The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Phase I clinical evaluation of a new iron oxide MR contrast agent
Abstract
The safety and magnetic resonance (MR) imaging potential of BMS 180549, a new superparamagnetic iron oxide contrast agent, were evaluated in a phase I, open‐label, placebo‐controlled study involving 41 healthy subjects. No clinically significant postdose changes in physical examination findings, vital signs, or electrocardiogram results were reported for any of the subjects evaluated. No clinically significant changes in clinical laboratory values were noted by the investigators. Fourteen adverse events considered not serious and considered possibly or definitely related to the drug were reported, three of which required minor treatment. Relaxation time measurements in plasma samples showed a strong, dose‐dependent, and persistent decrease in T1 and T2 values. Significant changes in MR signal intensity of the blood pool and wellperfused organs (liver and spleen) were noted on both T1‐ and T2‐weighted images. Changes in signal intensity of cervical lymph nodes were also observed at the higher doses and late postdose imaging times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marchal, G., Van Hecke, P., Demaerel, P., Decrop, E., Kennis, C., Baert, A., & van der Schueren, E. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.4.771 · Cited by 122
Cited by
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Clinical Translation of Nanomedicine
Min, Y., Caster, J. M., Eblan, M. J., & Wang, A. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00116 · Cited by 772
Characterization of aqueous dispersions of Fe3O4 nanoparticles and their biomedical applications
Cheng, F.-Y., Su, C.-H., Yang, Y.-S., Yeh, C.-S., Tsai, C.-Y., Wu, C.-L., Wu, M.-T., & Shieh, D.-B. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.016 · Cited by 668
Metadata
- Authors
- McLachlan, S. J., Morris, M. R., Lucas, M. A., Fisco, R. A., Eakins, M. N., Fowler, D. R., Scheetz, R. B., & Olukotun, A. Y.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1994-05
- Volume
- 4
- Issue
- 3
- Pages
- 301-307
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1981616235
- Cited by
- 194
- References
- 1
- FWCI
- 6.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phase I clinical evaluation of a new iron oxide MR contrast agent. https://app.cochat.ai/papers/10.1002/jmri.1880040313
- The paper
- McLachlan, S. J., Morris, M. R., Lucas, M. A., Fisco, R. A., Eakins, M. N., Fowler, D. R., Scheetz, R. B., & Olukotun, A. Y. (1994). Phase I clinical evaluation of a new iron oxide MR contrast agent. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880040313
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.