The DOI matches its Crossref record.
Evaluation of cortical bone by computed tomography
Abstract
The purpose of this study was to determine the minimum thickness of cortical bone required for the accurate measurement of cortical material density by computed tomography (CT) and to establish normal reference values. A phantom with several wall thicknesses of bone-like material was constructed to simulate various cortical widths. The CT density at each level of thickness was measured on a GE 9800 CT scanner and on the OsteoQuant, a special CT scanner optimized for the measurement of bone in the extremities. The minimum width required to attain the correct material density was determined for each scanner. Additionally, the material density and width of the cortex in the radius and/or femur were measured by CT in 761 healthy subjects, ages 4-84 years. The minimum thickness necessary for an accurate density evaluation of the walls of the phantom by CT was 2-2.5 mm; below these thresholds the values fell in a linear way relative to width. In humans, the material density of cortical bone in the appendicular skeleton was not influenced by height or weight, and the values were similar for all subjects, as long as the cortical width was above 2-2.5 mm. The cortical width increased with age up to 30 years and decreased from 50 years on. We conclude that the material density of cortical bone in the appendicular skeleton can be measured accurately by CT if the thickness of the cortex exceeds 2-2.5 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Engelke, K., Adams, J. E., Armbrecht, G., Augat, P., Bogado, C. E., Bouxsein, M. L., Felsenberg, D., Ito, M., Prevrhal, S., Hans, D. B., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.010 · Cited by 617
Peacock, M., Turner, C. H., Econs, M. J., & Foroud, T. (2002) · Endocrine Reviews · doi:10.1210/edrv.23.3.0464 · Cited by 468
Relation between age, femoral neck cortical stability, and hip fracture risk
Mayhew, P. M., Thomas, C. D., Clement, J. G., Loveridge, N., Beck, T. J., Bonfield, W., Burgoyne, C. J., & Reeve, J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)66870-5 · Cited by 397
Reciprocal relations of subcutaneous and visceral fat to bone structure and strength
Gilsanz, V., Chalfant, J., Mo, A. O., Lee, D. C., Dorey, F. J., & Mittelman, S. D. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-2422 · Cited by 351
Self-citationEser, P., Frotzler, A., Zehnder, Y., Wick, L., Knecht, H., Denoth, J., & Schiessl, H. (2004) · Bone · doi:10.1016/j.bone.2004.01.001 · Cited by 323
Metadata
- Authors
- Hangartner, T. N., & Gilsanz, V.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-10-01
- Volume
- 11
- Issue
- 10
- Pages
- 1518-1525
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2054551985
- Cited by
- 209
- References
- 0
- FWCI
- 12.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of cortical bone by computed tomography. https://app.cochat.ai/papers/10.1002/jbmr.5650111019
- The paper
- Hangartner, T. N., & Gilsanz, V. (1996). Evaluation of cortical bone by computed tomography. Journal of Bone and Mineral Research. https://doi.org/10.1002/jbmr.5650111019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.