The DOI matches its Crossref record.
Reduction of partial‐volume artifacts with zero‐filled interpolation in three‐dimensional MR angiography
Abstract
Partial‐volume artifacts reduce vessel contrast and continuity (especially in small vessels) in magnetic resonance (MR angiography. The authors applied zero‐filled (band‐limited) interpolation to three‐dimensional (3D) MR angiograms to reduce partial‐volume artifacts. They demonstrated that zero‐filled interpolation can also be implemented by means of voxel shifting in real space. Voxel‐shifted interpolation is much less computer memory intensive than conventional zero‐filled interpolation. They numerically simulated the contrast loss due to partial‐volume artifacts and contrast recovery obtained with zero‐filled interpolation. Zero‐filled interpolation in all three orthogonal directions was applied to 3D MR angiography data sets from 29 human studies. These studies were obtained with the three commonly used 3D MR angiography techniques: 3D time of flight, multislab 3D time of flight, and 3D phase contrast. A substantial improvement in vessel contrast and vessel continuity was observed in all cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Gerig, G., & Kikinis, R. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80009-1 · Cited by 1,163
Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se34876 · Cited by 538
Yuan, C., Mitsumori, L. M., Beach, K. W., & Maravilla, K. R. (2001) · Radiology · doi:10.1148/radiol.2212001612 · Cited by 455
Super‐resolution musculoskeletal MRI using deep learning
Chaudhari, A. S., Fang, Z., Kogan, F., Wood, J., Stevens, K. J., Gibbons, E. K., Lee, J. H., Gold, G. E., & Hargreaves, B. A. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27178 · Cited by 406
Metadata
- Authors
- Du, Y. P., Parker, D. L., Davis, W. L., & Cao, G.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1994-09
- Volume
- 4
- Issue
- 5
- Pages
- 733-741
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2050789214
- Cited by
- 216
- References
- 0
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduction of partial‐volume artifacts with zero‐filled interpolation in three‐dimensional MR angiography. https://app.cochat.ai/papers/10.1002/jmri.1880040517
- The paper
- Du, Y. P., Parker, D. L., Davis, W. L., & Cao, G. (1994). Reduction of partial‐volume artifacts with zero‐filled interpolation in three‐dimensional MR angiography. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880040517
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.