Dual energy X‐ray absorptiometry: gold standard for muscle mass?
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Since the late 90s, dual energy X-ray absorptiometry (DXA) has been validated against so-called gold standards for body composition (BC) by comparison to chemical analysis, dissection, and anatomy-based imaging methods (CT or MRI).1-3 Today, DXA is being used in a variety of clinical settings with the prospect of diagnosing osteoporosis, obesity, and sarcopenia. With this in mind, we read with great interest the article ‘Pitfalls in the measurement of muscle mass: a need for a reference standard’.4 This paper states that DXA is a gold standard for the measurement of muscle mass on behalf of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis working group on frailty and sarcopenia. Lean soft tissue mass by DXA has proved to be a reliable method for the estimation of muscle mass in groups using prediction equations.1 Individual discrepancies related to lean tissue hydration and tissue thickness have been repeatedly reported in literature.5-7 Because of its imprecise definition, lean or lean body mass (LBM) leads to much confusion in the literature and is often erroneously used as a synonym for fat-free mass (FFM). In attempts to identify physiological relevant tissues, the concept of LBM has been introduced almost 8 decades ago.8 LBM was used to represent the body's active protoplasm (i.e. bone salts, essential lipoids, and tissue each with their specific gravity). LBM and FFM are not interchangeable as the former consists of the FFM plus the essential fat which may vary from 2 to 10% for the FFM.9, 10 DXA pretends to measure lean or LBM as opposed to FFM.2 However, DXA produces results also for fat (essential and non-essential lipids) and bone mineral content (dry salts). Thus, lean mass by DXA compares to FFM minus bone minerals. As a result, lean by DXA is quantitatively smaller than FFM which in turn is smaller than LBM.5 This confusion in terminology adds to the ongoing difficulties with the interpretation of BC output produced by different methodologies. The authors state that in a previous study, the agreement between appendicular lean mass assessed by DXA and predicted by bio-electrical impedance analysis (BIA) was found to be low with a potential large prediction error on the individual level. Comparing two indirect BC methods to each other with the purpose of validation is subject to misinterpretation. Both methods are often used to estimate FFM, notwithstanding they may represent different compartments. Compartments different from FFM may be typically estimated depending on which BC technique was used to develop the BIA system's equation.11 As such, the systematic underestimation of LBM measurements by BIA as reported in the present paper might not be valid.4 In fact, recent evidence suggests that when using raw BIA data (resistance and reactance) to produce population specific equations, BIA rather overestimates DXA in subjects with low muscularity.12, 13 This observation, of course, does not ignore the fact that prediction errors at individual level remain possible. Fundamental research has proven that lean mass by DXA is almost equal to the sum of muscle, skin, and viscera by dissection.2 Lipid-free skeletal muscle by underwater weighing has been estimated at 1.04 g/cm3 and skin at 1.07 g/cm3 in an older sample.3 Since CT or MRI cannot distinguish between intramyocellular lipids, the use of a constant density to convert volume to weight is prone to interindividual variation. This is also the case when lean mass by DXA is used as a synonym for muscle mass, taking into account the variation of water, protein, and glycogen content in a limb and between different tissue compartments. As lean and muscle belong to two different organization levels of BC, their interrelationship remains predictive with a given residual uncertainty.14 In summary, the clinical interpretation of DXA outcome measures may lead to elevated expectations regarding the diagnosis of sarcopenia. As long as there is no clarity about the way manufacturers use their mathematical algorithms to produce quantitative results, the status of gold standard for DXA is premature. Upgrading DXA to gold standard for muscle mass measurement opens the doorway to inaccurate validation of other indirect BC techniques by DXA (e.g. ultrasound). Moreover, this may create unreliable diagnoses in clinical settings. In patients, the cumulative impact of biological variability on muscle mass measurement is not yet established. The authors declare that no conflict of interest relevant to this letter exists. The authors confirm that they comply with the ethical guidelines for authorship and publishing in the Journal of Cachexia, Sarcopenia and Muscle.15
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pitfalls in the measurement of muscle mass: A need for a reference standard
Buckinx, F., Landi, F., Cesari, M., Fielding, R. A., Visser, M., Engelke, K., Maggi, S., Dennison, E., Al‐Daghri, N. M., Allepaerts, S., et al. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12268 · Cited by 765
Total-body skeletal muscle mass: Estimation by a new dual-energy X-ray absorptiometry method
Kim, J., Wang, Z., Heymsfield, S. B., Baumgartner, R. N., & Gallagher, D. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.2.378 · Cited by 737
The five-level model: a new approach to organizing body-composition research
Wang, Z., Pierson, R., & Heymsfield, S. (1992) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/56.1.19 · Cited by 729 · cited 1×
“As lean and muscle belong to two different organization levels of BC, their interrelationship remains predictive with a given residual uncertainty.(14)”
BackgroundDual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
Sergi, G., De Rui, M., Veronese, N., Bolzetta, F., Berton, L., Carraro, S., Bano, G., Coin, A., Manzato, E., & Perissinotto, E. (2015) · Clinical Nutrition · doi:10.1016/j.clnu.2014.07.010 · Cited by 467 · cited 1×
“cific equations, BIA rather overestimates DXA in subjects with low muscularity.(12,13) This observation, of course, does not ignore the fact that prediction errors at individual level”
BackgroundScafoglieri, A., Clarys, J. P., Bauer, J. M., Verlaan, S., Van Malderen, L., Vantieghem, S., Cederholm, T., Sieber, C. C., Mets, T., & Bautmans, I. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2016.04.026 · Cited by 65 · cited 1×
“cific equations, BIA rather overestimates DXA in subjects with low muscularity.(12,13) This observation, of course, does not ignore the fact that prediction errors at individual level”
BackgroundSelf-citationAssessment of regional adipose tissue depots: a DXA and CT comparison in cadavers of elderly persons
Scafoglieri, A., Deklerck, R., Tresignie, J., De Mey, J., Clarys, J. P., & Bautmans, I. (2013) · Experimental Gerontology · doi:10.1016/j.exger.2013.07.005 · Cited by 25 · cited 1×
“07 g/cm(3) in an older sample.(3) Since CT or MRI cannot distinguish between intramyocellular lipids, the use of a constant density”
BackgroundSelf-citation
Cited by
Measuring Muscle Mass and Strength in Obesity: a Review of Various Methods
Sizoo, D., de Heide, L. J. M., Emous, M., van Zutphen, T., Navis, G., & van Beek, A. P. (2021) · Obesity Surgery · doi:10.1007/s11695-020-05082-2 · Cited by 77
Duchowny, K. A., Peters, K. E., Cummings, S. R., Orwoll, E. S., Hoffman, A. R., Ensrud, K. E., Cauley, J. A., Evans, W. J., Cawthon, P. M., & for the Osteoporotic Fractures in Men (MrOS) Study Research Group (2020) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12494 · Cited by 54
Zhu, K., Wactawski-Wende, J., Ochs-Balcom, H. M., LaMonte, M. J., Hovey, K. M., Evans, W., Shankaran, M., Troen, B. R., & Banack, H. R. (2021) · The Journals of Gerontology: Series A · doi:10.1093/gerona/glab020 · Cited by 37
Metadata
- Authors
- Scafoglieri, A., & Clarys, J. P.
- Venue
- Journal of Cachexia, Sarcopenia and Muscle
- Publisher
- Wiley
- Published
- 2018-05-22
- Volume
- 9
- Issue
- 4
- Pages
- 786-787
- ISSN
- 2190-5991 (ISSN-L)
- 2190-6009
- OpenAlex
- W2803544910
- Cited by
- 109
- References
- 7
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.