The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Richardson–Lucy algorithm with total variation regularization for 3D confocal microscope deconvolution
Abstract
Confocal laser scanning microscopy is a powerful and popular technique for 3D imaging of biological specimens. Although confocal microscopy images are much sharper than standard epifluorescence ones, they are still degraded by residual out‐of‐focus light and by Poisson noise due to photon‐limited detection. Several deconvolution methods have been proposed to reduce these degradations, including the Richardson–Lucy iterative algorithm, which computes maximum likelihood estimation adapted to Poisson statistics. As this algorithm tends to amplify noise, regularization constraints based on some prior knowledge on the data have to be applied to stabilize the solution. Here, we propose to combine the Richardson–Lucy algorithm with a regularization constraint based on Total Variation, which suppresses unstable oscillations while preserving object edges. We show on simulated and real images that this constraint improves the deconvolution results as compared with the unregularized Richardson–Lucy algorithm, both visually and quantitatively. Microsc. Res. Tech. 69:260–266, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Introduction to Fourier Optics
Sutton, P. (1996) · Quantum and Semiclassical Optics: Journal of the European Optical Society Part B · doi:10.1088/1355-5111/8/5/014 · Cited by 4,934
Functions of Bounded Variation and Free Discontinuity Problems
Ambrosio, L., Fusco, N., & Pallara, D. (2000) · doi:10.1093/oso/9780198502456.001.0001 · Cited by 4,318
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866 · cited 2×
“Then one iteration of a multiplicative gradient type algorithm is given by (for more details see Appendix C of (Dey et al., 2004a)): CITER PLUTÔT (OU AUSSI) LUCY74 ET RICHARDSON72 ? ok+1(s) = {[ i(s) (ok ∗ h) (s) ] ∗ h(−s) } .ok(s) (8) which defines one iteration of the RL algorithm.”
MethodCsiszar, I. (1991) · The Annals of Statistics · doi:10.1214/aos/1176348385 · Cited by 790
Three-dimensional architecture of a polytene nucleus
Agard, D. A., & Sedat, J. W. (1983) · Nature · doi:10.1038/302676a0 · Cited by 446
Cited by
ImageJ2: ImageJ for the next generation of scientific image data
Rueden, C. T., Schindelin, J., Hiner, M. C., DeZonia, B. E., Walter, A. E., Arena, E. T., & Eliceiri, K. W. (2017) · BMC Bioinformatics · doi:10.1186/s12859-017-1934-z · Cited by 5,980
On the use of deep learning for computational imaging
Barbastathis, G., Ozcan, A., & Situ, G. (2019) · Optica · doi:10.1364/optica.6.000921 · Cited by 869
DeconvolutionLab2: An open-source software for deconvolution microscopy
Sage, D., Donati, L., Soulez, F., Fortun, D., Schmit, G., Seitz, A., Guiet, R., Vonesch, C., & Unser, M. (2017) · Methods · doi:10.1016/j.ymeth.2016.12.015 · Cited by 600
Applications, promises, and pitfalls of deep learning for fluorescence image reconstruction
Belthangady, C., & Royer, L. A. (2019) · Nature Methods · doi:10.1038/s41592-019-0458-z · Cited by 510
Chaudhry, A., Shi, R., & Luciani, D. S. (2020) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00457.2019 · Cited by 423
Metadata
- Authors
- Dey, N., Blanc‐Feraud, L., Zimmer, C., Roux, P., Kam, Z., Olivo‐Marin, J., & Zerubia, J.
- Venue
- Microscopy Research and Technique
- Publisher
- Wiley
- Published
- 2006-04
- Volume
- 69
- Issue
- 4
- Pages
- 260-266
- ISSN
- 1059-910X (ISSN-L)
- 1097-0029
- OpenAlex
- W2020111712
- Cited by
- 466
- References
- 17
- FWCI
- 14.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Richardson–Lucy algorithm with total variation regularization for 3D confocal microscope deconvolution. https://app.cochat.ai/papers/10.1002/jemt.20294
- The paper
- Dey, N., Blanc‐Feraud, L., Zimmer, C., Roux, P., Kam, Z., Olivo‐Marin, J., & Zerubia, J. (2006). Richardson–Lucy algorithm with total variation regularization for 3D confocal microscope deconvolution. Microscopy Research and Technique. https://doi.org/10.1002/jemt.20294
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.