Fluorescence lifetime imaging by time‐correlated single‐photon counting
Open accessAbstract
We present a time‐correlated single photon counting (TCPSC) technique that allows time‐resolved multi‐wavelength imaging in conjunction with a laser scanning microscope and a pulsed excitation source. The technique is based on a four‐dimensional histogramming process that records the photon density over the time of the fluorescence decay, the x‐y coordinates of the scanning area, and the wavelength. The histogramming process avoids any time gating or wavelength scanning and, therefore, yields a near‐perfect counting efficiency. The time resolution is limited only by the transit time spread of the detector. The technique can be used with almost any confocal or two‐photon laser scanning microscope and works at any scanning rate. We demonstrate the application to samples stained with several dyes and to CFP‐YFP FRET. Microsc. Res. Tech. 63:58–66, 2004. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Time-Correlated Single Photon Counting
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-524140-3.x5001-1 · Cited by 2,550
Memoir on inventing the confocal scanning microscope
Minsky, M. (1988) · Scanning · doi:10.1002/sca.4950100403 · Cited by 1,556
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Self-citationWhite, J. G., Amos, W. B., & Fordham, M. (1987) · The Journal of cell biology · doi:10.1083/jcb.105.1.41 · Cited by 858
Targeted transfection by femtosecond laser
Tirlapur, U. K., & König, K. (2002) · Nature · doi:10.1038/418290a · Cited by 622
Self-citationTopics in Fluorescence Spectroscopy: Principles
(2002) · Springer eBooks · doi:10.1007/b112907 · Cited by 589
Koenig, K., & Riemann, I. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1577349 · Cited by 535
Photobleaching in Two-Photon Excitation Microscopy
Patterson, G. H., & Piston, D. W. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76762-2 · Cited by 527
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
How many photons are necessary for fluorescence-lifetime measurements?
Köllner, M., & Wolfrum, J. (1992) · Chemical Physics Letters · doi:10.1016/0009-2614(92)87068-z · Cited by 366
Geddes, C. D., Cao, H., Gryczyński, I., Gryczynski, Z. K., Fang, J., & Lakowicz, J. R. (2003) · The Journal of Physical Chemistry A · doi:10.1021/jp022040q · Cited by 282
Ballew, R. M., & Demas, J. N. (1989) · Analytical Chemistry · doi:10.1021/ac00176a007 · Cited by 262
Gratton, E. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1586704 · Cited by 260
Probes for Detection of Specific DNA Sequences at the Single-Molecule Level
Knemeyer, J.-P., Marmé, N., & Sauer, M. (2000) · Analytical Chemistry · doi:10.1021/ac000024o · Cited by 252
Elangovan, M., Day, R. N., & Periasamy, A. (2002) · Journal of Microscopy · doi:10.1046/j.0022-2720.2001.00984.x · Cited by 232
Gerritsen, H. C., Asselbergs, M. A. H., Agronskaia, A. V., & Van Sark, W. G. J. H. M. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01031.x · Cited by 221
Intrinsic Fluorescence from DNA Can Be Enhanced by Metallic Particles
Lakowicz, J. R., Shen, B., Gryczynski, Z. K., D’Auria, S., & Gryczyński, I. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5445 · Cited by 210
Two‐photon excited lifetime imaging of autofluorescence in cells during UV A and NIR photostress
KÖNIG, K., SO, P. T. C., MANTULIN, W. W., TROMBERG, B. J., & GRATTON, E. (1996) · Journal of Microscopy · doi:10.1046/j.1365-2818.1996.910650.x · Cited by 209
Self-citation(2001) · Springer eBooks · doi:10.1007/978-1-4614-7513-2 · Cited by 208
Fluorescence lifetime imaging using a confocal laser scanning microscope
Buurman, E. P., Sanders, R., Draaijer, A., Gerritsen, H. C., van Veen, J. J. F., Houpt, P. M., & Levine, Y. K. (1992) · Scanning · doi:10.1002/sca.4950140305 · Cited by 190
Jakobs, S., Subramaniam, V., Schönle, A., Jovin, T. M., & Hell, S. W. (2000) · FEBS Letters · doi:10.1016/s0014-5793(00)01896-2 · Cited by 176
Theoretical investigation of the signal-to-noise ratio in fluorescence lifetime imaging
Philip, J., & Carlsson, K. (2003) · Journal of the Optical Society of America A · doi:10.1364/josaa.20.000368 · Cited by 158
Bacskai, B. J., Skoch, J. M., Hickey, G. A., Allen, R., & Hyman, B. T. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1584442 · Cited by 150
Time-resolved fluorescence microscopy using two-photon excitation
So, P. T. C., French, T. E., Yu, W., Berland, K. M., Dong, C. Y., & Gratton, E. (1995) · Bioimaging · doi:10.1002/1361-6374(199506)3:2<49::aid-bio1>3.0.co;2-e · Cited by 149
Time‐domain whole‐field fluorescence lifetime imaging with optical sectioning
Cole, M. J., Siegel, J., Webb, S. E. D., et al. (2001) · Journal of Microscopy · doi:10.1046/j.1365-2818.2001.00894.x · Cited by 146
Fluorescence lifetime imaging of oxygen in living cells
Gerritsen, H. C., Sanders, R., Draaijer, A., İnce, C., & Levine, Y. K. (1997) · Journal of Fluorescence · doi:10.1007/bf02764572 · Cited by 145
Straub, M., & Hell, S. W. (1998) · Applied Physics Letters · doi:10.1063/1.122276 · Cited by 137
Picosecond-Hetero-FRET Microscopy to Probe Protein-Protein Interactions in Live Cells
Tramier, M., Gautier, I., Piolot, T., et al. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75357-5 · Cited by 133
Multiple frequency fluorescence lifetime imaging microscopy
Squire, Verveer, & Bastiaens (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00651.x · Cited by 118
Berezovska, O., Ramdya, P. P., Skoch, J. M., Wolfe, M. S., Bacskai, B. J., & Hyman, B. T. (2003) · Journal of Neuroscience · doi:10.1523/jneurosci.23-11-04560.2003 · Cited by 117
van Zandvoort, M. A. M. J., de Grauw, C. J., Gerritsen, H. C., Broers, J. L. V., Egbrink, M. G. A. O., Ramaekers, F. C. S., & Slaaf, D. W. (2002) · Cytometry · doi:10.1002/cyto.10076 · Cited by 102
Luminescence Techniques in Chemical and Biochemical Analysis
Baeyens, W. R. G., Keukeleire, D. D., & Korkidis, K. (1990) · Ghent University Academic Bibliography (Ghent University) · Cited by 100
Kelbauskas, L., & Dietel, W. (2002) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2002)0760686ioapbt2.0.co2 · Cited by 80
Herman, B. (2020) · Garland Science eBooks · doi:10.1201/9781003077060-2 · Cited by 71
Multiwavelength TCSPC lifetime imaging
Becker, W. H., Bergmann, A., Biskup, C. U., et al. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.470679 · Cited by 60
Self-citationPicosecond fluorescence lifetime microscopy by TCSPC imaging
Becker, W. H., Bergmann, A., Koenig, K., & Tirlapur, U. K. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.424584 · Cited by 58
Self-citationMitchell, A. C., Wall, J. E., Murray, J. G., et al. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01029.x · Cited by 54
Measurement of nanosecond time‐resolved fluorescence with a directly gated interline CCD camera
Mitchell, A. C., Wall, J. E., Murray, J. G., et al. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01030.x · Cited by 51
Sensitive imaging of spectrally overlapping flourochromes using the LSM 510 META
Dickinson, M. E., Waters, C. W., Bearman, G. H., Wolleschensky, R., Tille, S., & Fraser, S. E. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.470686 · Cited by 21
Lifetime imaging with the Zeiss LSM-510
Becker, W. H., Bergmann, A., & Weiss, G. (2002) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.470706 · Cited by 17
Self-citationTime-gated autofluorescence microscopy of motile green microalga in an optical trap.
König, K., Boehme, S., Leclerc, N., & Ahuja, R. (1998) · PubMed · Cited by 15
Self-citation
Cited by
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
The Phasor Approach to Fluorescence Lifetime Imaging Analysis
Digman, M. A., Caiolfa, V. R., Zamai, M., & Gratton, E. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120154 · Cited by 1,145
Long-Lived Emissive Probes for Time-Resolved Photoluminescence Bioimaging and Biosensing
Zhang, K. Y., Yu, Q., Wei, H., Liu, S., Zhao, Q., & Huang, W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00425 · Cited by 923
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Self-citationImaging protein molecules using FRET and FLIM microscopy
Wallrabe, H., & Periasamy, A. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.002 · Cited by 724
Metadata
- Authors
- Becker, W., Bergmann, A., Hink, M. A., König, K., Benndorf, K., & Biskup, C.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 2003-12-10
- Volume
- 63
- Issue
- 1
- Pages
- 58-66
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W2090663204
- Cited by
- 513
- References
- 43
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.