Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 538

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination

Rofsky, Neil M., Lee, Vivian S., Laub, Gerhard, Pollack, Michael A., Krinsky, Glenn A., Thomasson, David, Ambrosino, Michael M., Weinreb, Jeffrey C.·1999·Radiology

Abstract

PURPOSE: To compare a T1-weighted, three-dimensional (3D), gradient-echo (GRE) sequence for magnetic resonance (MR) imaging of the body (volumetric interpolated breath-hold examination, or VIBE) with a two-dimensional (2D) GRE breath-hold equivalent. MATERIALS AND METHODS: Twenty consecutive patients underwent 1.5-T MR imaging. The examinations included pre- and postcontrast (20 mL gadopentetate dimeglumine) fat-saturated 2D GRE breath-hold imaging and fat-saturated volumetric interpolated breath-hold imaging before, during (arterial phase), and after injection, with thin (2-mm source images) and thick (8-mm reconstruction images) sections. The three images were compared qualitatively and quantitatively (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]). RESULTS: Qualitatively, the 2-mm source images had poorer pancreatic edge definition on precontrast images compared with the other two data sets (P < .05). On gadolinium-enhanced images, scores for clarity of pancreatic edge, number of vessels visualized, and arterial ghosting were significantly lower for the postcontrast 2D GRE images. Quantitatively, SNR measurements in the liver, aorta, and renal cortex on pre- and postcontrast images were significantly higher for the 8-mm reconstruction images than for the 2D GRE or 2-mm source images (P < .05). Aorta-to-fat CNR was significantly higher on the 8-mm reconstruction images. CONCLUSION: Fat-saturated volumetric interpolated breath-hold images have quality comparable to that of conventional fat-saturated 2D GRE images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.212.3.r99se34876

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 538

Metadata

Authors
Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C.
Venue
Radiology
Published
1999-09
Volume
212
Issue
3
Pages
876-884
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2107061083
Cited by
538
References
11
FWCI
14.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination. https://app.cochat.ai/papers/10.1148/radiology.212.3.r99se34876
The paper
Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C. (1999). Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination. Radiology. https://doi.org/10.1148/radiology.212.3.r99se34876

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.