The DOI matches its Crossref record.
Contrast‐enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization
Open accessAbstract
Purpose: To determine if a gadolinium‐based contrast agent provides additional information for characterization of human plaque tissues, particularly neovasculature. Although high‐resolution magnetic resonance imaging (MRI) has been used to identify plaque constituents in advanced atherosclerosis, some constituents, such as neovascularized tissue, defy detection. Materials and Methods: Non‐contrast‐enhanced carotid artery images from 18 patients scheduled for carotid endarterectomy and two normal volunteers were used to identify regions of fibrous tissue, necrotic core, or calcification, using established criteria. Then, the percent change in T1‐weighted images after contrast enhancement was calculated for each region. Results: There were statistically significant differences in mean intensity change between tissues, with the largest increase for fibrous tissue (79.5%) and the smallest for necrotic core (28.6%). Additionally, histological analysis showed that a subset of fibrous regions rich in plaque neovascularization could be identified using a threshold of 80% enhancement (sensitivity = 76%, specificity = 79%). Conclusion: The ability of contrast‐enhanced MRI to identify neovascularization and potentially improve differentiation of necrotic core from fibrous tissue further establishes MRI as a viable tool for in vivo study of atherosclerotic plaque. J. Magn. Reson. Imaging 2002;15:62–67. Published 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Winter, P. M., Morawski, A. M., Caruthers, S. D., Fuhrhop, R. W., Zhang, H., Williams, T. A., Allen, J. S., Lacy, E. K., Robertson, J. D., Lanza, G. M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093185.16083.95 · Cited by 696
Quantitative Evaluation of Carotid Plaque Composition by In Vivo MRI
Saam, T., Ferguson, M. S., Yarnykh, V. L., Takaya, N., Xu, D., Polissar, N. L., Hatsukami, T. S., & Yuan, C. (2005) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000149867.61851.31 · Cited by 616
Self-citationSaam, T., Hatsukami, T. S., Takaya, N., Chu, B., Underhill, H., Kerwin, W. S., Cai, J., Ferguson, M. S., & Yuan, C. (2007) · Radiology · doi:10.1148/radiol.2441051769 · Cited by 331
Self-citationSirol, M., Itskovich, V. V., Mani, V., Aguinaldo, J. G. S., Fallon, J. T., Misselwitz, B., Weinmann, H.-J., Fuster, V., Toussaint, J.-F., & Fayad, Z. A. (2004) · Circulation · doi:10.1161/01.cir.0000129310.17277.e7 · Cited by 192
Automatic segmentation of the right ventricle from cardiac MRI using a learning‐based approach
Avendi, M. R., Kheradvar, A., & Jafarkhani, H. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26631 · Cited by 135
Metadata
- Authors
- Yuan, C., Kerwin, W. S., Ferguson, M. S., Polissar, N., Zhang, S., Cai, J., & Hatsukami, T. S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 15
- Issue
- 1
- Pages
- 62-67
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2115862124
- Cited by
- 422
- References
- 0
- FWCI
- 17.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contrast‐enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization. https://app.cochat.ai/papers/10.1002/jmri.10030
- The paper
- Yuan, C., Kerwin, W. S., Ferguson, M. S., Polissar, N., Zhang, S., Cai, J., & Hatsukami, T. S. (2002). Contrast‐enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.