A compendium of single extracellular vesicle flow cytometry
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Flow cytometry (FCM) offers a multiparametric technology capable of characterizing single extracellular vesicles (EVs). However, most flow cytometers are designed to detect cells, which are larger than EVs. Whereas cells exceed the background noise, signals originating from EVs partly overlap with the background noise, thereby making EVs more difficult to detect than cells. This technical mismatch together with complexity of EV‐containing fluids causes limitations and challenges with conducting, interpreting and reproducing EV FCM experiments. To address and overcome these challenges, researchers from the International Society for Extracellular Vesicles (ISEV), International Society for Advancement of Cytometry (ISAC), and the International Society on Thrombosis and Haemostasis (ISTH) joined forces and initiated the EV FCM working group. To improve the interpretation, reporting, and reproducibility of future EV FCM data, the EV FCM working group published an ISEV position manuscript outlining a framework of minimum information that should be reported about an FCM experiment on single EVs (MIFlowCyt‐EV). However, the framework contains limited background information. Therefore, the goal of this compendium is to provide the background information necessary to design and conduct reproducible EV FCM experiments. This compendium contains background information on EVs, the interaction between light and EVs, FCM hardware, experimental design and preanalytical procedures, sample preparation, assay controls, instrument data acquisition and calibration, EV characterization, and data reporting. Although this compendium focuses on EVs, many concepts and explanations could also be applied to FCM detection of other particles within the EV size range, such as bacteria, lipoprotein particles, milk fat globules, and viruses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Théry, C., Witwer, K. W., Aikawa, E., Alcaraz, M. J., Anderson, J. D., Andriantsitohaina, R., Antoniou, A., Arab, T., Archer, F., Atkin‐Smith, G. K., et al. (2018) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2018.1535750 · Cited by 11,099
Self-citationSaleh, B. E. A., & Teich, M. C. (1991) · doi:10.1002/0471213748 · Cited by 3,383
Quantum Dots and Their Multimodal Applications: A Review
Bera, D., Qian, L., Tseng, T.-K., & Holloway, P. H. (2010) · Materials · doi:10.3390/ma3042260 · Cited by 1,365
EV-TRACK: transparent reporting and centralizing knowledge in extracellular vesicle research
EV-TRACK Consortium, Van Deun, J., Mestdagh, P., Agostinis, P., Akay, Ö., Anand, S., Anckaert, J., Martinez, Z. A., Baetens, T., Beghein, E., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4185 · Cited by 1,284
Self-citationCell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887
Tian, Y., Gong, M., Hu, Y., Liu, H., Zhang, W., Zhang, M., Hu, X., Aubert, D., Zhu, S., Wu, L., et al. (2020) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2019.1697028 · Cited by 643
Self-citationCloutier, N., Tan, S., Boudreau, L. H., Cramb, C., Subbaiah, R., Lahey, L., Albert, A., Shnayder, R., Gobezie, R., Nigrovic, P. A., et al. (2013) · EMBO Molecular Medicine · doi:10.1002/emmm.201201846 · Cited by 254
Semiconducting polymer dots with bright narrow-band emission at 800 nm for biological applications
Chen, D., Wu, I.-C., Liu, Z., Tang, Y., Chen, H., Yu, J., Wu, C., & Chiu, D. T. (2017) · Chemical Science · doi:10.1039/c7sc00441a · Cited by 78
Cited by
Welsh, J. A., Goberdhan, D. C. I., O'Driscoll, L., Buzas, E. I., Blenkiron, C., Bussolati, B., Cai, H., Di Vizio, D., Driedonks, T. A. P., Erdbrügger, U., et al. (2024) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12404 · Cited by 4,663
Self-citationEmergence of Extracellular Vesicles as “Liquid Biopsy” for Neurological Disorders: Boom or Bust
Kumar, A., Nader, M. A., & Deep, G. (2024) · Pharmacological Reviews · doi:10.1124/pharmrev.122.000788 · Cited by 79
Extracellular vesicles: New horizons in neurodegeneration
Chen, J., Tian, C., Xiong, X., Yang, Y., & Zhang, J. (2025) · eBioMedicine · doi:10.1016/j.ebiom.2025.105605 · Cited by 53
Amyloid-β oligomers increase the binding and internalization of tau oligomers in human synapses
Kadamangudi, S., Marcatti, M., Zhang, W.-R., Fracassi, A., Kayed, R., Limon, A., & Taglialatela, G. (2024) · Acta Neuropathologica · doi:10.1007/s00401-024-02839-2 · Cited by 25
Metadata
- Authors
- Welsh, J. A., Arkesteijn, G. J. A., Bremer, M., Cimorelli, M., Dignat‐George, F., Giebel, B., Görgens, A., Hendrix, A., Kuiper, M., Lacroix, R., Lannigan, J., van Leeuwen, T. G., Lozano‐Andrés, E., Rao, S., Robert, S., de Rond, L., Tang, V. A., Tertel, T., Yan, X., Wauben, M. H. M., Nolan, J. P., Jones, J. C., Nieuwland, R., & van der Pol, E.
- Venue
- Journal of Extracellular Vesicles
- Publisher
- Wiley
- Published
- 2023-02
- Volume
- 12
- Issue
- 2
- Pages
- e12299-e12299
- ISSN
- 2001-3078 (ISSN-L)
- OpenAlex
- W4319825886
- Cited by
- 251
- References
- 9
- FWCI
- 18.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.