Reproducibility of 3‐dimensional sonographic measurements of fetal and placental volume at gestational ages of 11–18 weeks
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose.: Determine the reproducibility of 3D ultrasound (3DUS) measurements of fetal and placental volumes. Methods.: We included 34 pregnant women between gestational weeks (GW) 11–18. Two operators independently acquired fetal and placental volumes using 3DUS. Each volume was acquired twice and stored on disk for off‐line analysis. Intra‐ and interobserver reproducibility was expressed in the intra‐ and interclass correlation coefficient (intra‐CC and inter‐CC). In addition, the 3DUS volumes acquired by the first operator were calculated by the second and vice‐versa to evaluate the effect of volume acquisition and caliper placement. A value >0.75 was considered a good agreement. Results.: Fetal and placental volume measurements were successful in 97% of all cases. Between GW 11–14 and 14–18 the median fetal volume was 20.8 (5.0–35.1) and 51.7 (37.9–132.8) ml, the median placental volume was 71.3 (40.9–111.9) and 120.7 (94.2– 273.7) ml. Bland‐Altman plots were used for statistical analysis. The intraobserver reproducibility was good for fetus (intra‐CC: 0.99; 0.99) and placenta (intra‐CC: 0.99; 0.98). Also, interobserver reproducibility was good for fetus (inter‐CC 0.98) and placenta (inter‐CC 0.98). In addition, regardless of the operator who acquired the volumes, the inter‐CC remained good for both fetus (inter‐CC: 0.99; 0.99) and placenta (inter‐CC: 0.97; 0.99). Conclusion.: The reproducibility of fetal and placental volume measurements by 3DUS between GW 11–18 is good. In addition, individually chosen caliper placement and volume acquisition has no effect on the calculation of either volumes. © 2007 Wiley Periodicals, Inc. J Clin Ultrasound, 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Wegrzyn, P., Faro, C., Falcon, O., Peralta, C. F. A., & Nicolaides, K. H. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1923 · Cited by 103
Metzenbauer, M., Hafner, E., Schuchter, K., & Philipp, K. (2002) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2002.00655.x · Cited by 79
Cited by
Reus, A. D., El-Harbachi, H., Rousian, M., Willemsen, S. P., Steegers-Theunissen, R. P. M., Steegers, E. A. P., & Exalto, N. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13197 · Cited by 46
Jones, N. W., Raine-Fenning, N. J., Mousa, H. A., Bradley, E., & Bugg, G. J. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.11.018 · Cited by 32
“technically difficult to acquire the placental as a whole volume within a single 3-D volume sweep (Deurloo et al. 2007).”
BackgroundSur, S. D., Jayaprakasan, K., Jones, N. W., Clewes, J., Winter, B., Cash, N., Campbell, B., & Raine-Fenning, N. J. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.03.006 · Cited by 18
(2015) · PubMed Central · Cited by 3
Metadata
- Authors
- Deurloo, K., Spreeuwenberg, M., Rekoert‐Hollander, M., & van Vugt, J.
- Venue
- Journal of Clinical Ultrasound
- Publisher
- Wiley
- Published
- 2007-02
- Volume
- 35
- Issue
- 3
- Pages
- 125-132
- ISSN
- 0091-2751 (ISSN-L)
- 1097-0096
- OpenAlex
- W2071968285
- Cited by
- 33
- References
- 3
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of 3‐dimensional sonographic measurements of fetal and placental volume at gestational ages of 11–18 weeks. https://app.cochat.ai/papers/10.1002/jcu.20306
- The paper
- Deurloo, K., Spreeuwenberg, M., Rekoert‐Hollander, M., & van Vugt, J. (2007). Reproducibility of 3‐dimensional sonographic measurements of fetal and placental volume at gestational ages of 11–18 weeks. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.20306
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.