Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging
Open accessAbstract
Purpose: To evaluate reproducibility of total cerebral blood flow (CBF) measurements with phase contrast magnetic resonance imaging (pcMRI). Materials and Methods: We repeated total CBF measurements in 15 healthy volunteers with and without cardiac triggering, and with and without repositioning. In eight volunteers measurements were performed at two different occasions. In addition, measurement of flow in a phantom was performed to validate MR measurements. Results: A difference of 40.4 ml/minute was found between CBF measurements performed with and without triggering (P < 0.05). For repeated triggered measurements, the coefficient of variation (CV) was 7.1%, and for nontriggered measurements 10.3%. For repeated measurements with repositioning, the CV was 7.1% with and 11.2% without triggering. Repeated measurements at different occasions showed a CV of 8.8%. Comparing measured with real flow in the phantom, the triggered differed 4.9% and the nontriggered 8.3%. Conclusion: The findings of this study demonstrate that pcMRI is a reliable method to measure total CBF in terms of both accuracy and reproducibility. J. Magn. Reson. Imaging 2002;16:1–5. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Validation of a one-dimensional model of the systemic arterial tree
Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00037.2009 · Cited by 638
Cerebral Perfusion and the Risk of Dementia: A Population-Based Study
Wolters, F. J., Zonneveld, H. I., Hofman, A., van der Lugt, A., Koudstaal, P. J., Vernooij, M. W., & Ikram, M. A. (2017) · Circulation · doi:10.1161/circulationaha.117.027448 · Cited by 520
Blood Flow Distribution in Cerebral Arteries
Zarrinkoob, L., Ambarki, K., Wåhlin, A., Birgander, R., Eklund, A., & Malm, J. (2015) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.241 · Cited by 365
Coverdale, N. S., Gati, J. S., Opalevych, O., Perrotta, A., & Shoemaker, J. K. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00285.2014 · Cited by 348
Brain and central haemodynamics and oxygenation during maximal exercise in humans
González‐Alonso, J., Dalsgaard, M. K., Osada, T., Volianitis, S., Dawson, E. A., Yoshiga, C. C., & Secher, N. H. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.060574 · Cited by 276
Metadata
- Authors
- Spilt, A., Box, F. M. A., van der Geest, R. J., Reiber, J. H. C., Kunz, P., Kamper, A. M., Blauw, G. J., & van Buchem, M. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2002-06-26
- Volume
- 16
- Issue
- 1
- Pages
- 1-5
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2074274705
- Cited by
- 158
- References
- 1
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging. https://app.cochat.ai/papers/10.1002/jmri.10133
- The paper
- Spilt, A., Box, F. M. A., van der Geest, R. J., Reiber, J. H. C., Kunz, P., Kamper, A. M., Blauw, G. J., & van Buchem, M. A. (2002). Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10133
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.