The DOI matches its Crossref record; 115 of the 115 references it cites were found in a registry or an index.
A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: applications of acoustic physics to the analysis of biomolecular interactions
Abstract
The widespread exploitation of biosensors in the analysis of molecular recognition has its origins in the mid‐1990s following the release of commercial systems based on surface plasmon resonance (SPR). More recently, platforms based on piezoelectric acoustic sensors (principally ‘bulk acoustic wave’ (BAW), ‘thickness shear mode’ (TSM) sensors or ‘quartz crystal microbalances’ (QCM)), have been released that are driving the publication of a large number of papers analysing binding specificities, affinities, kinetics and conformational changes associated with a molecular recognition event. This article highlights salient theoretical and practical aspects of the technologies that underpin acoustic analysis, then reviews exemplary papers in key application areas involving small molecular weight ligands, carbohydrates, proteins, nucleic acids, viruses, bacteria, cells and lipidic and polymeric interfaces. Key differentiators between optical and acoustic sensing modalities are also reviewed. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
The use of quarts oscillators for weighing thin layers and for microweighing
Sauerbrey, G., & Sauerbrey, G. (1959) · Medical Entomology and Zoology · Cited by 4,456
Annexins: From Structure to Function
Gerke, V., & Moss, S. E. (2002) · Physiological Reviews · doi:10.1152/physrev.00030.2001 · Cited by 2,029
Rodahl, M., Höök, F., Krozer, A., Brzezinski, P., & Kasemo, B. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145396 · Cited by 1,296
Höök, F., Kasemo, B., Nylander, T., Fant, C., Sott, K., & Elwing, H. (2001) · Analytical Chemistry · doi:10.1021/ac0106501 · Cited by 1,162
Marx, K. A. (2003) · Biomacromolecules · doi:10.1021/bm020116i · Cited by 1,143
Optical biosensors in drug discovery
Cooper, M. A. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd838 · Cited by 1,015
Self-citationProbing BSA Binding to Citrate-Coated Gold Nanoparticles and Surfaces
Brewer, S. H., Glomm, W. R., Johnson, M. C., Knag, M. K., & Franzen, S. (2005) · Langmuir · doi:10.1021/la050588t · Cited by 892
The Density and Refractive Index of Adsorbing Protein Layers
Vörös, J. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.030072 · Cited by 752
Piezoelectric Mass-Sensing Devices as Biosensors—An Alternative to Optical Biosensors?
Janshoff, A., Galla, H.-J., & Steinem, C. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20001117)39:22<4004::aid-anie4004>3.0.co;2-2 · Cited by 712
Höök, F., Vörös, J., Rodahl, M., Kurrat, R., Böni, P., Ramsden, J. J., Textor, M., Spencer, N. D., Tengvall, P., Gold, J., et al. (2002) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(01)00236-3 · Cited by 671
Pathways of Lipid Vesicle Deposition on Solid Surfaces: A Combined QCM-D and AFM Study
Richter, R., Mukhopadhyay, A., & Brisson, A. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74722-5 · Cited by 670
Reimhult, E., Höök, F., & Kasemo, B. (2003) · Langmuir · doi:10.1021/la0263920 · Cited by 641
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
Richter, R. P., & Brisson, A. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.053728 · Cited by 472
Richert, L., Boulmedais, F., Lavalle, P., Mutterer, J., Ferreux, E., Decher, G., Schaaf, P., Voegel, J.-C., & Picart, C. (2004) · Biomacromolecules · doi:10.1021/bm0342281 · Cited by 437
Surface sensing and adhesion of Escherichia coli controlled by the Cpx-signaling pathway
Otto, K., & Silhavy, T. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.042521699 · Cited by 401
‘Missing mass’ effect in biosensor's QCM applications
Voinova, M. V., Jonson, M., & Kasemo, B. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00050-7 · Cited by 376
Detection of single-base DNA mutations by enzyme-amplified electronic transduction
Patolsky, F., Lichtenstein, A., & Willner, I. (2001) · Nature Biotechnology · doi:10.1038/85704 · Cited by 368
Frequency shifts of piezoelectric quartz crystals immersed in organic liquids
NOMURA, T., & OKUHARA, M. (1982) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95290-0 · Cited by 347
Protein Adsorption on Supported Phospholipid Bilayers
Glasmästar, K., Larsson, C., Höök, F., & Kasemo, B. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2001.8060 · Cited by 303
Vesicle adsorption on SiO2 and TiO2: Dependence on vesicle size
Reimhult, E., Höök, F., & Kasemo, B. (2002) · The Journal of Chemical Physics · doi:10.1063/1.1515320 · Cited by 273
Higher-throughput, label-free, real-time molecular interaction analysis
Rich, R. L., & Myszka, D. G. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2006.10.040 · Cited by 264
Implementing surface plasmon resonance biosensors in drug discovery
Myszka, D. G., & Rich, R. L. (2000) · Pharmaceutical Science & Technology Today · doi:10.1016/s1461-5347(00)00288-1 · Cited by 236
Doxorubicin Uptake and Release from Microgel Thin Films
Serpe, M. J., Yarmey, K. A., Nolan, C. M., & Lyon, L. A. (2005) · Biomacromolecules · doi:10.1021/bm049455x · Cited by 222
Höök, F., Ray, A., Nordén, B., & Kasemo, B. (2001) · Langmuir · doi:10.1021/la0107704 · Cited by 217
Penetration of Rifampin through Staphylococcus epidermidis Biofilms
Zheng, Z., & Stewart, P. S. (2002) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.46.3.900-903.2002 · Cited by 206
Advances in membrane receptor screening and analysis
Cooper, M. A. (2004) · Journal of Molecular Recognition · doi:10.1002/jmr.675 · Cited by 198
Self-citationDetection of influenza virus: traditional approaches and development of biosensors
Amano, Y., & Cheng, Q. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2927-0 · Cited by 185
Su, X.-L., & Li, Y. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.01.021 · Cited by 182
Expression of Functional Recombinant Mussel Adhesive Protein Mgfp-5 in Escherichia coli
Hwang, D. S., Yoo, H. J., Jun, J. H., Moon, W. K., & Cha, H. J. (2004) · Applied and Environmental Microbiology · doi:10.1128/aem.70.6.3352-3359.2004 · Cited by 180
Emerging biomedical sensing technologies and their applications
Cote, G. L., Lec, R. M., & Pishko, M. V. (2003) · IEEE Sensors Journal · doi:10.1109/jsen.2003.814656 · Cited by 180
Serizawa, T., Yamaguchi, M., & Akashi, M. (2002) · Biomacromolecules · doi:10.1021/bm0200027 · Cited by 176
Zhou, X. C., Huang, L. Q., & Li, S. F. Y. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00136-6 · Cited by 174
Cholesterol biosensors prepared by layer-by-layer technique
Ram, M. K., Bertoncello, P., Ding, H., Paddeu, S., & Nicolini, C. A. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00208-1 · Cited by 166
Weizmann, Y., Patolsky, F., & Willner, I. (2001) · The Analyst · doi:10.1039/b106613g · Cited by 166
C3 Adsorbed to a Polymer Surface Can Form an Initiating Alternative Pathway Convertase
Andersson, J., Ekdahl, K. N., Larsson, R. L., Nilsson, U., & Nilsson, B. (2002) · The Journal of Immunology · doi:10.4049/jimmunol.168.11.5786 · Cited by 148
Alfonta, L., Willner, I., Throckmorton, D. J., & Singh, A. K. (2001) · Analytical Chemistry · doi:10.1021/ac010542e · Cited by 144
Determination of albumin concentration by MIP-QCM sensor
Lin, T., Hu, C.-H., & Chou, T. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.028 · Cited by 133
Willner, I. (2002) · Talanta · doi:10.1016/s0039-9140(01)00658-0 · Cited by 131
Molecular-Imprinted, Polymer-Coated Quartz Crystal Microbalances for the Detection of Terpenes
Percival, C. J., Stanley, S., Galle, M., et al. (2001) · Analytical Chemistry · doi:10.1021/ac0155198 · Cited by 127
Detection of two orchid viruses using quartz crystal microbalance (QCM) immunosensors
Eun, A. J.-C., Huang, L., Chew, F. T., Li, S. F. Y., & Wong, S. (2002) · Journal of Virological Methods · doi:10.1016/s0166-0934(01)00382-2 · Cited by 121
Survey of the year 2005 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2006) · Journal of Molecular Recognition · doi:10.1002/jmr.808 · Cited by 120
Abad, J. M., Vélez, M., Santamaría, C., et al. (2002) · Journal of the American Chemical Society · doi:10.1021/ja026658p · Cited by 119
Granéli, A., Rydström, J., Kasemo, B., & Höök, F. (2003) · Langmuir · doi:10.1021/la026231w · Cited by 115
Cell adhesion on supported lipid bilayers
Andersson, A., Glasmästar, K., Sutherland, D. S., Lidberg, U., & Kasemo, B. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10442 · Cited by 114
Dupont‐Filliard, A., Billon, M., Livache, T., & Guillerez, S. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.03.072 · Cited by 112
The Quartz Crystal Microbalance as a Novel Means to Study Cell-Substrate Interactions In Situ
Wegener, J., Janshoff, A., & Steinem, C. (2001) · Cell Biochemistry and Biophysics · doi:10.1385/cbb:34:1:121 · Cited by 111
Seantier, B., Breffa, C., Félix, O., & Decher, G. (2003) · Nano Letters · doi:10.1021/nl034590l · Cited by 110
Sensitivity, noise, and resolution in QCM sensors in liquid media
Rodríguez-Pardo, L., Rodriguez, J. F., Gabrielli, C., Perrot, H., & Brendel, R. (2005) · IEEE Sensors Journal · doi:10.1109/jsen.2005.859257 · Cited by 107
Hama, H., Saito, A., Takeda, T., Tanuma, A., Xie, Y., Sato, K., Kazama, J. J., & Gejyo, F. (2004) · Endocrinology · doi:10.1210/en.2004-0074 · Cited by 104
Lu, Q.-W., Morimoto, S., Harada, K., Du, C., Takahashi‐Yanaga, F., Miwa, Y., Sasaguri, T., & Ohtsuki, I. (2003) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2003.09.003 · Cited by 101
Ignatova, M., Voccia, S., Gilbert, B., Markova, N., Mercuri, P. S., Galleni, M., Sciannamea, V., Lenoir, S., Cossement, D., Gouttebaron, R., et al. (2004) · Langmuir · doi:10.1021/la048347t · Cited by 95
Piezoelectric biosensors: Strategies for coupling nucleic acids to piezoelectric devices
Tombelli, S., Minunni, M., & Mascini, M. (2005) · Methods · doi:10.1016/j.ymeth.2005.05.005 · Cited by 91
Otto, K., & Hermansson, M. (2003) · Journal of Bacteriology · doi:10.1128/jb.186.1.226-234.2004 · Cited by 85
Lojou, É., & Bianco, P. (2004) · Langmuir · doi:10.1021/la030286w · Cited by 85
Patolsky, F., Lichtenstein, A., & Willner, I. (2003) · Chemistry - A European Journal · doi:10.1002/chem.200390131 · Cited by 83
Marxer, C. G., Coen, M. C., Greber, T., Greber, U. F., & Schlapbach, L. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2080-1 · Cited by 82
Investigation of highly sensitive piezoelectric immunosensors for 2,4-dichlorophenoxyacetic acid
Halámek, J., Hepel, M., & Skládal, P. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00132-4 · Cited by 79
Model films of cellulose ID – improved preparation method and characterization of the cellulose film
Fält, S., Wågberg, L., Vesterlind, E.-L., & Larsson, P. T. (2004) · Cellulose · doi:10.1023/b:cell.0000025403.23775.75 · Cited by 78
Cans, A.-S. U., Höök, F., Shupliakov, O., Ewing, A. G., Eriksson, P. S., Brodin, L., & Orwar, O. (2001) · Analytical Chemistry · doi:10.1021/ac010777q · Cited by 76
Marx, K. A., Zhou, T., Montrone, A., McIntosh, D., & Braunhut, S. J. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.05.013 · Cited by 75
About the Role of Water in Surface-Grafted Poly(ethylene glycol) Layers
Heuberger, M. P., Drobek, T., & Vörös, J. (2004) · Langmuir · doi:10.1021/la048384k · Cited by 75
Marx, K. A., Zhou, T., Warren, M. R., & Braunhut, S. J. (2003) · Biotechnology Progress · doi:10.1021/bp0201096 · Cited by 75
Frequency dependent and surface characterization of DNA immobilization and hybridization
Hang, T. C., & Guiseppi‐Elie, A. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.12.014 · Cited by 73
Tominaga, M., Ohira, A., Yamaguchi, Y., & Kunitake, M. (2004) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2003.11.056 · Cited by 71
Microbalance-DNA probe method for the detection of specific bacteria in water
Mo, X.-T., Zhou, Y., Lei, H., & Deng, L. (2002) · Enzyme and Microbial Technology · doi:10.1016/s0141-0229(01)00484-7 · Cited by 68
Kinetics and Thermodynamics of Annexin A1 Binding to Solid-Supported Membranes: A QCM Study
Kastl, K., Ross, M., Gerke, V., & Steinem, C. (2002) · Biochemistry · doi:10.1021/bi025951z · Cited by 67
Su, X., & Zhang, J. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.01.020 · Cited by 66
Stålgren, J. J. R., Eriksson, J. C., & Boschkova, K. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8482 · Cited by 65
Gurdak, E., Dupont‐Gillain, C. C., Booth, J., et al. (2005) · Langmuir · doi:10.1021/la051227g · Cited by 65
Galeska, I., Hickey, T., Moussy, F. G., Kreutzer, D. L., & Papadimitrakopoulos, F. (2001) · Biomacromolecules · doi:10.1021/bm010112y · Cited by 62
Two-step sequential reaction catalyzed by layer-by-layer assembled urease and arginase multilayers
Disawal, S., Qiu, J., Elmore, B. B., & LVOV, Y. M. (2003) · Colloids and Surfaces B Biointerfaces · doi:10.1016/s0927-7765(03)00154-1 · Cited by 62
Notley, S. M., Biggs, S., Craig, V. S. J., & Wågberg, L. (2004) · Physical Chemistry Chemical Physics · doi:10.1039/b401376j · Cited by 60
Surfaces engineering of polymeric films for biomedical applications
Rossini, P., Colpo, P., Ceccone, G., Jandt, K. D., & Rossi, F. (2003) · Materials Science and Engineering C · doi:10.1016/s0928-4931(02)00286-2 · Cited by 57
Fibronectin Displacement at Polymer Surfaces
Renner, L. D., Pompe, W., Salchert, K., & Werner, C. (2005) · Langmuir · doi:10.1021/la046801n · Cited by 57
Michalzik, M., Wendler, J., Rabe, J., Büttgenbach, S., & Bilitewski, U. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.07.012 · Cited by 57
Pavlov, V. V., Willner, I., Dishon, A., & Kotler, M. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.06.020 · Cited by 55
Miura, Y., Sasao, Y., Dohi, H., Nishida, Y., & Kobayashi, K. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00318-4 · Cited by 55
Direct Quantification of Analyte Concentration by Resonant Acoustic Profiling
Godber, B., Thompson, K. S. J., Rehak, M., Uludağ, Y., Kelling, S., Sleptsov, A., Frogley, M. D., Wiehler, K., Whalen, C., & Cooper, M. A. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.053249 · Cited by 55
Self-citationFibrin Proliferation at Model Surfaces: Influence of Surface Properties
Evans-Nguyen, K. M., & Schoenfisch, M. H. (2005) · Langmuir · doi:10.1021/la047303h · Cited by 54
Paananen, A., Österberg, M., Rutland, M. W., Tammelin, T., Saarinen, T., Tappura, K., & Stenius, P. J. (2003) · ACS symposium series · doi:10.1021/bk-2004-0864.ch018 · Cited by 53
Chou, S.-F., Hsu, W.-L., Hwang, J., & Chen, C. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01466-0 · Cited by 50
Liu, Y., Yu, X., Zhao, R., Shangguan, D., Bo, Z., & Liu, G. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00090-3 · Cited by 50
Su, X., Zong, Y., Richter, R. P., & Knoll, W. (2005) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2005.01.089 · Cited by 49
Rapid detection of bacterial spores using a quartz crystal microbalance (QCM) immunoassay
Lee, S., Stubbs, D. D., Cairney, J., et al. (2005) · IEEE Sensors Journal · doi:10.1109/jsen.2005.848124 · Cited by 49
pH-Dependent Behavior of Surface-immobilized Artificial Leucine Zipper Proteins
Stevens, M. M., Allen, S., Sakata, J. K., Davies, M. C., Roberts, C. J., Tendler, S. J. B., Tirrell, D. A., & Williams, P. M. (2004) · Langmuir · doi:10.1021/la030440e · Cited by 48
Fant, C., Elwing, H. B., & Höök, F. (2002) · Biomacromolecules · doi:10.1021/bm025506j · Cited by 48
Reversible oligonucleotide immobilisation based on biotinylated polypyrrole film
Dupont‐Filliard, A., Roget, A., Livache, T., et al. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01339-3 · Cited by 48
An acoustic wave sensor incorporated with a microfluidic chip for analyzing muscle cell contraction
Li, P. C. H., Wang, W., & Parameswaran, M. A. (2003) · The Analyst · doi:10.1039/b209030a · Cited by 47
Fujisaki, H., & Hattori, S. (2002) · Experimental Cell Research · doi:10.1006/excr.2002.5639 · Cited by 46
Fluid Biomembranes Supported on Nanoporous Aerogel/Xerogel Substrates
Weng, K. C., Stålgren, J. J. R., Duval, D. J., Risbud, S. H., & Frank, C. W. (2004) · Langmuir · doi:10.1021/la049940d · Cited by 43
Yamashita, K., Aoyagi, Y., Abe, H., & Doi, Y. (2000) · Biomacromolecules · doi:10.1021/bm0000844 · Cited by 40
Schenkman, J. B., Jansson, I., LVOV, Y. M., Rusling, J. F., Boussaad, S., & Tao, N. J. (2001) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.2000.2140 · Cited by 40
Rapid detection of Salmonella enteritidis by piezoelectric immunosensor
Si, S., Li, X., Fung, Y., et al. (2001) · Microchemical Journal · doi:10.1016/s0026-265x(00)00167-3 · Cited by 38
Adhesion of liposomes: a quartz crystal microbalance study
Lüthgens, E., Herrig, A., Kastl, K., Steinem, C., Reiß, B., Wegener, J., Pignataro, B., & Janshoff, A. (2003) · Measurement Science and Technology · doi:10.1088/0957-0233/14/11/003 · Cited by 38
Ross, M., Gerke, V., & Steinem, C. (2003) · Biochemistry · doi:10.1021/bi027069z · Cited by 34
Ha, T. H., Kim, S., Lim, G., & Kim, K. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.02.027 · Cited by 33
Ng, S., Sun, T., & Chan, H. S. O. (2002) · Tetrahedron Letters · doi:10.1016/s0040-4039(02)00267-8 · Cited by 31
Determination of 4-aminophenol using the quartz crystal microbalance sensor
Karousos, N. G., & Reddy, S. M. (2002) · The Analyst · doi:10.1039/b111301c · Cited by 31
Circulating level of α2-macroglobulin–β2-microglobulin complex in hemodialysis patients
Motomiya, Y., Ando, Y., Haraoka, K., Sun, X., Iwamoto, H., Uchimura, T., & Maruyama, I. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00315.x · Cited by 31
Application of the quartz crystal microbalance for determination of phenol in solution
Mirmohseni, A., & Oladegaragoze, A. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.08.011 · Cited by 30
Kinetic characterization of TAR RNA–Tat peptide and neomycin interactions by acoustic wave biosensor
Tassew, N. G., & Thompson, M. E. (2003) · Biophysical Chemistry · doi:10.1016/s0301-4622(03)00155-8 · Cited by 30
Fietzek, C., Hermle, T., Rosenstiel, W., & Schurig, V. (2001) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160100899 · Cited by 28
Camptothecin binds to a synthetic peptide identified by a T7 phage display screen
Takakusagi, Y., Kobayashi, S. S., & Sugawara, F. (2005) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2005.07.017 · Cited by 24
Rapid three-dimensional biointerfaces for real-time immunoassay using hIL-18BPa as a model antigen
Carrigan, S. D., Scott, G. M., & Tabrizian, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.089 · Cited by 22
Liu, S., Li, J., & Jiang, L. (2004) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2004.10.059 · Cited by 21
Park, M.-K., Youk, J. H., Pispas, S., Hadjichristidis, N., & Advíncula, R. C. (2002) · Langmuir · doi:10.1021/la025913g · Cited by 21
QCM–FIA with PGMA coating for dynamic interaction study of heparin and antithrombin III
Zhang, H., Zhao, R., Chen, Z., Shangguan, D., & Liu, G. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.08.041 · Cited by 20
Stine, R., Pishko, M. V., Hampton, J. R., Dameron, A. A., & Weiss, P. S. (2005) · Langmuir · doi:10.1021/la051150w · Cited by 20
A Novel Tool for Detecting Amyloid Deposits in Systemic Amyloidosis In Vitro and In Vivo
Ando, Y., Haraoka, K., Terazaki, H., et al. (2003) · Laboratory Investigation · doi:10.1097/01.lab.0000101701.87433.c5 · Cited by 20
45- and 70-Base DNA supramolecular polymerizations on quartz crystal microbalance biosensor
Lazerges, M., Perrot, H., Rabehagasoa, N., Antoine, E., & Compère, C. (2005) · Chemical Communications · doi:10.1039/b506305a · Cited by 13
Response of a Thickness-Shear-Mode Acoustic Wave Sensor to the Adsorption of Lipoprotein Particles
Snellings, S. L., Fuller, J., & Paul, D. W. (2001) · Langmuir · doi:10.1021/la0015157 · Cited by 9
Cited by
Critical review on biofilm methods
Azeredo, J., Azevedo, N. F., Briandet, R., Cerca, N., Coenye, T., Costa, A. R., Desvaux, M., Di Bonaventura, G., Hébraud, M., Jaglic, Z., et al. (2017) · Critical Reviews in Microbiology · doi:10.1080/1040841x.2016.1208146 · Cited by 1,045
Cho, N.-J., Frank, C. W., Kasemo, B., & Höök, F. (2010) · Nature Protocols · doi:10.1038/nprot.2010.65 · Cited by 542
Whitcombe, M. J., Kirsch, N., & Nicholls, I. A. (2014) · Journal of Molecular Recognition · doi:10.1002/jmr.2347 · Cited by 445
Biophysics in drug discovery: impact, challenges and opportunities
Renaud, J.-P., Chung, C.-W., Danielson, U. H., Egner, U., Hennig, M., Hubbard, R. E., & Nar, H. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.123 · Cited by 382
Towards on-site pathogen detection using antibody-based sensors
Skottrup, P. D., Nicolaisen, M., & Justesen, A. F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.06.045 · Cited by 352
Metadata
- Authors
- Cooper, M. A., & Singleton, V. T.
- Venue
- Journal of Molecular Recognition
- Publisher
- Wiley
- Published
- 2007-05
- Volume
- 20
- Issue
- 3
- Pages
- 154-184
- ISSN
- 0952-3499 (ISSN-L)
- 1099-1352
- OpenAlex
- W2143727927
- Cited by
- 370
- References
- 115
- FWCI
- 22.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.