Society of hospital medicine glycemic control task force summary: Practical recommendations for assessing the impact of glycemic control efforts
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
5 University of California San Diego, Division of Hospital Medicine, Department of Medicine, San Diego, California D ata collection, analysis, and presentation are key to the success of any hospital glycemic control initiative. Such efforts enable the management team to track improvements in processes and outcomes, make necessary changes to their quality improvement efforts, justify the provision of necessary time and resources, and share their results with others. Reliable metrics for assessing glycemic control and frequency of hypoglycemia are essential to accomplish these tasks and to assess whether interventions result in more benefit than harm. Hypoglycemia metrics must be especially convincing because fear of hypoglycemia remains a major source of clinical inertia, impeding efforts to improve glucose control. Currently, there are no official standards or guidelines for formulating metrics on the quality of inpatient glycemic control. This creates several problems. First, different metrics vary in their biases and in their responsiveness to change. Thus, use of a poor metric could lead to either a falsely positive or falsely negative impression that a quality improvement intervention is in fact improving glycemic control. Second, the proliferation of different measures and analytical plans in the research and quality improvement literature make it very difficult for hospitals to compare baseline performance, determine need for improvement, and understand which interventionsmay bemost effective. A related article in this supplement provides the rationale for improved inpatient glycemic control. That article argues that the current state of inpatient glycemic control, with the frequent occurrence of severe hyperglycemia and irrational insulin ordering, cannot be considered acceptable, especially given the large body of data (albeit largely observational) linking hyperglycemia to negative patient outcomes. However, regardless of whether one is an advocate or skeptic of tighter glucose control in the intensive care unit (ICU) and especially the non-ICU setting, there is no question that standardized, valid, and reliable metrics are needed to compare efforts to improve glycemic control, better understand whether such control actually improves patient care, and closely monitor patient safety. This article provides a summary of practical suggestions to assess glycemic control, insulin use patterns, and safety (hypoglycemia and severe hyperglycemia). In particular, we discuss the pros and cons of various measurement choices. We conclude with a tiered summary of recommendations for practical metrics No honoraria were paid to any authors for time and expertise spent on the writing of this article.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kosiborod, M., Inzucchi, S. E., Krumholz, H. M., Xiao, L., Jones, P. G., Fiske, S., Masoudi, F. A., Marso, S. P., & Spertus, J. A. (2008) · Circulation · doi:10.1161/circulationaha.107.740498 · Cited by 385
Self-citation
Cited by
Umpierrez, G. E., Hellman, R., Korytkowski, M. T., Kosiborod, M., Maynard, G. A., Montori, V. M., Seley, J. J., & Van den Berghe, G. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-2098 · Cited by 1,126
Self-citationJacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Pasquel, F. J., Gianchandani, R., Rubin, D. J., Dungan, K. M., Anzola, I., Gomez, P. C., Peng, L., Hodish, I., Bodnar, T., Wesorick, D., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30402-8 · Cited by 168
Umpierrez, G. E., Gianchandani, R., Smiley, D., Jacobs, S., Wesorick, D. H., Newton, C., Farrokhi, F., Peng, L., Reyes, D., Lathkar-Pradhan, S., et al. (2013) · Diabetes Care · doi:10.2337/dc13-0277 · Cited by 166
Hyperglycemia during the immediate period after kidney transplantation
Chakkera, H. A., Weil, E. J., Castro, J., Heilman, R. L., Reddy, K. S., Mazur, M. J., Hamawi, K., Mulligan, D. C., Moss, A. A., Mekeel, K. L., et al. (2009) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.05471008 · Cited by 124
Perioperative management of hyperglycemia and diabetes in cardiac surgery patients
Galindo, R. J., Fayfman, M., & Umpierrez, G. E. (2018) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2017.10.005 · Cited by 95
“Clinical guidelines on inpatient management of hyperglycemia recommend the use of IV CII in critically ill and in cardiac surgery patients with and without a history of diabetes.(37,39,60,70,71) Several cohort and randomized controlled trials in cardiac sur-”
MethodBueno, E., Benitez, A., Rufinelli, J., Figueredo, R., Alsina, S., Ojeda, A., Samudio, S., Cáceres, M., Argüello, R., Romero, F., et al. (2015) · Endocrine Practice · doi:10.4158/ep15675.or · Cited by 56
Impact of a hypoglycemia reduction bundle and a systems approach to inpatient glycemic management
Maynard, G., Kulasa, K., Ramos, P., Childers, D., Clay, B., Sebasky, M., Fink, E., Field, A., Renvall, M., Juang, P. S., et al. (2015) · Endocrine Practice · doi:10.4158/ep14367.or · Cited by 52
Self-citationAng, L., Lin, Y. K., Schroeder, L. F., Huang, Y., DeGeorge, C. A., Arnold, P., Akanbi, F., Knotts, S., DuBois, E., Desbrough, N., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241241005 · Cited by 11
Metadata
- Authors
- Schnipper, J. L., Magee, M., Larsen, K., Inzucchi, S. E., & Maynard, G.
- Venue
- Journal of Hospital Medicine
- Publisher
- Wiley
- Published
- 2008-10-24
- Volume
- 3
- Issue
- S5
- Pages
- 66-75
- ISSN
- 1553-5592 (ISSN-L)
- 1553-5606
- OpenAlex
- W1974174195
- Cited by
- 74
- References
- 1
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.