The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Abstract
PURPOSE: To compare a T1-weighted, three-dimensional (3D), gradient-echo (GRE) sequence for magnetic resonance (MR) imaging of the body (volumetric interpolated breath-hold examination, or VIBE) with a two-dimensional (2D) GRE breath-hold equivalent. MATERIALS AND METHODS: Twenty consecutive patients underwent 1.5-T MR imaging. The examinations included pre- and postcontrast (20 mL gadopentetate dimeglumine) fat-saturated 2D GRE breath-hold imaging and fat-saturated volumetric interpolated breath-hold imaging before, during (arterial phase), and after injection, with thin (2-mm source images) and thick (8-mm reconstruction images) sections. The three images were compared qualitatively and quantitatively (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]). RESULTS: Qualitatively, the 2-mm source images had poorer pancreatic edge definition on precontrast images compared with the other two data sets (P < .05). On gadolinium-enhanced images, scores for clarity of pancreatic edge, number of vessels visualized, and arterial ghosting were significantly lower for the postcontrast 2D GRE images. Quantitatively, SNR measurements in the liver, aorta, and renal cortex on pre- and postcontrast images were significantly higher for the 8-mm reconstruction images than for the 2D GRE or 2-mm source images (P < .05). Aorta-to-fat CNR was significantly higher on the 8-mm reconstruction images. CONCLUSION: Fat-saturated volumetric interpolated breath-hold images have quality comparable to that of conventional fat-saturated 2D GRE images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Three-Dimensional MR Imaging Using the FLASH Technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198603000-00046 · Cited by 267
Du, Y. P., Parker, D. L., Davis, W. L., & Cao, G. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040517 · Cited by 216
Hamm, B., Thoeni, R. F., Gould, R. G., Bernardino, M. E., Lüning, M., Saini, S., Mahfouz, A. E., Taupitz, M., & Wolf, K. J. (1994) · Radiology · doi:10.1148/radiology.190.2.8284392 · Cited by 204
Peterson, M. S., Baron, R. L., & Murakami, T. (1996) · Radiology · doi:10.1148/radiology.201.2.8888220 · Cited by 138
Mitchell, D. G., Vinitski, S., Saponaro, S., Tasciyan, T. A., Burk, D. L., & Rifkin, M. D. (1991) · Radiology · doi:10.1148/radiology.178.1.1984328 · Cited by 113
Segmental anatomy of the liver: poor correlation with CT.
Fasel, J. H. D., Selle, D., Evertsz, C. J. G., Terrier, F., Peitgen, H. O., & Gailloud, P. (1998) · Radiology · doi:10.1148/radiology.206.1.9423665 · Cited by 104
Shirkhoda, A., Konez, O., Shetty, A. N., Bis, K. G., Ellwood, R. A., & Kirsch, M. J. (1997) · Radiology · doi:10.1148/radiology.202.1.8988220 · Cited by 75
Soyer, P. A., Bluemke, D. A., Bliss, D., Woodhouse, C., & Fishman, E. K. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.163.1.8010258 · Cited by 64
Soyer, P. A., de Givry, S. C., Gueye, C., Lenormand, S., Somveille, E., & Scherrer, A. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.5.8615254 · Cited by 61
Hepatic neoplasms: surgically relevant segmental anatomy and imaging techniques.
Gazelle, G. S., & Haaga, J. R. (1992) · American Journal of Roentgenology · doi:10.2214/ajr.158.5.1566658 · Cited by 45
Cited by
Libri, V., Brown, A. P., Gambarota, G., Haddad, J., Shields, G. S., Dawes, H., Pinato, D. J., Hoffman, E., Elliot, P. J., Vlasuk, G. P., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0051395 · Cited by 135
Fischer, M. A., Pfirrmann, C. W. A., Espinosa, N., Raptis, D. A., & Buck, F. M. (2014) · European Radiology · doi:10.1007/s00330-014-3121-1 · Cited by 112
Metadata
- Authors
- Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C.
- Venue
- Radiology
- Published
- 1999-09
- Volume
- 212
- Issue
- 3
- Pages
- 876-884
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2107061083
- Cited by
- 538
- References
- 11
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination. https://app.cochat.ai/papers/10.1148/radiology.212.3.r99se34876
- The paper
- Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C. (1999). Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination. Radiology. https://doi.org/10.1148/radiology.212.3.r99se34876
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.