CoChat

Rapid screening assay of congenital adrenal hyperplasia by measuring 17α‐hydroxyprogesterone with high‐performance liquid chromatography/electrospray ionization tandem mass spectrometry from dried blood spots

Open access
Lai, Chien‐Chen, Tsai, Chang‐Hai, Tsai, Fuu‐Jen, Wu, Jer‐Yuarn, Lin, Wei‐De, Lee, Cheng‐Chun · 2002 · Journal of Clinical Laboratory Analysis
Cited by 34

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A rapid, simple, and specific method was developed for the diagnosis of congenital adrenal hyperplasia (CAH) from dried blood spots on newborn screening cards based on high‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS). The usefulness of 17α‐hydroxyprogesterone (17OH‐P) determination on dried filter‐paper blood samples from patients with CAH caused by 21‐hydroxylase deficiency was evaluated. The LC/MS/MS detection of 17OH‐P was rapid, <4 min. The intra‐ and interday accuracy and precision of the method were <7%. Our procedure maintained good linearities (R 2 > 0.992) and recovery rate (>83%). We used this new method to directly determine the 17OH‐P levels in dried blood specimens from abnormal children of various ages, with a detection limit of 20 ng/ml (∼240 pg), to avoid the time‐consuming derivatization steps required by the gas‐chromatography/mass spectrometry (GC/MS) method. Four dried filter‐paper blood samples of CAH patients (three girls and one boy, 1–14 years old) were all quantified in an LC/MS/MS study and revealed high 17OH‐P levels (>90 ng/ml). After treatment, all of the elevated 17OH‐P levels either decreased or disappeared. Compared with CAH patients, 17OH‐P was nearly undetectable (<20 ng/ml) in the normal infants by LC/MS/MS. This LC/MS/MS assay is not only useful for both diagnosis and monitoring of treatment of CAH in all other age groups, it also can be used as a screening test for CAH infants. In this study, we provided the first data on 17OH‐P in dried blood specimens affected with CAH using HPLC/ESI‐MS/MS. J. Clin. Lab. Anal. 16:20–25, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jcla.2039

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 34

Metadata

Authors
Lai, C., Tsai, C., Tsai, F., Wu, J., Lin, W., & Lee, C.
Venue
Journal of Clinical Laboratory Analysis
Publisher
Wiley
Published
2002-01
Volume
16
Issue
1
Pages
20-25
ISSN
  • 0887-8013 (ISSN-L)
  • 1098-2825
OpenAlex
W2014440976
Cited by
34
References
3
FWCI
0.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.