The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fluorescence lifetime imaging by time‐correlated single‐photon counting
Open accessAbstract
We present a time‐correlated single photon counting (TCPSC) technique that allows time‐resolved multi‐wavelength imaging in conjunction with a laser scanning microscope and a pulsed excitation source. The technique is based on a four‐dimensional histogramming process that records the photon density over the time of the fluorescence decay, the x‐y coordinates of the scanning area, and the wavelength. The histogramming process avoids any time gating or wavelength scanning and, therefore, yields a near‐perfect counting efficiency. The time resolution is limited only by the transit time spread of the detector. The technique can be used with almost any confocal or two‐photon laser scanning microscope and works at any scanning rate. We demonstrate the application to samples stained with several dyes and to CFP‐YFP FRET. Microsc. Res. Tech. 63:58–66, 2004. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
The Phasor Approach to Fluorescence Lifetime Imaging Analysis
Digman, M. A., Caiolfa, V. R., Zamai, M., & Gratton, E. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120154 · Cited by 1,145
Long-Lived Emissive Probes for Time-Resolved Photoluminescence Bioimaging and Biosensing
Zhang, K. Y., Yu, Q., Wei, H., Liu, S., Zhao, Q., & Huang, W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00425 · Cited by 923
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Self-citationImaging protein molecules using FRET and FLIM microscopy
Wallrabe, H., & Periasamy, A. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.002 · Cited by 724
Metadata
- Authors
- Becker, W., Bergmann, A., Hink, M. A., König, K., Benndorf, K., & Biskup, C.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 2003-12-10
- Volume
- 63
- Issue
- 1
- Pages
- 58-66
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W2090663204
- Cited by
- 513
- References
- 1
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence lifetime imaging by time‐correlated single‐photon counting. https://app.cochat.ai/papers/10.1002/jemt.10421
- The paper
- Becker, W., Bergmann, A., Hink, M. A., König, K., Benndorf, K., & Biskup, C. (2004). Fluorescence lifetime imaging by time‐correlated single‐photon counting. Microscopy Research and Technique. https://doi.org/10.1002/jemt.10421
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.