The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Cerebral blood flow velocity underestimates cerebral blood flow during modest hypercapnia and hypocapnia
Abstract
To establish the accuracy of transcranial Doppler ultrasound (TCD) measures of middle cerebral artery (MCA) cerebral blood flow velocity (CBFV) as a surrogate of cerebral blood flow (CBF) during hypercapnia (HC) and hypocapnia (HO), we examined whether the cross-sectional area (CSA) of the MCA changed during HC or HO and whether TCD-based estimates of CBFV were equivalent to estimates from phase contrast (PC) magnetic resonance imaging. MCA CSA was measured from 3T magnetic resonance images during baseline, HO (hyperventilation at 30 breaths/min), and HC (6% carbon dioxide). PC and TCD measures of CBFV were measured during these protocols on separate days. CSA and TCD CBFV were used to calculate CBF. During HC, CSA increased from 5.6 ± 0.8 to 6.5 ± 1.0 mm 2 ( P < 0.001, n = 13), while end-tidal carbon dioxide partial pressure (PetCO 2) increased from 37 ± 3 to 46 ± 5 Torr ( P < 0.001). During HO, CSA decreased from 5.8 ± 0.9 to 5.3 ± 0.9 mm 2 ( P < 0.001, n = 15), while PetCO 2 decreased from 36 ± 4 to 23 ± 3 Torr ( P < 0.001). CBFVs during baseline, HO, and HC were compared between PC and TCD, and the intraclass correlation coefficient was 0.83 ( P < 0.001). The relative increase from baseline was 18 ± 8% greater ( P < 0.001) for CBF than TCD CBFV during HC, and the relative decrease of CBF during HO was 7 ± 4% greater than the change in TCD CBFV ( P < 0.001). These findings challenge the assumption that the CSA of the MCA does not change over modest changes in PetCO 2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical power analyses using G∗Power 3.1: tests for correlation and regression analyses
Faul, F., Erdfelder, E., Buchner, A., & Lang, A.-G. (2009) · Behavior Research Methods · doi:10.3758/brm.41.4.1149 · Cited by 37,615
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101995 · Cited by 1,827
MRI Measures of Middle Cerebral Artery Diameter in Conscious Humans During Simulated Orthostasis
Serrador, J. M., Picot, P. A., Rutt, B. K., Shoemaker, J. K., & Bondar, R. L. (2000) · Stroke · doi:10.1161/01.str.31.7.1672 · Cited by 717
Self-citationCerebral Arterial Diameters during Changes in Blood Pressure and Carbon Dioxide during Craniotomy
Giller, C. A., Bowman, G., Dyer, H., Mootz, L., & Krippner, W. (1993) · Neurosurgery · doi:10.1227/00006123-199305000-00006 · Cited by 659
Regional brain blood flow in man during acute changes in arterial blood gases
Willie, C. K., Macleod, D. B., Shaw, A. D., Smith, K. J., Tzeng, Y. C., Eves, N. D., Ikeda, K., Graham, J., Lewis, N. C., Day, T. A., et al. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.228551 · Cited by 483
Miyazaki, M., & Lee, V. S. (2008) · Radiology · doi:10.1148/radiol.2481071497 · Cited by 407
Wilson, M. H., Edsell, M. E., Davagnanam, I., Hirani, S. P., Martin, D. S., Levett, D. Z., Thornton, J. S., Golay, X., Strycharczuk, L., Newman, S. P., et al. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.81 · Cited by 226
Valdueza, J. M., Balzer, J. O., Villringer, A., Vogl, T. J., Kutter, R., & Einhäupl, K. M. (1997) · PubMed Central · Cited by 216
Cited by
Neurovascular coupling in humans: Physiology, methodological advances and clinical implications
Phillips, A. A., Chan, F. H., Zheng, M. M. Z., Krassioukov, A. V., & Ainslie, P. N. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x15617954 · Cited by 481
Regulation of cerebral blood flow and metabolism during exercise
Smith, K. J., & Ainslie, P. N. (2017) · Experimental Physiology · doi:10.1113/ep086249 · Cited by 327
Verbree, J., Bronzwaer, A.-S. G. T., Ghariq, E., Versluis, M. J., Daemen, M. J. A. P., van Buchem, M. A., Dahan, A., van Lieshout, J. J., & van Osch, M. J. P. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00651.2014 · Cited by 303
Korad, S., Mündel, T., & Perry, B. G. (2024) · Experimental Physiology · doi:10.1113/ep091707 · Cited by 8
Metadata
- Authors
- Coverdale, N. S., Gati, J. S., Opalevych, O., Perrotta, A., & Shoemaker, J. K.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2014-11-15
- Volume
- 117
- Issue
- 10
- Pages
- 1090-1096
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2110016913
- Cited by
- 348
- References
- 25
- FWCI
- 23.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cerebral blood flow velocity underestimates cerebral blood flow during modest hypercapnia and hypocapnia. https://app.cochat.ai/papers/10.1152/japplphysiol.00285.2014
- The paper
- Coverdale, N. S., Gati, J. S., Opalevych, O., Perrotta, A., & Shoemaker, J. K. (2014). Cerebral blood flow velocity underestimates cerebral blood flow during modest hypercapnia and hypocapnia. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00285.2014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.