Cited by 44Cardiac Ischemia and ReperfusionHeat shock proteins researchElectromagnetic Fields and Biological Effects

Myocardial function improved by electromagnetic field induction of stress protein hsp70

Open access
George, Isaac, Geddis, Matthew S., Lill, Zachary, Lin, Hana, Gomez, Teodoro, Blank, Martin, Oz, Mehmet C., Goodman, Reba·2008·Journal of Cellular Physiology

Abstract

Studies on myocardial function have shown that hsp70, stimulated by an increase in temperature, leads to improved survival following ischemia‐reperfusion (I‐R). Low frequency electromagnetic fields (EMFs) also induce the stress protein hsp70, but without elevating temperature. We have examined the hemodynamic changes in concert with EMF pre‐conditioning and the induction of hsp70 to determine whether improved myocardial function occurs following I‐R injury in Sprague–Dawley rats. Animals were exposed to EMF (60 Hz, 8 µT) for 30 min prior to I‐R. Ischemia was then induced by ligation of left anterior descending coronary artery (LAD) for 30 min, followed by 30 min of reperfusion. Blood and heart tissue levels for hsp70 were determined by Western blot and RNA transcription by rtPCR. Significant upregulation of the HSP70 gene and increased hsp70 levels were measured in response to EMF pre‐exposures. Invasive hemodynamics, as measured using a volume conductance catheter, demonstrated significant recovery of systolic contractile function after 30 min of reperfusion following EMF exposure. Additionally, isovolemic relaxation, a measure of ventricular diastolic function, was markedly improved in EMF‐treated animals. In conclusion, non‐invasive EMF induction of hsp70 preserved myocardial function and has the potential to improve tolerance to ischemic injury. J. Cell. Physiol. 216: 816–823, 2008, © 2008 Wiley‐Liss, Inc.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jcp.21461

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Coherent fields, including pulsed ELFs, upregulate HSP70, improve ischemia-reperfusion recovery, and enhance antioxidant effects.

    “coherent fields, including pulsed ELFs, upregulate heat shock protein 70 (HSP70), improve ischemia–reperfusion recovery, and enhance antioxidant effects [25,79,80,81]”

    From The Heart’s Electromagnetic Field in Emotions, Empathy and Human Connection: Biosensor-Derived Insights into Heart–Brain Axis Mechanisms and a Basis for Novel BioMagnetoTherapies (2026) · cites this paper as [80]

    The Abstract and Discussion report that pre-exposure to a 60 Hz electromagnetic field increased HSP70 and improved cardiac function after ischemia–reperfusion in rats. The Methods describe a 60 Hz field, not a pulsed or specifically coherent field. The paper discusses prior findings on resistance to oxidation, but does not report an antioxidant effect from its own EMF exposure. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
George, I., Geddis, M. S., Lill, Z., Lin, H., Gomez, T., Blank, M., Oz, M. C., & Goodman, R.
Affiliations
Columbia University Irving Medical Center (US)
Corresponding author
Goodman, Reba
Venue
Journal of Cellular Physiology
Publisher
Wiley
Published
2008-04-29
Volume
216
Issue
3
Pages
816-823
ISSN
  • 0021-9541 (ISSN-L)
  • 1097-4652
OpenAlex
W1982718433
Cited by
44
References
54
Citations by year
2026: 3 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 1 · 2019: 3 · 2018: 2 · 2017: 2 · 2016: 3 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 4
FWCI
3.56
Type
journal article
Language
en
Open access
Locations
  • Journal of Cellular Physiology (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health
  • National Heart, Lung, and Blood Institute (T32-HL-07854, T32HL007854)
Topics
  • Health Sciences › Medicine › Pathology and Forensic Medicine › Cardiac Ischemia and Reperfusion
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Heat shock proteins research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
Keywords
HSP70, heat shock proteins, low-frequency electromagnetic fields, myocardial ischemia-reperfusion injury, cardioprotection, cardiac contractility, diastolic function, ischemic preconditioning, coronary artery ligation
MeSH terms
Aged, Animals, Electromagnetic Fields, Female, Hemodynamics, Humans, Male, Myocardial Contraction, Myocardium, Reperfusion Injury, Rats, Sprague-Dawley, HSP70 Heat-Shock Proteins, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review