The DOI matches its Crossref record.
Multipoint dixon technique for water and fat proton and susceptibility imaging
Abstract
Extensions to a previously described three‐point Dixon magnetic resonance imaging technique are presented that use alternative water/fat phase‐encoding strategies. The technique is generalized to phase encoding of (−θ,0,θ) or (0,θ,2θ) radians, and the signal‐to‐noise ratio (S/N) performance is evaluated. It was found that a θ of 2π/3 radians has optimal S/N but that a θ of π radians is a good compromise and that phase encoding of (O,π, 2π) radians offer an advantage over the previous method, which used (−π, O, π) increments, in that a T2′ (intravoxel susceptibility dephasing) image may be obtained in addition to the usual water, fat, and B 0 images. A new four‐point method with phase encoding of (O, π, 2π, 3π) radians that can also provide a measure of the spectral width of the fat resonance is suggested. The disadvantages of the method are the extra imaging time and low S/N efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Liu, C., Li, W., Tong, K. A., Yeom, K. W., & Kuzminski, S. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24768 · Cited by 503
Breast Tissue Composition and Susceptibility to Breast Cancer
Boyd, N. F., Martin, L. J., Bronskill, M., Yaffe, M. J., Duric, N., & Minkin, S. (2010) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djq239 · Cited by 478
Tongue Fat and its Relationship to Obstructive Sleep Apnea
Kim, A. M., Keenan, B. T., Jackson, N., Chan, E. L., Staley, B., Poptani, H., Torigian, D. A., Pack, A. I., & Schwab, R. J. (2014) · Sleep · doi:10.5665/sleep.4072 · Cited by 394
Metadata
- Authors
- Glover, G. H.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 1
- Issue
- 5
- Pages
- 521-530
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2057784154
- Cited by
- 405
- References
- 0
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multipoint dixon technique for water and fat proton and susceptibility imaging. https://app.cochat.ai/papers/10.1002/jmri.1880010504
- The paper
- Glover, G. H. (1991). Multipoint dixon technique for water and fat proton and susceptibility imaging. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880010504
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.