The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Validation of a one-dimensional model of the systemic arterial tree
Open accessAbstract
A distributed model of the human arterial tree including all main systemic arteries coupled to a heart model is developed. The one-dimensional (1-D) form of the momentum and continuity equations is solved numerically to obtain pressures and flows throughout the systemic arterial tree. Intimal shear is modeled using the Witzig-Womersley theory. A nonlinear viscoelastic constitutive law for the arterial wall is considered. The left ventricle is modeled using the varying elastance model. Distal vessels are terminated with three-element windkessels. Coronaries are modeled assuming a systolic flow impediment proportional to ventricular varying elastance. Arterial dimensions were taken from previous 1-D models and were extended to include a detailed description of cerebral vasculature. Elastic properties were taken from the literature. To validate model predictions, noninvasive measurements of pressure and flow were performed in young volunteers. Flow in large arteries was measured with MRI, cerebral flow with ultrasound Doppler, and pressure with tonometry. The resulting 1-D model is the most complete, because it encompasses all major segments of the arterial tree, accounts for ventricular-vascular interaction, and includes an improved description of shear stress and wall viscoelasticity. Model predictions at different arterial locations compared well with measured flow and pressure waves at the same anatomical points, reflecting the agreement in the general characteristics of the “generic 1-D model” and the “average subject” of our volunteer population. The study constitutes a first validation of the complete 1-D model using human pressure and flow data and supports the applicability of the 1-D model in the human circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684 · cited 2×
“Table 1 for review) for simulating wave propagation in the entire (2, 13) or parts of the arterial tree (6, 48, 50, 69) under various physiological (44, 50, 55, 70, 74) or pathological conditions (1, 3, 9, 36, 64, 71).”
BackgroundMethodStettler, J. C., Niederer, P., & Anliker, M. (1981) · Annals of Biomedical Engineering · doi:10.1007/bf02363533 · Cited by 107
Stettler, J. C., Niederer, P., Anliker, M., & Casty, M. (1981) · Annals of Biomedical Engineering · doi:10.1007/bf02363534 · Cited by 35
Cited by
Alastruey, J., Khir, A. W., Matthys, K. S., Segers, P., Sherwin, S. J., Verdonck, P. R., Parker, K. H., & Peiró, J. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.05.041 · Cited by 441
Fluid dynamics of cerebrospinal fluid flow in perivascular spaces
Thomas, J. H. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0572 · Cited by 155
Metadata
- Authors
- Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2009-07
- Volume
- 297
- Issue
- 1
- Pages
- H208-H222
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2148232499
- Cited by
- 638
- References
- 3
- FWCI
- 17.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of a one-dimensional model of the systemic arterial tree. https://app.cochat.ai/papers/10.1152/ajpheart.00037.2009
- The paper
- Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N. (2009). Validation of a one-dimensional model of the systemic arterial tree. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00037.2009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.