Abstract
Purpose: To assess the accuracy and precision of a volumetric wall shear stress (WSS) calculation method applied to cine phase contrast magnetic resonance imaging (PC‐MRI) data. Materials and Methods: Volumetric WSS vectors were calculated in software phantoms. WSS algorithm parameters were optimized and the influence of spatial resolution and segmentation was evaluated. Subsequently, 2D cine PC‐MRI data in the carotid and the aorta at varying spatial resolutions were obtained (n = 2) and compared with the simulations. Finally, volumetric WSS was calculated in 3D cine PC‐MRI data of the carotid bifurcation and the aorta (n = 6). Results: We found that at least 8 voxels across the diameter are required to obtain a WSS accuracy of 5% and a precision of 20% in software phantoms. Systematic WSS quantification errors up to 40% were found in the case of segmentation errors. The in vivo measurements using 2D cine PC‐MRI exhibited WSS increase at increasing spatial resolutions, similar to the results in software phantoms. Volumetric WSS vectors were successfully calculated in three healthy carotid bifurcations and aortas. Conclusion: The effects of resolution and segmentation on the accuracy and precision of the WSS algorithm were quantified. We were able to calculate volumetric WSS in the carotid bifurcation and the aorta. J. Magn. Reson. Imaging 2015;41:505–516.© 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868 · cited 1×
“The segmentations of 3D cine PC-MRI data in systole (created using the active contour evolution algorithm in ITK-SNAP (26)) were filtered with a Laplacian filter (27) to reduce irregularities and discretization effects and the results were manually checked by overlaying them on all image types (velocity, magnitude ima…”
MethodSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 2×
“Another limitation can be the use of parallel imaging (SENSE), which may decrease the SNR (42).”
BackgroundHemodynamic shear stress and its role in atherosclerosis
Malek, A. M. (1999) · JAMA · doi:10.1001/jama.282.21.2035 · Cited by 3,650 · cited 1×
“High WSS is believed to be a stimulus for physiological remodeling of the blood vessel wall and for maintaining an atheroprotective phenotype (4).”
BackgroundThe rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494 · cited 1×
“Additionally, noise (normal distribution, the variance set to 10% of the venc (22,23)) was added to investigate its effect on WSS estimates.”
MethodChiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280 · cited 1×
“THE EFFECT OF BLOOD FLOW on the vascular endothelium has been proposed to be a critical determinant of vascular disease progression in atherosclerosis and aneurysms (1,2).”
BackgroundReinsch, C. H. (1967) · Numerische Mathematik · doi:10.1007/bf02162161 · Cited by 2,236
Chatzizisis, Y. S., Coskun, A. U., Jonas, M., Edelman, E. R., Feldman, C. L., & Stone, P. H. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.059 · Cited by 1,483
Li, C., Huang, R., Ding, Z., Gatenby, J. C., Metaxas, D. N., & Gore, J. C. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2146190 · Cited by 1,285 · cited 1×
“A 2D level set evolution algorithm (25) was used to segment the lumen for each transversal slice in the high-resolution 2D cine PC-MRI datasets during systole.”
MethodMeng, H., Tutino, V. M., Xiang, J., & Siddiqui, A. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3558 · Cited by 955
Phase contrast cine magnetic resonance imaging.
Pelc, N. J., Herfkens, R. J., Shimakawa, A. S., & Enzmann, D. R. (1991) · PubMed · Cited by 610
Cited by
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Metadata
- Authors
- Potters, W. V., van Ooij, P., Marquering, H., vanBavel, E., & Nederveen, A. J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2014-01-17
- Volume
- 41
- Issue
- 2
- Pages
- 505-516
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2137913387
- Cited by
- 177
- References
- 37
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volumetric arterial wall shear stress calculation based on cine phase contrast MRI. https://app.cochat.ai/papers/10.1002/jmri.24560
- The paper
- Potters, W. V., van Ooij, P., Marquering, H., vanBavel, E., & Nederveen, A. J. (2015). Volumetric arterial wall shear stress calculation based on cine phase contrast MRI. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.24560
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.