Rapid screening assay of congenital adrenal hyperplasia by measuring 17α‐hydroxyprogesterone with high‐performance liquid chromatography/electrospray ionization tandem mass spectrometry from dried blood spots
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A rapid, simple, and specific method was developed for the diagnosis of congenital adrenal hyperplasia (CAH) from dried blood spots on newborn screening cards based on high‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS). The usefulness of 17α‐hydroxyprogesterone (17OH‐P) determination on dried filter‐paper blood samples from patients with CAH caused by 21‐hydroxylase deficiency was evaluated. The LC/MS/MS detection of 17OH‐P was rapid, <4 min. The intra‐ and interday accuracy and precision of the method were <7%. Our procedure maintained good linearities (R 2 > 0.992) and recovery rate (>83%). We used this new method to directly determine the 17OH‐P levels in dried blood specimens from abnormal children of various ages, with a detection limit of 20 ng/ml (∼240 pg), to avoid the time‐consuming derivatization steps required by the gas‐chromatography/mass spectrometry (GC/MS) method. Four dried filter‐paper blood samples of CAH patients (three girls and one boy, 1–14 years old) were all quantified in an LC/MS/MS study and revealed high 17OH‐P levels (>90 ng/ml). After treatment, all of the elevated 17OH‐P levels either decreased or disappeared. Compared with CAH patients, 17OH‐P was nearly undetectable (<20 ng/ml) in the normal infants by LC/MS/MS. This LC/MS/MS assay is not only useful for both diagnosis and monitoring of treatment of CAH in all other age groups, it also can be used as a screening test for CAH infants. In this study, we provided the first data on 17OH‐P in dried blood specimens affected with CAH using HPLC/ESI‐MS/MS. J. Clin. Lab. Anal. 16:20–25, 2002. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pang, S., Wallace, M. A., Hofman, L., Thuline, H. C., Dorche, C., Lyon, I. C. T., Dobbins, R. H., Kling, S., Fujieda, K., & Suwa, S. (1988) · Journal of Urology · doi:10.1016/s0022-5347(17)42164-1 · Cited by 392
Wong, T., Shackleton, C. H., Covey, T. R., & Ellis, G. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1830 · Cited by 159
Wudy, S. A., Wachter, U. A., Homoki, J., & Teller, W. M. (1995) · Pediatric Research · doi:10.1203/00006450-199507000-00013 · Cited by 69
Cited by
Dried blood spot sampling in combination with LC‐MS/MS for quantitative analysis of small molecules
Li, W., & Tse, F. L. S. (2010) · Biomedical Chromatography · doi:10.1002/bmc.1367 · Cited by 599
Lacey, J. M., Minutti, C. Z., Magera, M. J., Tauscher, A. L., Casetta, B., McCann, M., Lymp, J., Hahn, S. H., Rinaldo, P., & Matern, D. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.027193 · Cited by 216
Janzen, N., Peter, M., Sander, S., Steuerwald, U., Terhardt, M., Holtkamp, U., & Sander, J. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-2890 · Cited by 211
Development and Performance Evaluation of a Tandem Mass Spectrometry Assay for 4 Adrenal Steroids
Kushnir, M. M., Rockwood, A. L., Roberts, W. L., Pattison, E. G., Owen, W. E., Bunker, A. M., & Meikle, A. W. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.068445 · Cited by 125
Metadata
- Authors
- Lai, C., Tsai, C., Tsai, F., Wu, J., Lin, W., & Lee, C.
- Venue
- Journal of Clinical Laboratory Analysis
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 16
- Issue
- 1
- Pages
- 20-25
- ISSN
- 0887-8013 (ISSN-L)
- 1098-2825
- OpenAlex
- W2014440976
- Cited by
- 34
- References
- 3
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.