Ultrasonic fetal weight estimation: Analysis of inter‐ and intra‐observer variability
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Standard ultrasound measurements were performed by two observers in 40 third‐trimester fetuses. Observers were blinded to the results of the meaurements. Estimated fetal weight (EFW) was calculated using two published formulae. The intra‐observer standard deviation for EFW, assessed using one‐way analysis of variance, was <75 g for both observers. The 95% prediction intervals for inter‐observer comparisons of EFW, calculated using the limits of agreement method, were − 187.3 g to 139.8 g, and − 159.9 g to 124.3 g, using the two formulae. The results suggest that measurements of EFW are reproducible. The prediction interval is comparable to the weekly fetal weight increment in normal fetuses. © 1993 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682
The estimation of fetal weight by computer-assisted analysis
Warsof, S. L., Gohari, P., Berkowitz, R. L., & Hobbins, J. C. (1977) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(77)90058-8 · Cited by 355
Cited by
A systematic review of the ultrasound estimation of fetal weight
Dudley, N. J. (2005) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1751 · Cited by 537
Fetal growth: a review of terms, concepts and issues relevant to obstetrics
Mayer, C., & Joseph, K. S. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.11204 · Cited by 242
Intra‐ and interobserver variability in fetal ultrasound measurements
Sarris, I., Ioannou, C., Chamberlain, P., Ohuma, E., Roseman, F., Hoch, L., Altman, D. G., Papageorghiou, A. T., & for the International Fetal and Newborn Growth Consortium for the 21 Century (INTERGROWTH‐21) (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10082 · Cited by 195
The importance of quality management in fetal measurement
Dudley, N. J., & Chapman, E. (2002) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.0960-7692.2001.00549.x · Cited by 94
“A number of groups have reported interobserver variability (coefficient of variation) in the range 2–3% 16–18 .”
Background
Metadata
- Authors
- Chang, T. C., Robson, S. C., Spencer, J. A. D., & Gallivan, S.
- Venue
- Journal of Clinical Ultrasound
- Publisher
- Wiley
- Published
- 1993-10
- Volume
- 21
- Issue
- 8
- Pages
- 515-519
- ISSN
- 0091-2751 (ISSN-L)
- 1097-0096
- OpenAlex
- W2045919400
- Cited by
- 51
- References
- 3
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonic fetal weight estimation: Analysis of inter‐ and intra‐observer variability. https://app.cochat.ai/papers/10.1002/jcu.1870210808
- The paper
- Chang, T. C., Robson, S. C., Spencer, J. A. D., & Gallivan, S. (1993). Ultrasonic fetal weight estimation: Analysis of inter‐ and intra‐observer variability. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.1870210808
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.