Determination of wall shear stress in the aorta with the use of MR phase velocity mapping
The DOI matches its Crossref record.
Abstract
MR phase velocity mapping was used to calculate wall shear stress (WSS) in the suprarenal and infrarenal abdominal aorta, two sites with very different proclivities for development of atherosclerosis. For the eight subjects studied, the average value of the mean (tune averaged over the cardiac cycle) WSS in the suprarenal aorta was 10.4 dynes/cm 2 at the posterior wall and 8.6 at the anterior wall. In the infrarenal aorta, WSS values were 4.7 at the posterior wall and 6.1 at the anterior wall. Peak WSS over the cardiac cycle was 48 and 54 at the anterior and posterior walls of the suprarenal aorta, respectively, and 33 and 30 at the anterior and posterior walls of the infrarenal aorta, respectively. Wide variation was found in both mean and peak WSS values among subjects. However, for 28 of 32 locations examined, mean and peak WSS were ingher in the suprarenal aorta than in the infrarenal aorta. Because atherosclerosis is more likely to form in the infrarenal aorta than in the suprarenal aorta, tins study supports the hypothesis that low WSS is a localizing factor for atherosclerosis, and ingh WSS may act as a deterrent against formation of atherosclerosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hemodynamic shear stress and its role in atherosclerosis
Malek, A. M. (1999) · JAMA · doi:10.1001/jama.282.21.2035 · Cited by 3,650
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Markl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463
Role of hemodynamic shear stress in cardiovascular disease
Cecchi, E., Giglioli, C., Valente, S., Lazzeri, C., Gensini, G. F., Abbate, R., & Mannini, L. (2011) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2010.09.008 · Cited by 404
Wall Shear Stress: Theoretical Considerations and Methods of Measurement
Katritsis, D., Kaiktsis, L., Chaniotis, A., Pantos, J., Efstathopoulos, E. P., & Marmarelis, V. (2007) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2006.11.001 · Cited by 346
E XPERIMENTAL AND C OMPUTATIONAL M ETHODS IN C ARDIOVASCULAR F LUID M ECHANICS
Taylor, C. A., & Draney, M. T. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121944 · Cited by 285
Milner, J. S., Moore, J. A., Rutt, B. K., & Steinman, D. A. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70210-1 · Cited by 276
Frydrychowicz, A., Stalder, A. F., Russe, M. F., Bock, J., Bauer, S., Harloff, A., Berger, A., Langer, M., Hennig, J., & Markl, M. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21790 · Cited by 180
Volumetric arterial wall shear stress calculation based on cine phase contrast MRI
Potters, W. V., van Ooij, P., Marquering, H., vanBavel, E., & Nederveen, A. J. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24560 · Cited by 177
“The availability of volumetric 3D WSS information is an improvement over existing 2D and slice-based WSS calculation methods (14,17).”
Method4D MR phase and magnitude segmentations with GPU parallel computing
Bergen, R. V., Lin, H.-Y., Alexander, M. E., & Bidinosti, C. P. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.08.019 · Cited by 11
“Other hemodynamic parameters such as pressure differences and vessel wall shear stress can also be calculated [7–11].”
Background
Metadata
- Authors
- Osinnski, J. N., Ku, D. N., Mukundan, S., Loth, F., & Pettigrew, R. I.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1995-11
- Volume
- 5
- Issue
- 6
- Pages
- 640-647
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2008686201
- Cited by
- 174
- References
- 0
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.