Multipoint dixon technique for water and fat proton and susceptibility imaging
Abstract
Extensions to a previously described three‐point Dixon magnetic resonance imaging technique are presented that use alternative water/fat phase‐encoding strategies. The technique is generalized to phase encoding of (−θ,0,θ) or (0,θ,2θ) radians, and the signal‐to‐noise ratio (S/N) performance is evaluated. It was found that a θ of 2π/3 radians has optimal S/N but that a θ of π radians is a good compromise and that phase encoding of (O,π, 2π) radians offer an advantage over the previous method, which used (−π, O, π) increments, in that a T2′ (intravoxel susceptibility dephasing) image may be obtained in addition to the usual water, fat, and B 0 images. A new four‐point method with phase encoding of (O, π, 2π, 3π) radians that can also provide a measure of the spectral width of the fat resonance is suggested. The disadvantages of the method are the extra imaging time and low S/N efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Self-citationSchneider, E., & Glover, G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180208 · Cited by 221
Self-citationMultisection fat-water imaging with chemical shift selective presaturation.
Keller, P. J., Hunter, W. W., & Schmalbrock, P. (1987) · Radiology · doi:10.1148/radiology.164.2.3602398 · Cited by 146
In vivo Quantitative characterization of trabecular bone by NMR
Ford, J. C., & Wehrli, F. W. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170225 · Cited by 95
Cited by
Assessment of Hepatic Fibrosis With Magnetic Resonance Elastography
Yin, M., Talwalkar, J. A., Glaser, K. J., Manduca, A., Grimm, R. C., Rossman, P. J., Fidler, J. L., & Ehman, R. L. (2007) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.06.012 · Cited by 948
Schwenzer, N. F., Springer, F., Schraml, C., Stefan, N., Machann, J., & Schick, F. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.05.023 · Cited by 749
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Dixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
MRI of the tumor microenvironment
Gillies, R. J., Raghunand, N., Karczmar, G. S., & Bhujwalla, Z. M. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10181 · Cited by 550
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Liu, C., Li, W., Tong, K. A., Yeom, K. W., & Kuzminski, S. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24768 · Cited by 503
Breast Tissue Composition and Susceptibility to Breast Cancer
Boyd, N. F., Martin, L. J., Bronskill, M., Yaffe, M. J., Duric, N., & Minkin, S. (2010) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djq239 · Cited by 478
Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Multiecho reconstruction for simultaneous water‐fat decomposition and T2* estimation
Yu, H., McKenzie, C. A., Shimakawa, A., Vu, A. T., Brau, A. C. S., Beatty, P. J., Pineda, A. R., Brittain, J. H., & Reeder, S. B. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21090 · Cited by 437
Tongue Fat and its Relationship to Obstructive Sleep Apnea
Kim, A. M., Keenan, B. T., Jackson, N., Chan, E. L., Staley, B., Poptani, H., Torigian, D. A., Pack, A. I., & Schwab, R. J. (2014) · Sleep · doi:10.5665/sleep.4072 · Cited by 394
Relaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394
Fat and water magnetic resonance imaging
Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21895 · Cited by 372
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
Water–fat separation with IDEAL gradient‐echo imaging
Reeder, S. B., McKenzie, C. A., Pineda, A. R., Yu, H., Shimakawa, A., Brau, A. C., Hargreaves, B. A., Gold, G. E., & Brittain, J. H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20831 · Cited by 357
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320
Imaging-based Quantification of Hepatic Fat: Methods and Clinical Applications
Ma, X., Holalkere, N.-S., R, A. K., Mino-Kenudson, M., Hahn, P. F., & Sahani, D. V. (2009) · RadioGraphics · doi:10.1148/rg.295085186 · Cited by 312
Hepatic Fat Fraction: MR Imaging for Quantitative Measurement and Display—Early Experience
Hussain, H. K., Chenevert, T. L., Londy, F. J., Gulani, V., Swanson, S. D., McKenna, B. J., Appelman, H. D., Adusumilli, S., Greenson, J. K., & Conjeevaram, H. S. (2005) · Radiology · doi:10.1148/radiol.2373041639 · Cited by 277
Fatty Liver Disease: MR Imaging Techniques for the Detection and Quantification of Liver Steatosis
Cassidy, F. H., Yokoo, T., Aganovic, L., Hanna, R. F., Bydder, M., Middleton, M. S., Hamilton, G., Chavez, A. D., Schwimmer, J. B., & Sirlin, C. B. (2009) · RadioGraphics · doi:10.1148/rg.291075123 · Cited by 271
Characterisation of liver fat in the UK Biobank cohort
Wilman, H. R., Kelly, M., Garratt, S., Matthews, P. M., Milanesi, M., Herlihy, A., Gyngell, M., Neubauer, S., Bell, J. D., Banerjee, R., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0172921 · Cited by 159
Intramuscular adipose tissue and central activation in older adults
Yoshida, Y., Marcus, R. L., & Lastayo, P. C. (2012) · Muscle & Nerve · doi:10.1002/mus.23506 · Cited by 90
“lean tissue and IMAT percent composition of the thigh were analyzed using the three-point Dixon method.(25) This method accurately measures respective lean tissue and IMAT CSA (cm(2)).”
Method
Metadata
- Authors
- Glover, G. H.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 1
- Issue
- 5
- Pages
- 521-530
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2057784154
- Cited by
- 405
- References
- 7
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.