Contrast‐enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization

Open access
Yuan, Chun, Kerwin, William S., Ferguson, Marina S., Polissar, Nayak, Zhang, Shaoxiong, Cai, Jianming, Hatsukami, Thomas S.·2002·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To determine if a gadolinium‐based contrast agent provides additional information for characterization of human plaque tissues, particularly neovasculature. Although high‐resolution magnetic resonance imaging (MRI) has been used to identify plaque constituents in advanced atherosclerosis, some constituents, such as neovascularized tissue, defy detection. Materials and Methods: Non‐contrast‐enhanced carotid artery images from 18 patients scheduled for carotid endarterectomy and two normal volunteers were used to identify regions of fibrous tissue, necrotic core, or calcification, using established criteria. Then, the percent change in T1‐weighted images after contrast enhancement was calculated for each region. Results: There were statistically significant differences in mean intensity change between tissues, with the largest increase for fibrous tissue (79.5%) and the smallest for necrotic core (28.6%). Additionally, histological analysis showed that a subset of fibrous regions rich in plaque neovascularization could be identified using a threshold of 80% enhancement (sensitivity = 76%, specificity = 79%). Conclusion: The ability of contrast‐enhanced MRI to identify neovascularization and potentially improve differentiation of necrotic core from fibrous tissue further establishes MRI as a viable tool for in vivo study of atherosclerotic plaque. J. Magn. Reson. Imaging 2002;15:62–67. Published 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.10030

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 422

Metadata

Authors
Yuan, C., Kerwin, W. S., Ferguson, M. S., Polissar, N., Zhang, S., Cai, J., & Hatsukami, T. S.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2002-01
Volume
15
Issue
1
Pages
62-67
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2115862124
Cited by
422
References
0
FWCI
17.47
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Contrast‐enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization. https://app.cochat.ai/papers/10.1002/jmri.10030
The paper
Yuan, C., Kerwin, W. S., Ferguson, M. S., Polissar, N., Zhang, S., Cai, J., & Hatsukami, T. S. (2002). Contrast‐enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10030

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.