analysis of the regression slopes from QC records did not show a need for correction of the data base, indicating that the instruments were stable during the course of the study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbmr.5650090621

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 146

Metadata

Authors
Wahner, H. W., Looker, A., Dunn, W. L., Walters, L. C., Hauser, M. F., & Novak, C.
Venue
Journal of Bone and Mineral Research
Published
1994-06-01
Volume
9
Issue
6
Pages
951-960
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2095063781
Cited by
146
References
0
FWCI
4.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality control of bone densitometry in a national health survey (NHANES III) using three mobile examination centers. https://app.cochat.ai/papers/10.1002/jbmr.5650090621
The paper
Wahner, H. W., Looker, A., Dunn, W. L., Walters, L. C., Hauser, M. F., & Novak, C. (1994). Quality control of bone densitometry in a national health survey (NHANES III) using three mobile examination centers. Journal of Bone and Mineral Research. https://doi.org/10.1002/jbmr.5650090621

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.